GIRA 5301 00 eNet Server Instruction Manual

October 26, 2023
GIRA

5301 00 eNet Server
Instruction Manual

5301 00 eNet Server

GIRA 5301 00 eNet ServerSafety instructions

Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire, or property damage are possible. Please read and follow the manual fully.
Fire hazard! Operation exclusively with the power supplies listed under accessories The radio communication takes place via a non-exclusively available transmission path and is therefore not suitable for safety-related applications, such as emergency stops and emergency calls.
This manual is an integral part of the product and must remain with the end customer.

Device components

GIRA 5301 00 eNet Server - fig

  1. Slide for retaining the antenna cable
  2. Buttons for manual operation and restart
  3. LEDs
  4. Voltage supply connection
  5. Data cable connection
  6. Socket for external eNet antenna
  7. RJ45 socket for Ethernet connection
  8. Socket for external WLAN antenna

Function

Intended use

  • Commissioning, diagnosis, and maintenance of an eNet installation via PC, tablet, and laptop
  • Operation of an eNet installation via smartphone
  • Radio receiver for eNet RMD modules
  • Operation only with approved voltage supply (see accessories)
  • Mounting on DIN rail according to EN 60715 in distribution boxes with voltage supply RMD

Product characteristics

  • Internal eNet radio and WLAN antenna
  • External eNet radio and WLAN antennas for extending the radio ranges can additionally, be connected
  • LEDs for signaling
  • Buttons for construction site mode and restart of the eNet server
  • The electrical separation between the connections of the external antennas and the Ethernet connection
  • Fully-encrypted radio transmission (AES-CCM) from eNet Server software version

2.0 Signalling
The table below provides an overview of the signalling via LEDs of the eNet server.

Labelling, Colour of the LED Function
POWER, green Flashes: eNet-Server starts Illuminated: eNet server ready for

operation
, green| eNet radio transmission active
SCAN, green| Scan operating mode active
LAN, green| Ethernet connection active
WLAN, green| WLAN connection active

Operation

Operation on the deviceGIRA 5301 00 eNet Server - fig
1

(9)The button  I : All On
(10)Button O : All Off
(11)Button : All Up
(12)Button All Down
(13)Button RESTART
Switching all switches and dimmers

  • Press the I button to switch it on.
  • Press the O button to switch it off.

Moving all blinds/shutters

  • Press the button to raise the blinds/shutters.
  • Press button to lower the blinds/shutters.

Performing a restart
The eNet server can be restarted without voltage interruption via the RESTART button.

  • Press the RESTART button (13) for longer than 10 seconds. A restart of the eNet server is performed. The POWER LED flashes during the restart and illuminates when the eNet server is ready for operation. Resetting network configuration
  • Press the RESTART button (13) for longer than 4 seconds. The POWER, and SCAN LEDs flash.
  • To reset the network configuration to LAN with the fixed IP address (192.168.0.22), press button within 10 seconds.
  • To reset the network configuration to LAN with DHCP-Modus, press button within 10 seconds.
    The network configuration is reset and WLAN is deactivated.

Resetting users and passwords to factory setting

  • Press the RESTART button (13) for longer than 4 seconds. The POWER, and SCAN LEDs flash.
  • Within 10 seconds press the I button for 4 seconds. Users and passwords are reset to the factory settings. A restart of the eNet server is performed. The POWER LED flashes during the restart and illuminates when the eNet server is ready for operation.

For the first log-on, enter “admin” both as the username and password. For security reasons, change the password after this.
Delete project

  • Press the RESTART button (13) for longer than 4 seconds. The POWER, and SCAN LEDs flash.
  • Within 10 seconds press the O button for 4 seconds. The project is deleted. A restart of the eNet server is performed. The POWER LED flashes during the restart and illuminates when the eNet server is ready for operation.

Information for electrically skilled persons

5.1 Mounting and electrical connection
DANGER!
The electrical shock on contact with live parts in the installation environment. Electric shocks can be fatal.
Before working on the device, disconnect the power supply and cover up live parts in the working environment.
Connecting external antennas
An external WLAN antenna can be connected to improve the radio range of the WLAN connection. An eNet antenna can be connected to improve the radio range between the eNet server and installation devices.

  • Unlock slide (1) by pulling the end of the bow forwards. Pull out the slide.
  • Place the antenna outside of the distribution board and insert the antenna cable into the distribution board.

The eNet antenna must be mounted on a metallic surface.
The antenna cables carry SELV potential and are only singly insulated. Ensure safe isolation from other voltages, e.g. through insulation.

  • Insert the antenna connector into the socket (6) for the eNet antenna or socket (8) for the WiFi antenna.
  • Re-insert slide (1) until it engages noticeably.

