BRISTAN PM2 SHCDIV BLK Thermostatic Recessed Dual Control Valve User Guide

June 9, 2024
BRISTAN

BRISTAN PM2 SHCDIV BLK Thermostatic Recessed Dual Control Valve

BRISTAN PM2 SHCDIV BLK Thermostatic Recessed Dual Control
Valve

Specifications

Dynamic Water Pressure
  • Min : 0.2 bar
    Dynamic Water Pressure 

  • Max : 5.0 bar
    Dynamic Water Pressure 

  • Maximum Static Pressure: 10.0 bar

Inlet Water Temperature
  • **Cold Water Supply

Min: 5°C Max: 25°C
**

  • **Hot Water Supply

** 65°C Recommended

IMPORTANT
The inlet hot water must be at least 10°C above the required blend temperature.

Inlet Dimensions

Inlet Dimensions

Inlet Connections

Inlet Connections

Tools You’ll Need

Socket Spanner
Tools You’ll Need

|

Flat head
Screwdriver

|

Drill

|

Adjustable Spanner

---|---|---|---

Pipe Cutter

|

Silicon Sealant

|

Hexagonal Keys

|

Pipe & Wire Detector

Prior to Installation

All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions

This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws. For full Installation Requirements & Notes (IRN) please visit wras.co.uk/directory

Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance. Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc.  Full access must be made available for future maintenance/ servicing purposes.

Before drilling into walls, check that there are no hidden electrical wires, cables or water supply pipes. This can be checked with the aid of an electronic detector.

If power tools are used do not forget to:
– Wear eye protection
– Unplug equipment after use

This product must not be modified in any way as this will invalidate the guarantee.
If in doubt, contact a registered plumber, your Local Water Authority or the Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791

Cavity Dimensions (mm)

Minimum Fitting Depth : 50mm
Maximum Fitting Depth : 75mm
Concealing Plate Adjustment Range : 25mm

Cavity Dimensions \(mm\)

Pack Contents

Pack Contents

Valve Configuration

  1. Remove the inlet elbows and filters. Remove the plastic inserts from the valve inlets and insert the flow regulators. Replace the elbows, ensuring the filters are fitted.
    Valve Configuration

  2. Screw the shrouds onto the valve.
    Valve Configuration

Installation

  1. Install suitable batons (if required)  into the cavity. Take the finished wall surface into consideration when fitting the valve into the cavity. Mark the position of the valve; drill and plug holes to suit.
    Installation

  2. Secure the valve using the screws supplied (solid walls only) or a suitable alternative.
    Installation

  3. Connect the inlet pipes ensuring the olives are fitted.
    Installation

  4. Plumb your chosen outlets into the valve.
    Turn on the water supply and check the valve for any leaks
    Installation

  5. Draw around the concealing plate as a template, measuring in by 10mm to give clearance. Finish the wall surface. Using a silicon sealant, push on the concealing plate and hold firmly until set.
    Installation

  6. Fit the handles.
    Installation

Temperature Adjustment

  1. Turn the handle to the maximum temperature setting, then remove it.
    Temperature Adjustment

  2. Turn the spindle to increase or decrease the temperature. Check the temperature and adjust until you achieve the desired result.
    Temperature Adjustment

  3. Fit the temperature handle back in the maximum hot position.
    Temperature Adjustment

General Cleaning

Bristan products are made from premium materials, with hand polished, PVD, EPD or electroplated finishes.
Your shower should be regularly cleaned with warm water, a mild pH-neutral liquid soap, and polished with a soft cloth. Any residues from soap, toothpaste, shampoos and shower gels can cause blemishes if not rinsed off straight after use.
Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar.

Operation

Operation

Maintenance – Cartridge Cleaning

Maintenance - Cartridge Cleaning

Unscrew the shrouds. Remove the cartridges and piston.

Maintenance - Cartridge Cleaning

Remove any O-rings and soak all components in de-scaler and wash off in clean water. Examine all seals and replace if needed. Use WRAS approved silicon based grease on all seals.

Maintenance - Cartridge Cleaning

Reverse the installation steps, ensuring the temperature stop is aligned correctly

Maintenance - Cartridge Cleaning

Follow the Temperature Adjustment steps if required.

Maintenance - Cartridge Cleaning

Troubleshooting

Symptom

|

Cause

|

Remedy

---|---|---
No flow or low flow rate| Partially closed isolation valve.| Open isolation valve.
Instantaneous water heater cycles on and off as flow rate or pressure is too low.| Increase water flow rate or pressure through system.
Head of water is below the minimum distance required.| Refer to the specification for the minimum distance required.
Are the water supply pressures balanced?| If pressures are unbalanced, a pressure reducing valve should be used for optimum performance.
Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous boiler temperature changes.| Do not use other water outlets when using the shower.
Airlock or partial blockage in the supply pipework.| Flush through pipework and filters to ensure removal of debris and any airlocks.
Hot/Cold water supply has failed| Check the hot and cold feeds. The shower will not work if either fails.
Maximum Water Temperature too Hot/Cold| Maximum Water Temperature needs adjusting.| Refer to the Temperature Setting section to set your desired maximum temperature.
Outlet Water Temperature too Hot/Cold| Filter/pipe blockage| Flush through pipework and filters to ensure removal of debris and any airlocks.
Installation conditions outside operating parameters.| Refer to the specification for the minimum distance required.
Hot water temperature is less than 10°C above the required blend temperature| Adjust hot water temperature or wait for water to reheat if a stored water system is used.
Instantaneous water not igniting because the water flow rate is too low.| Increase water flow rate through the system. Refer to the Maintenance section to clean/check the cartridge and filters for any damage. Contact your boiler manufacturer.
Instantaneous water not igniting because the water pressure is too low.| Refer to the specification for system requirements.

Increase water pressure through the system.

Contact your boiler manufacturer.

Only hot/ cold water from Shower Valve

| Inlet water supplies are reversed.| Check the water inlet connections are the correct way around: Hot on the left, Cold on the right when viewed from the front. Rework pipework as necessary.
Filter/pipe blockage| Flush through pipework and filters to ensure removal of debris and any airlocks.
Water dripping from shower| This is normal for a short time after using the shower.| This is caused by residual water tension, the build up of water in the shower.
If water continues to drip, possibly due to the cartridge| Remove cartridge and clean, refer to ‘Maintenance’ section before starting any maintenance.
Shower does not turn on| Closed isolation valve.| Open isolation valve.
Mains water supply turned off.| Turn on mains water supply.

Our Guarantee

At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product. Alternatively visit www.bristan.com/register.

QR Code

For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice.

For full guarantee terms and conditions visit www.bristan.com/service- centre/guarantees.

Bristan Group Ltd.

UK: Bristan Group, B78 1SG.
EU: Masco Europe S.à.r.l., 14 Rue Strachen 6933 Mensdorf, Luxembourg.

Customer Service: +44330 026 6273
Web: www.bristan.com
Email: enquire@bristan.com

BRISTAN  Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>