Lumen package| Lamp color| Optics| Driver| Power [W]

+/-1 0%

| Efficiency class| Lumen package| Lamp color| Op�cs| Driver| Power [W]

+/-1 0%

| Efficiency class
---|---|---|---|---|---|---|---|---|---|---|---
12/15/19/25/31/34/43| 930

940

| OC| POE| 9/10,4/13/17,1 21,5/24/30,8| D| 15/19/25/30/34/40/50| 930| OC| SRD| 11,6/14,2/18,8/23 25,5/30/31,5| E
17/40| 940| OC| POE| 12,2/28| 15| 940| OC| SRD| 11,2
12/17/19/25/30/34/40/43/50/68| 940| OC| PSD| 9,1/12,2/14/18,2/22 24,5/28,5/30,5/36/48,5| 19/38| 940| NOC| SRD| 17,2/33,5
31/38/62/86| 930

940

| OC| PSD| 22,5/27,5/45/61,5| 30/38/50/62| 940| NOC| PSD| 26,5/34/45/56
19/25/30/34/40/50| 940| OC| SRD| 13,4/17,6/22/24/28/35,5| 12/17/19/25/30/34/40/43/50/68| 930| OC| PSD| 9,6/12,8/14,8/19,2/23 26/30,5/32/38/51
31/38/43/62/68/86| 930

940

| OC| SRD| 22/27,5/30,8/43,8/48,8/62| 7/15| 930

940

| OC| PSD| 6,2/11,7
86| 940| ASSY| PSD| 63| 19| 930

940

| NOC| POE| 16,8
12|

930

940

| NOC| POE| 11,9| F| 17/40| 930| OC| POE| 13/30
7/12/15/19/25/31| NOC| PSD| 7,4/12,1/14,7/18,2/24,3/29,8| 15/25/31| 940| NOC| POE| 13,2/22,5/28
15/25/30/31/50/62| NOC| SRD| 14,1/23,8/28,3/29,3/47,5/59| 34/40/43/50/68/80| 930

940

| ASSY| PSD| 26,8/32/33,5 39,5/53/62,5
19/38| 930| NOC| SRD| 18/35,5| 86| 930| ASSY| PSD| 67
30/38/50/62| NOC| PSD| 28/35,5/48/59| 15/19/25/30/31/34/38/40/43/50/62/68/86| TW9| OC| SIA/DIA| 13,2/16,2/20/26,5/24,5/27,5 32,5/33/35,5/40,8/49/55/71
15/19/25/30/31/38/50/62| TW9| NOC| SIA/DIA| 16,4/20,5/27/32,5/34/41/54/68

Recessed VPC

Recessed VPC

Recessed PCV

![Recessed

PCV](https://manuals.plus/wp-content/uploads/2023/01/PHILIPS-RC530B-TrueLine- LED-Panel-Recessed-Instruction-Manual-7.png)

Recessed Line (VPC/PCV)

Recessed Line \(VPC/PCV\)

Recessed| Geometry| A
[mm]| B
[mm]| Sensor/Blind sensor cover|
---|---|---|---|---|---
VPC| W8L120| 1197| 1130|  | 2,6
1170| •| 2,8

2,8

W8L125| 1247| 1130|
1170| •| 2,9

3,2

W8L150| 1497| 1410| •
1450|  | 3,3

Recessed

|

Geometry

| A
[mm]| B
[mm]| Sensor/Blind sensor cover|
---|---|---|---|---|---

PCV

| W8L113| 1152| 1208|  | 2,6
W8L117| 1192| 1248| •| 2,8
W8L141| 1432| 2052,2|  | 3,1
W8L145| 1472| 2092,5| •| 3,4
Recessed| Geometry| A
[mm]| B
[mm]| Sensor/Blind sensor cover|
---|---|---|---|---|---
Line

VPC/PCV

| W8L113| 1127| –|  | 2,5/2,7
W8L117| 1167| –| •| 2,7/2,9
W8L141| 1408| –|  | 3/3,2
W8L145| 1448| –| •| 3,2/3,5

583 – 442710705443
© 04/2022, Signify Holding. All rights reserved.