The slide fixes the antenna cable in place and ensures that the maximum installation height in the distribution board is maintained.
Mounting the device
Observe the temperature range. Ensure adequate cooling.

  • Mount the device on the DIN rail with the terminals facing downwards. facing downwards. Connecting the device

GIRA 5301 00 eNet Server - fig 2

Use a suitable bus line, e.g. J-Y(St)Y 2x2x0.8.

  • Connect the device according to the connection diagram (see figure 3).

Unfavourable installation conditions make radio reception more difficult. In the case of metallic sub-divisions etc., connect the external antenna and position it on a metallic surface outside of the distribution board.
Do not connect the eNet server to an RMD radio receiver.
Connection assignment

Labeling / Colour Connection
DC–, GY / dark grey Voltage supply, –
DC+, RD / red Voltage supply, +
BUS–, WH / white Data cable, –
BUS+, YE / yellow Data cable, +

Connect the voltage supplyGIRA 5301 00 eNet Server - fig
3

  • Connect the voltage supply to connection (4) of the eNet server.
  • Switch on the voltage.
    The eNet server is started.

5.2 Commissioning
Connecting computer with eNet server
A wired network connection (LAN) via a router is required for the first commissioning of the eNet Server. Addressing takes place automatically via DHCP. In the as-delivered state, the eNet Server is appropriately preconfigured.
Supported web browsers: Google Chrome, Firefox, EDGE
Precondition: The eNet Server is installed, and the voltage supply and any external antennas are connected.
Connection via IP address of the eNet Server
Precondition: The eNet SMART HOME app is installed on a smartphone. The smartphone is connected to a WiFi router.
The IP address of the eNet server can be found on the Home page and in the System menu of the app.

  • Set up the network connection between the eNet Server and the computer via the Wifi router.
  • Start a web browser.
  • Enter the IP address of the eNet Server in the address line of the web browser.
    The log-in window of the commissioning interface is opened in the web browser.

Connection via the domain name of the eNet Server

  • Set up the network connection between the eNet Server and the computer via a WiFi router.
  • Start web browser.
  • Enter the XenServer in the address line of the web browser.

With some routers, the hostname of the router must also be entered, e.g. XenServer.fritz.box. The log-in window of the commissioning interface is opened in the web browser.
Log into the commissioning interface

  • Enter your username and password.

For the first log-on, enter “admin” both as the username and password. For security reasons, change the password after this.

  • Select Anmelden.

For trouble-free data transmission, a wired connection via LAN is recommended.

Legal Notice
This product incorporates open-source software components covered by the terms of third-party copyright notices and/or license agreements. The technical documentation of the eNet server contains detailed information on this.

Technical data

Rated voltage DC 12 V SELV
Current consumption 400 mA
Power consumption
Operation max. 6 W
Standby max. 2 W
Ambient temperature -5 … +45 °C
Storage/transport temperature -20 … +70 °C
Relative humidity 20 … 70 % (no moisture condensation)
Protection class III
Installation width 108 mm / 6 HP
Connections
Supply device connection terminal
LAN RJ45-socket 8/4-pin
WLAN antenna, external SMB socket
Bus line
Cable length max. 3 m
RMD channels
Number max. 32
IP communication
LAN Ethernet 10/100 MBit
IP connections max. 8
WLAN (IEEE 802.11g)
Radiofrequency 2.400 … 2.483 GHz
Transmission capacity max. 100 mW

eNet communication
Radiofrequency| 868.0 … 868.6 MHz
Transmission capacity| max. 20 mW
Transmitting range in free field| typ. 100 m
Receiver category| 2

Accessories

Power supply 12 V DC / 2 A DRA Order no. 5319 00
Additional radio antenna Order no. 5307 00
Additional WLAN antenna Order no. 5308 00

Conformity

Hereby Gira Giersiepen GmbH & Co. KG declares that the radio system type Order no. 5301 00
corresponds to the directive 2014/53/EU. You can find the full article number on the device. The complete text of the EU Declaration of Conformity is available under the
Internet address: www.gira.de/konformitaet

Warranty

The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center.

Additional information

You can find a Quick Start Guide as an introduction to working with the eNet Server, product documentation for working with the eNet SMART HOME connect and additional information on the eNet system at www.gira.de
.

Gira
Giersiepen GmbH & Co. KG
Elektro-InstallationsSysteme
Industriegebiet Mermbach
Dahlienstraße
42477 Radevormwald
Postfach 12 20
42461 Radevormwald
Deutschland
Tel +49(0)21 95 – 602-0
Fax +49(0)21 95 – 602-191
www.gira.de
info@gira.de
32580562
10869904
29.09.2022

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals