GE APPLIANCES JGP3530SLSS 30 Inch Built-In Gas Cooktop Instruction Manual
- June 9, 2024
- GE Appliances
Table of Contents
- GE APPLIANCES JGP3530SLSS 30 Inch Built-In Gas Cooktop
- WARNING
- FOR YOUR SAFETY
- TOOLS YOU WILL NEED
- BEFORE YOU BEGIN
- DIMENSIONS AND CLEARANCES
- INSTALLING THE COOKTOP
- GAS SUPPLY
- ELECTRICAL CONNECTIONS
- SURFACE BURNERS
- CHECK SURFACE BURNERS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GE APPLIANCES JGP3530SLSS 30 Inch Built-In Gas Cooktop
WARNING
FIRE OR EXPLOSION HAZARD
If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Installation must be performed by a qualified installer. Read these
instructions completely and carefully. Installation of this product must
conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/ NFPA.54, latest edition. In Canada, installation
must conform with the current Natural Gas Installation Code, CAN/CGA-B149.1 or
the current Propane Installation Code, CAN/CGAB149.2, and with local codes
where applicable. This product has been design-certified by UL according to
ANSI Z21.1, latest edition and Canadian Gas Association according to CAN/
CGA-1.1 latest edition. When installing a gas appliance the use of old
flexible connectors can cause gas leaks and personal injury. Always use a NEW
flexible connector. Leak testing of the appliance shall be conducted
according to the manufacturer instructions.The cooktop must be electrically
grounded in accordance with local codes or, in the absence of local codes, in
accordance with the National Electrical Code (ANSI/NFPA 70, latest edition).
In Canada, electrical grounding must be in accordance with the current CSA
C22.1 Canadian Electrical Code Part 1 and/or local codes. See Electrical
Connections in this section. Do not install this product with an air curtain
hood or other cooktop hood that operates by blowing air down on the cooktop.
This airflow may interfere with operation of the gas burners resulting in fire
or explosion hazard.
FOR YOUR SAFETY
WARNING Before beginning the installation, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
TOOLS YOU WILL NEED
MATERIALS YOU MAY NEED
- Gas line shut-off valve
- Pipe joint sealant or UL-approved pipe thread tape with Teflon* that resists action of natural and propane gases.
- Flexible metal appliance connector (1/2” I.D.). A 5-foot length is recommended for ease of installation but other lengths are acceptable. Never use an old connector when installing a new cooktop.
- Flare union adapter for connection to gas supply line (3/4” or 1/2” NPT x 1/2” I.D.).
- Flare union adapter for connection to pressure regulator on cooktop (1/2” NPT x 1/2” I.D.).
- Liquid leak detector or soapy water.
- Foam tape
- Teflon: Registered trademark of DuPont
BEFORE YOU BEGIN
IMPORTANT — Save these instructions for local inspector’s use.
IMPORTANT — Observe all governing codes and ordinances.
IMPORTANT — Remove all packing material and literature before connecting
gas and electrical supply to cooktop.
IMPORTANT — To avoid damage to your cabinets, check with your builder or
cabinet supplier to make sure that the materials used will not discolor,
delaminate or sustain other damage. This product has been designed in
accordance with the requirements of UL and CSA International and complies with
the maximum allowable wood cabinet temperatures of 194°F (90°C).
- Note to Installer – Be sure to leave these instructions with consumer.
- Note to consumer – Keep these instructions for future reference.
- Servicer – The electrical diagram is in an envelope attached to the back of the cooktop. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under warranty.
- Mobile Home – Additional Installation Requirements
The installation of this product must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Saftey, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this product must conform with the current standards CAN/CSAA240-latest edition, or with local codes. When this cooktop is installed in a mobile home, it must be secured during transit. Any method of securing the cooktop is adequate as long as it conforms to the standards listed above.
DIMENSIONS AND CLEARANCES
- Provide adequate clearances between the cooktop and adjacent combustible surfaces.
- These dimensions must be met for safe use of your cooktop.