Optinal:

RC530Z EP SET WH
![RC530Z

EP SET WH](https://manuals.plus/wp-content/uploads/2023/01/PHILIPS-RC530B- TrueLine-LED-Panel-Recessed-Instruction-Manual-11.png)

Recessed (add safety cable if required)

![Recessed

(add safety cable if required)](https://manuals.plus/wp- content/uploads/2023/01/PHILIPS-RC530B-TrueLine-LED-Panel-Recessed- Instruction-Manual-12.png)
![Recessed

(add safety cable if required)](https://manuals.plus/wp- content/uploads/2023/01/PHILIPS-RC530B-TrueLine-LED-Panel-Recessed- Instruction-Manual-13.png)
![Recessed

(add safety cable if required)](https://manuals.plus/wp- content/uploads/2023/01/PHILIPS-RC530B-TrueLine-LED-Panel-Recessed- Instruction-Manual-14.png)

Recessed Line

Recessed Line
Recessed Line
Recessed Line

PI3, PI5 in line
Connect maximum 10 luminaires in a power cable.
The 11th luminaire should get the power from a new power cable. Don’t connect it to the previous luminaire

PI3, PI5 in line

Push-in (PIP) PSD/DIA
PI-5
Line End / Line Feature

Push-in \(PIP\) PSD/DIA

PSD/DIA
PI5-PI2
Line End / Line Feature

PSD/DIA

Push-in (PIP) SRD/SIA
PI-3
Line End / Line Feature

Push-in \(PIP\) SRD/SIA
Push-in \(PIP\) SRD/SIA

PoE
Condition Philips to specify to the customers (instruction):

to use UTP (Unshielded Twisted Pair) CAT5E or CAT6 cable.
the maximum length of the cable to be 20 meters.
Apply a minimum radius of the Ethernet cable of 4x the cable diameter.

PoE

Minimal build-in dimensions for thermal insulation [mm]

 |

Recessed

---|---
4ft| 5ft
Height| 120| 120
Width| 380| 380
Length| 1360| 1660

dimensions

Cover remover (ZZS400 OCR)

Cover remover \(ZZS400 OCR\)

Sensor upgrade procedure

  1. Push and twist screwdriver in designated slot to click out the bracket, including the sensor
    Sensor upgrade procedure

  2. Once unlocked, take out sensor from the front
    Sensor upgrade procedure

  3. 3/a Connect the new sensor to the wires  and put it into the designated slot, click the bracket in
    Sensor upgrade procedure
    3/a If you use a blind cap instead of a sensor,  insert the cable into the blind cap
    Sensor upgrade procedure

Inrush current

Inrush current

Nr of drivers 1 1 1 2 3
Electrical characteristics PSD SRO DIA/SIA DIA/SIA DIA/SIA
I   l max[A] 25 21 29,6 59,2 45,6
Tref [µs] 200 300 350 350 300
MCB Luminaire PSD SRO DIA/SIA DIA/SIA DIA/SIA
I       B-4A 5 5 4 1 2
B-6A 8 8 6 2 4
B-10A 12 13 10 4 6
8-13A 16 17 13 5 8

I

8-16A

| 20| 21| 16| 6| 10
B-20A| 25| 26| 20| 8| 12     ·
I            8-25A| 31| 32| 25| 10| 15
B-32A| 40| 42| 32| 12| 20
8-40A| so| 52| 40| 15| 24
C-4A| 8| 9| 6| 2| 4
C-6A| 12| 13| 10| 4| 6
C-10A| 21| 22| 16| 6| 10
C-13A| 27| 28| 21| 8| 13
C-16A| 34| 35| 27| 10| 17
C-20A| 41| 43| 33| 13| 20
C-25A| 52| 54| 41| 16| 25
I      C-32A| 68| 71| 54| 21| 33
C-40A| 83| 87| 66| 26| 41

Given the choices made in this unique lighting concept, there are a few instructions regarding the maintenance.

  • Prevent water from entering on or in the luminaire at installation and during use of the luminaire
  • During installation or maintaining the luminaire please use gloves to avoid spots on the cover.
  • Do not clean with a dry cloth as it will cause the product to attract dust. Dirty spots can be removed: Only dust: use a damped cloth (no dripping water), preferably anti-static. Fingerprints etc: use a damped cloth (no dripping water) with a cleaner appropriate for polycarbonate/PMMA plastics.
  • Do not touch electronic components as they are ESD sensitive.
  • Do not stare into LED beam.
  • Luminaire should not be used for illumination during building activities due to dust accumulation inside the luminaire.

The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced

Symbols

QR Code

To get an overview of all spare parts for a luminaire, please refer to detailed instructions in the service manual available via the Signify Service tag apps (Android and iOS).

Disconnect before servicing

Luminaire has basic insulation between Low Voltage supply and control conductors.

The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.

This product contains a light source of energy efficiency class: see table or label.

Zhaga-D4i and SR certified compatibility – For Zhaga-D4i/SR-Certified based luminaires only Zhaga-D4i/SR-Certified components/sensors are to be used (see also: https://www.zhagastandard.org/products
https://www.lighting.philips.co.uk/oem-emea/products/driving-connected- lighting). The functional compatibility of two SR-certified and/or Zhaga-D4i controllers/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based/Zhaga-D4i luminaire, is to be released by the master controller/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non- compliance for which Signify cannot take any responsibility.

© 2022 Signify Holding
All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights.
Signify Holding.
The Netherlands

Philips

PHILIPS  Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals