COYOTE CIC28 Series CIC28LP 28-Inch Built-In Grill Installation Guide

June 4, 2024
COYOTE

COYOTE CIC28 Series CIC28LP 28-Inch Built-In Grill Installation Guide
COYOTE CIC28 Series CIC28LP 28-Inch Built-In Grill

DIMENSIONAL RENDERINGS

DIMENSIONAL RENDERINGS

Overall Product Dimensions

Model No.| Height| Width| Depth
C1C28| 23″| 28″| 25 1/2″
CJAKTCC2| 11″| 30 1/8″| 23″
Cutout Dimensions for Island

Model No.| Height| Width| Depth
C1C28| 10 1/4″| 25″| 20 1/2″
CJAKTCC2| 11″| 28 1/4″| 22 1/8″

When using a Coyote insulated jacket, you will want to build your island to the jackets Cutout and Overall Dimensions listed above. Once the jacket is installed, the grill will rest on/inside the insulated jacket

Model No.| Gas Supply| BTU’s| Regulator| WC Pressure| Max PSI| Electrical Requirements
---|---|---|---|---|---|---
C1C28LP| Propane| 40,000| 20 lb Tank Regulator| 11″| .5 PSI| Qty 1 – 120 VAC 60 Hz Grounded Plug
C1C28NG| _ Natural Gas| 40,000| 1/2″ Female Pipe| 4″| .5 PSI| _ Qty 1 – 120 VAC 60 Hz Grounded Plug

Important Note to Installer: This file is not intended to replace your Owners’ Manual which contains specific safety requirements and consumer guidelines. Please refer to your Owners’ Manual prior to installing or operating your built-in grill.

NON-COMBUSTIBLE CONSTRUCTION

Insulated Jacket Required – Model # CJAKTCC2

NON-COMBUSTIBLE CONSTRUCTION

  • Combustible material can not be within 24″ of the grills frame
  • This applies to all directions – horizontal & vertical
  • Shaded area above on “TOP VIEW” illustrates the 24″ minimum requirement (not to scale for rendering purposes)
  • The grill is designed to hang from the counter top with no support underneath
  • Minimum rear clearance for the hood to open is 2″
  • If you have a wall/partition behind the grill, the minimum rear clearance to that wall should be at least 7″ to allow for ventilation of the exhaust

COMBUSTIBLE CONSTRUCTION

Insulated Jacket NOT Required

COMBUSTIBLE CONSTRUCTION

  • If using combustible material within 24″ of the grill frame, you MUST use the corresponding Coyote Insulated Jacket
  • Using a insulated jacket, does not waive any other standard installation procedure (ventilation, connections, etc)
  • The jacket is designed to hang from the counter top with no support underneath
  • Minimum clearance for hood to open is 2″
  • If you have a wall/partition behind the grill, the minimum rear clearance to that wall should be at least 7″ to allow for ventilation of the exhaust

Ventilation Requirements

  • Regardless if you are using a combustible or non-combustible building material, you must include at least two vents within the island.
  • These vents must be at least 20 sq. in. each and allow fresh air to move from the grill cabinet to the exterior environment.
  • For a propane setup, the vents should be installed lower as propane is heavier than air.
  • For a natural gas setup, the vents should be located higher in the island, as natural gas is lighter than air.
  • Do not locate the two vents on the same wall of the island. Cross ventilation is key to allow any excess heat or trapped gas to dissipate.

Important Note to installer This file is not intended to replace your Owners’ Manual which contains specific safety requirements and consumer guidelines. Please refer to your Owners’ Manual prior to installing or operating your built-in grill.

Scan OR Code for brief safety and installation video.
www.coyoteoutdoor.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

COYOTE User Manuals

Related Manuals