PHILIPS RC530B TrueLine LED Panel Recessed Instruction Manual
- June 9, 2024
- Philips
Table of Contents
PHILIPS RC530B TrueLine LED Panel Recessed
Recessed
Lumen package| Lamp color| Optics| Driver| Power [W]
+/-1 0%
| Efficiency class| Lumen package| Lamp color| Op�cs| Driver| Power [W]
+/-1 0%
| Efficiency class
---|---|---|---|---|---|---|---|---|---|---|---
12/15/19/25/31/34/43| 930
940
| OC| POE| 9/10,4/13/17,1 21,5/24/30,8| D| 15/19/25/30/34/40/50| 930| OC| SRD|
11,6/14,2/18,8/23 25,5/30/31,5| E
17/40| 940| OC| POE| 12,2/28| 15| 940| OC| SRD| 11,2
12/17/19/25/30/34/40/43/50/68| 940| OC| PSD| 9,1/12,2/14/18,2/22
24,5/28,5/30,5/36/48,5| 19/38| 940| NOC| SRD| 17,2/33,5
31/38/62/86| 930
940
| OC| PSD| 22,5/27,5/45/61,5| 30/38/50/62| 940| NOC| PSD| 26,5/34/45/56
19/25/30/34/40/50| 940| OC| SRD| 13,4/17,6/22/24/28/35,5|
12/17/19/25/30/34/40/43/50/68| 930| OC| PSD| 9,6/12,8/14,8/19,2/23
26/30,5/32/38/51
31/38/43/62/68/86| 930
940
| OC| SRD| 22/27,5/30,8/43,8/48,8/62| 7/15| 930
940
| OC| PSD| 6,2/11,7
86| 940| ASSY| PSD| 63| 19| 930
940
| NOC| POE| 16,8
12|
930
940
| NOC| POE| 11,9| F| 17/40| 930| OC| POE| 13/30
7/12/15/19/25/31| NOC| PSD| 7,4/12,1/14,7/18,2/24,3/29,8| 15/25/31| 940| NOC|
POE| 13,2/22,5/28
15/25/30/31/50/62| NOC| SRD| 14,1/23,8/28,3/29,3/47,5/59| 34/40/43/50/68/80|
930
940
| ASSY| PSD| 26,8/32/33,5 39,5/53/62,5
19/38| 930| NOC| SRD| 18/35,5| 86| 930| ASSY| PSD| 67
30/38/50/62| NOC| PSD| 28/35,5/48/59| 15/19/25/30/31/34/38/40/43/50/62/68/86|
TW9| OC| SIA/DIA| 13,2/16,2/20/26,5/24,5/27,5 32,5/33/35,5/40,8/49/55/71
15/19/25/30/31/38/50/62| TW9| NOC| SIA/DIA| 16,4/20,5/27/32,5/34/41/54/68
Recessed VPC
Recessed PCV
![Recessed
PCV](https://manuals.plus/wp-content/uploads/2023/01/PHILIPS-RC530B-TrueLine- LED-Panel-Recessed-Instruction-Manual-7.png)
Recessed Line (VPC/PCV)
Recessed| Geometry| A
[mm]| B
[mm]| Sensor/Blind sensor cover|
---|---|---|---|---|---
VPC| W8L120| 1197| 1130| | 2,6
1170| •| 2,8
2,8
W8L125| 1247| 1130|
1170| •| 2,9
3,2
W8L150| 1497| 1410| •
1450| | 3,3
Recessed
|
Geometry
| A
[mm]| B
[mm]| Sensor/Blind sensor cover|
---|---|---|---|---|---
PCV
| W8L113| 1152| 1208| | 2,6
W8L117| 1192| 1248| •| 2,8
W8L141| 1432| 2052,2| | 3,1
W8L145| 1472| 2092,5| •| 3,4
Recessed| Geometry| A
[mm]| B
[mm]| Sensor/Blind sensor cover|
---|---|---|---|---|---
Line
VPC/PCV
| W8L113| 1127| –| | 2,5/2,7
W8L117| 1167| –| •| 2,7/2,9
W8L141| 1408| –| | 3/3,2
W8L145| 1448| –| •| 3,2/3,5
583 – 442710705443
© 04/2022, Signify Holding. All rights reserved.
Optinal:
RC530Z EP SET WH
![RC530Z
EP SET WH](https://manuals.plus/wp-content/uploads/2023/01/PHILIPS-RC530B- TrueLine-LED-Panel-Recessed-Instruction-Manual-11.png)
Recessed (add safety cable if required)
![Recessed
(add safety cable if required)](https://manuals.plus/wp-
content/uploads/2023/01/PHILIPS-RC530B-TrueLine-LED-Panel-Recessed-
Instruction-Manual-12.png)
![Recessed
(add safety cable if required)](https://manuals.plus/wp-
content/uploads/2023/01/PHILIPS-RC530B-TrueLine-LED-Panel-Recessed-
Instruction-Manual-13.png)
![Recessed
(add safety cable if required)](https://manuals.plus/wp- content/uploads/2023/01/PHILIPS-RC530B-TrueLine-LED-Panel-Recessed- Instruction-Manual-14.png)
Recessed Line
PI3, PI5 in line
Connect maximum 10 luminaires in a power cable.