- Allow 30” (76.2 cm) minimum clearance between burners and bottom of unprotected wood or metal cabinet, or allow a 24” (61 cm) minimum when bottom of wood or metal cabinet is protected by no less than 1/4” (6.4 mm) thick flame-retardant millboard covered with no less than No. 28 MSG sheet metal (.015” [.38 mm] thick), .015” (.38 mm) thick stainless steel, .025” (0.64 mm) aluminum or .020” (0.5 mm) copper.
- Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.
- Built-in oven installation, shall conform to the installation instruction packed with the built-in oven.
MAINTAIN THE FOLLOWING MINIMUM CLEARANCE DIMENSIONS
NOTE: Allow 7/16” minimum vertical clearance from the cooktop bottom (or
3-11/16” minimum depth from the countertop) to any combustible surfaces, such
as a cabinet drawer.
For island installation, maintain 2-1/2 in. minimum from cutout to front and
back edge of countertop. Maintain 3 in. minimum from cutout to side edges of
countertop.
OVERALL COOKTOP DIMENSIONS
CUTOUT DIMENSIONS OF COUNTERTOP
To ensure accuracy, it is best to make a template when cutting the opening in
the counter.
RECOMMENDED GAS SUPPLY LOCATION FROM BACKWALL
FOR AMERICANS WITH DISABILITIES ACT (ADA) FORWARD APPROACH INSTALLATION
ONLY
NOTE: The enclosure must be made of wood material. Also, an access panel
is required for the electrical outlet, pressure regulator, shut-off valve,
hold-down brackets, and service.
CONVERTING TO PROPANE GAS (OR CONVERTING BACK TO NATURAL GAS FROM
PROPANE)
This cooktop leaves the factory set for use with natural gas. If you want to
convert to propane gas, the conversion must be performed by a qualified
propane gas installer. The conversion orifices and instructions can be found
attached to the regulator. Keep these instructions and all orifices in case
you want to convert back to natural gas.
INSTALLING THE COOKTOP
- A. Locate electrical outlet and gas shut-off valve beneath cabinet.
- B. Lay cooktop upside down on a towel or tablecloth covered countertop.
- C. Apply foam tape around the outer edge of the glass. Do not overlap the foam tapes.
- D. Locate and remove hold-down brackets from literature package.
- E. Attach brackets to cooktop. Remove the screw from the side of the cooktop and screw the hold-down bracket to the side of the cooktop unit. Repeat for opposite side of cooktop.
- F. Insert the cooktop centered into the cutout opening. Make sure the front edge of the countertop is parallel to the cooktop. Make final check that all required clearances are met.
Once the unit is in place, screw the holddown bracket into the cabinet sides to secure the unit into place.
GAS SUPPLY
WARNING Fire Hazard: Do not use a flame to check for gas leaks.
WARNING Explosion Hazard: Do not exceed 25 ft-lbs of torque when making
gas line connections. Overtightening may crack the pressure regulator
resulting in fire or explosion hazard.
Gas Pressure Regulator
You must use the gas pressure regulator supplied with this range. For proper
operations the inlet pressure to the regulator should be as follows:
- Natural Gas:
- Minimum pressure: 5” of Water Column
- Maximum pressure: 13” of Water Column
- Propane Gas:
- Minimum pressure: 11” of Water Column
- Maximum pressure: 13” of Water Column
If you are not sure about the inlet pressure contact local gas supplier
Shut off the main gas supply valve before disconnecting the old cooktop and leave it off until the new hook-up has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on. Because hard piping restricts movement of the range, the use of a CSA International- certified flexible metal appliance connector is recommended unless local codes require a hard-piped connection. If the hard piping method is used, you must carefully align the pipe; the cooktop cannot be moved after the connection is made.
To prevent gas leaks, apply pipe joint compound or wrap pipe thread tape with Teflon* around all male (external) pipe threads
- A. Install provided regulator in the gas line between the cooktop and manual shut-off valve. Refer to the arrow on the back of the regulator for gas flow direction. Ensure the front of the regulator is facing towards the cabinet front, easily accessible through the cabinet doors.
- B. Install a manual shut-off valve in the gas line in a location easily accessible through the cabinet doors.
