GIRA 2361 00 Light Signal Instruction Manual

June 9, 2024
GIRA

GIRA 2361 00 Light Signal

Safety instructions

Electrical devices may only be mounted and connected by electrically skilled persons.

  • Serious injuries, fire or property damage possible. Please read and follow manual fully.
  • Danger of electric shock. Always disconnect device before working on it. At the same time, take into account all circuit breakers that supply dangerous voltage to the device.
  • Fire hazard. Do not operate the LED luminaires on a dimmer. The LED luminaires cannot be dimmed.
  • Do not connect LED luminaires to an electronic switch insert. Damage to LED lumin-aires and switch insert may result.
  • The device is not suitable for use in safety-related applications or as an emergency light.
  • This manual is an integral part of the product, and must remain with the end cus-tomer.

Device components

  1. Flush-mounted insert, luminaire
  2. Cover frame, not included in the scope of delivery
  3. Labelling film, optional
  4. Light-scattering film
  5. Lamp cover

Intended use

  • Luminaire for orientation or signalling
  • Switchable using external switch
  • Mounting in appliance box with dimensions according to DIN 49073

Product characteristics

  • Can be used in switch combinations or individually
  • Makes it easier to find switches or to orient oneself in dark rooms
  • Individually labelled film can be inserted
  • Brightness can be changed using internal potentiometer LED production tolerances may result in visible differences in brightness and colour.

Operation

The luminaire is switched on or off with a switch or switching contact.

Operate switch. Luminaire switches on or off.

Information for electrically skilled persons

DANGER!
Electric shock when live parts are touched.
Electric shocks can be fatal.
Before working on the device, disconnect all corresponding circuit breakers from the supply voltage, secure against being switched on again and check that there is no voltage!

Connect and mount the LED orientation light

GIRA 2361 00 Light Signal-fig3

  • (1) Flush-mounted insert, luminaire
  • (6) Switch
  • Connect flush-mounted insert (1) as shown in the connection example (see figure 2).
  • Mount the flush-mounted insert (1) in the appliance box. The terminals must be at the bottom.
  • Complete the luminaire (see figure 1).
  • Switch on mains voltage.

Changing the brightness of the LED orientation light
When delivered, the luminaire (1) is at maximum brightness.

DANGER!
Mortal danger of electric shock.
The following work must be carried out under mains voltage and therefore may only be carried out by an electrician!
Only use insulated tools for the work! Cover up live parts in the working environment.

  • Switch off mains voltage.
  • Remove lamp cover.
  • Remove flush-mounted insert (1) from the appliance box. When doing this, en-sure insulation of the cables in accordance with regulations.
  • Switch on mains voltage.
  • Switch on luminaire with switch (6).
  • Adjust brightness by turning the adjuster (7) (see figure 3).
  • Switch off mains voltage.
  • Mount the flush-mounted insert (1) in the appliance box. The terminals must be at the bottom.
  • Fit lamp cover again.
  • Switch on mains voltage.

Technical data

  • Rated voltage AC 230 V ~
  • Mains frequency 50 Hz
  • Ambient temperature -15 … +40 °C
  • Power consumption approx. 8.5 VA
  • Power factor 0.2
  • Brightness range 3 … 100%
  • Number of LEDs 4
  • Colour temperature
  • Order no. 2361 00 approx. 5000 K
  • Order no. 2364 00 approx. 2700 K
  • Connection
    Single stranded 1.5 mm²

Warranty

The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with an error de-scription to your responsible salesperson (specialist trade/installation company/elec-trical specialist trade). They will forward the devices to the Gira Service Center.

Gira
Giersiepen GmbH & Co. KG
Elektro-Installations-
Systeme
Industriegebiet Mermbach
Dahlienstraße
42477 Radevormwald
Postfach 12 20
42461 Radevormwald
Deutschland
Tel +49(0)21 95 – 602-0
Fax +49(0)21 95 – 602-191
www.gira.de
info@gira.de

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals