FFSGS6244-36 36 Inch Galiano Gas Range

Minimum to cabinets on either sides of the range
Maximum depth for cabinets above countertop

Opening width W
30″ Model 30″ (762mm)
36″ Model 36″ (914mm)
48″ Model 48″ (1219mm)
60″ Model 60″ (1520mm)

Exhaust Hood Installation

The bottom of the hood should be 30″ min. to 36″ above the countertop. This would typically result in the bottom of the hood being 66″ to 72″ above the floor. These dimensions provide safe and efficient operation of the hood. After Installation:

  1. Check ignition of cooktop burners.
  2. Check the air shutter adjustment – sharp blue flame, with no yellow tipping or lifting flames.
  3. Check ignition of oven burner.
  4. Visually check tubular burner (oven burner) re-ignition to be sure both rows of burner ports are relighting each time.
  5. Check for gas leaks at all gas connections (using a gas detector, never use a flame).
  6. Check oven bake and convection bake function.

Gas Conversion Operation
This cooking range can be used with LP gas and NG gas. It is shipped from the factory adjusted for use with NG(Nature Gas). Injector for LP gas are included. Follow the instruction shown below for gas conversion.
WARNING
Gas conversion shall be conducted by a factory- trained professional. Call the customer service hotline to identify a factory-trained professional near your home.