The 11th luminaire should get the power from a new power cable. Don’t connect
it to the previous luminaire
Push-in (PIP) PSD/DIA
PI-5
Line End / Line Feature
PSD/DIA
PI5-PI2
Line End / Line Feature
Push-in (PIP) SRD/SIA
PI-3
Line End / Line Feature
PoE
Condition Philips to specify to the customers (instruction):
to use UTP (Unshielded Twisted Pair) CAT5E or CAT6 cable.
the maximum length of the cable to be 20 meters.
Apply a minimum radius of the Ethernet cable of 4x the cable diameter.
Minimal build-in dimensions for thermal insulation [mm]
|
Recessed
---|---
4ft| 5ft
Height| 120| 120
Width| 380| 380
Length| 1360| 1660
Cover remover (ZZS400 OCR)
Sensor upgrade procedure
-
Push and twist screwdriver in designated slot to click out the bracket, including the sensor
-
Once unlocked, take out sensor from the front
-
3/a Connect the new sensor to the wires and put it into the designated slot, click the bracket in
3/a If you use a blind cap instead of a sensor, insert the cable into the blind cap
Inrush current
Nr of drivers | 1 | 1 | 1 | 2 | 3 |
---|---|---|---|---|---|
Electrical characteristics | PSD | SRO | DIA/SIA | DIA/SIA | DIA/SIA |
I l max[A] | 25 | 21 | 29,6 | 59,2 | 45,6 |
Tref [µs] | 200 | 300 | 350 | 350 | 300 |
MCB Luminaire | PSD | SRO | DIA/SIA | DIA/SIA | DIA/SIA |
I B-4A | 5 | 5 | 4 | 1 | 2 |
B-6A | 8 | 8 | 6 | 2 | 4 |
B-10A | 12 | 13 | 10 | 4 | 6 |
8-13A | 16 | 17 | 13 | 5 | 8 |
I
8-16A
| 20| 21| 16| 6| 10
B-20A| 25| 26| 20| 8| 12 ·
I 8-25A| 31| 32| 25| 10| 15
B-32A| 40| 42| 32| 12| 20
8-40A| so| 52| 40| 15| 24
C-4A| 8| 9| 6| 2| 4
C-6A| 12| 13| 10| 4| 6
C-10A| 21| 22| 16| 6| 10
C-13A| 27| 28| 21| 8| 13
C-16A| 34| 35| 27| 10| 17
C-20A| 41| 43| 33| 13| 20
C-25A| 52| 54| 41| 16| 25
I C-32A| 68| 71| 54| 21| 33
C-40A| 83| 87| 66| 26| 41
Given the choices made in this unique lighting concept, there are a few instructions regarding the maintenance.
- Prevent water from entering on or in the luminaire at installation and during use of the luminaire
- During installation or maintaining the luminaire please use gloves to avoid spots on the cover.
- Do not clean with a dry cloth as it will cause the product to attract dust. Dirty spots can be removed: Only dust: use a damped cloth (no dripping water), preferably anti-static. Fingerprints etc: use a damped cloth (no dripping water) with a cleaner appropriate for polycarbonate/PMMA plastics.
- Do not touch electronic components as they are ESD sensitive.
- Do not stare into LED beam.
- Luminaire should not be used for illumination during building activities due to dust accumulation inside the luminaire.
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced
To get an overview of all spare parts for a luminaire, please refer to detailed instructions in the service manual available via the Signify Service tag apps (Android and iOS).
Disconnect before servicing
Luminaire has basic insulation between Low Voltage supply and control conductors.
The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.
This product contains a light source of energy efficiency class: see table or label.
Zhaga-D4i and SR certified compatibility – For Zhaga-D4i/SR-Certified
based luminaires only Zhaga-D4i/SR-Certified components/sensors are to be used
(see also: https://www.zhagastandard.org/products
https://www.lighting.philips.co.uk/oem-emea/products/driving-connected-
lighting). The functional compatibility of two SR-certified and/or Zhaga-D4i
controllers/sensors to be used in combination, as well as the override
possibility of any line-switch function used in an SR-based/Zhaga-D4i
luminaire, is to be released by the master controller/sensor supplier. If
using a NEMA 7-pin socket on an SR-based luminaire, a full system verification
is required. Not following this advice can/will cause risk of damage and non-
compliance for which Signify cannot take any responsibility.
© 2022 Signify Holding
All rights reserved. Reproduction in whole or in part is prohibited without
the prior written consent of the copyright owner. The information presented in
this document does not form part of any quotation or contract, is believed to
be accurate and reliable and may be changed without notice. No liability will
be accepted by the publisher for any consequence of its use. Publication
thereof does not convey nor imply any license under patent- or other
industrial or intellectual property rights.
Signify Holding.
The Netherlands
Read User Manual Online (PDF format)