- C. When all connections have been made, ensure all gas controls are in the off position and turn on the main gas supply valve. Use a liquid leak detector at all joints and connections to check for leaks in the system
When using pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the cooktop and individual shut-off valve from the gas supply piping. When using pressures of 1/2 psig or less to pressure test the gas supply system, simply isolate the cooktop from the gas supply system by closing the individual shut-off valve. When checking for proper operation of the regulator, the inlet pressure must be at least 1” greater than the operating (manifold) pressure as given on rating label of product. *Teflon: Registered trademark of DuPont
CONNECTOR HOOKUP
TYPICAL INSTALLATION WITH NO OBSTRUCTION BELOW COOKTOP:
- A. 3/8” NPT male pipe thread
- B. Regulator provided with unit:
- Outlet – 3/8” NPT female pipe thread
- Inlet – 1/2” NPT female pipe thread
- C. Adapter
- D. Flexible connector
- E. Adapter
- F. Manual shut-off valve
- G. Gas pipe 1/2” or 3/4”
ALTERNATE INSTALLATION WITH OBSTRUCTION BELOW COOKTOP:
- A. 3/8” NPT male pipe thread
- B. Elbow
- C. Adapter
- D. Flexible connector (allows passage through cabinet wall)
- E. Adapter
- F. Regulator provided with unit:
- Outlet – 3/8” NPT female pipe thread
- Inlet – 1/2” NPT female pipe thread
- G. Gas pipe
- H. Manual shut-off valve
- I. Gas pipe 1/2” or 3/4”
ELECTRICAL CONNECTIONS
WARNING Shock Hazard: This appliance must be properly grounded. Failure to do so can result in electric shock.
Electrical Requirements – 120-volt, 60 Hertz, properly grounded circuit
protected by a 15-amp or 20-amp circuit breaker or time delay fuse. It is
recommended that a separate circuit serving only this cooktop be provided.
NOTE: Use of automatic, wireless, or wired external switches that shut
off power to the appliance are not recommended for this product.
Grounding
The power cord of this appliance is equipped with a three-prong (grounding)
plug which plugs into a standard three-prong grounding wall receptacle to
minimize the possibility of electric shock hazard from this appliance. The
customer should have the wall receptacle and circuit checked by a qualified
electrician to make sure the receptacle is properly grounded.
Where a standard two-prong wall receptacle is encountered, it is the personal
responsibility and obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM
THE POWER CORD. DO NOT USE AN ADAPTER. DO NOT USE AN EXTENSION CORD.
Ground Fault Circuit Interrupters (GFCI’s) are not required or recommended for
gas cooktop receptacles. Performance of the cooktop will not be affected if
operated on a GFCI-protected circuit but occasional nuisance tripping of the
GFCI breaker is possible.
SURFACE BURNERS
WARNING Fire or Explosion Hazard: Do not operate the burner without all burner parts in place.
- A. Burners – Place surface burners into corresponding positions on cooktop.
- B. Caps – Place caps on proper size burner.
- C. Grates – Place the grates on the cooktop.
CHECK SURFACE BURNERS
Push and turn a knob to the LITE position. A clicking sound indicates proper operation of the ignition system. When lighting any burner, sparks will appear at all burners but gas flows from only the one selected. Once air is purged from the supply line, burner should light within 4 seconds. After burner lights, rotate the knob out of the LITE position. Try each burner in succession until all burners have been checked.
Quality of Flames
Determine the quality of flames visually. Normal burner flames should look
like (A) or (B).
- (A) Soft blue flames— Normal for natural gas
- (B) Yellow tips on outer cones— Normal for propane gas
Long, bright yellow flames are not normal. Normal flames may show signs of an orange tint when well heated or signs of flickering orange due to particles in the gas or air.
WHEN ALL HOOKUPS ARE COMPLETED
Make sure all controls are left in the off position. Make sure the flow of
combustion and ventilation air to the cooktop is unobstructed. Check that all
packing materials and tape have been removed. This will include adhesive tape,
wire ties, cardboard and protective plastic. Failure to remove these materials
could result in damage to the appliance once the appliance has been turned on
and surfaces have heated.
INSTALLATION AT HIGH ALTITUDE
Over 6000ft, product configured for natural gas or propane requires
installation of kit (WB28X29863 for natural gas and WB28X29860 for propane
gas). Follow the instructions included with the kit.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>