AFX LIGHT 16-2046 CLUB-KALEDO Package User Manual

June 9, 2024
AFX LIGHT

AFX LIGHT 16-2046 CLUB-KALEIDO Package

AFX-LIGHT-16-2046-CLUB-KALEDO-Package-User-Manual-
product

FEATURES

  •  7 x 10W RGBW LED
  •  LED strip generating a kaleidoscope effect
  •  Strobe effect
  •  LED display
  •  12/17 DMX channels
  •  Auto, DMX, master-slave, music or remote-controlled operation
  •  Powercon in-/outputs
  •  Overheat protection
  •  Dual bracket for floor or truss mounting
  •  IR remote control
  •  Signal lead, power lead, and safety rope are included

EXPLANATION OF SYMBOLS

The triangle containing a lightning symbol is used to indicate whenever your health is at risk (due to electrocution, for example).
An exclamation mark in a triangle indicates particular risks in handling or operating the appliance. The unit complies with UK standards
For indoor use only
Protection class I. Requires an earth connection
The minimum distance between the appliance and other objects Don’t stare into the light beam

CAUTION
DO NOT OPEN THE HOUSING SHOCK HAZARD

SAFETY RECOMMENDATIONS

  •  Please read these instructions carefully, they include important information about the installa-tion, usage and maintenance of this product.
  •  Please keep this User Guide for future reference.
  •  Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the bottom of the fixture.
  •  The appliance is part of class I and must be exclusively connected to an earthed mains outlet.
  •  This product is intended for indoor use only!
  •  To prevent risk of fire or shock, do not expose the fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating.
  •  The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.
  •  The minimum distance luminaire from that part of the luminaire or lamp to the lighted object is 0.5m. 0.5m
  •  The max. ambient temperature (Ta) is 40°C. Don’t operate the fixture at higher temperatures.
  •  The surface temperature of the unit may reach up to 85°C. DO NOT TOUCH the housing bare hand during its operation. Turn off the power and allow about 20 minutes for the unit to cool down before replacing or servicing it.
  •  DO NOT OPEN the unit within 5 minutes after switching off.
  •  In the event of a serious operating problem, stop using the unit immediately.
  • Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type of spare parts.
  •  Make sure the power cord is never crimped or damaged.
  •  Avoid direct eye exposure to the light source while it is on as sensitive persons may suffer an epileptic shock (especially meant for epileptics)!.
  •  The product is for decorative purposes only and not suitable as a household room illumination.
  •  If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similarly qualified person in order to avoid a hazard.
  •  The lenses, housing or ultraviolet filter must be replaced if they are visibly damaged.
  •  Please note that the lamp of this device cannot be replaced. If the lamp is faulty, the unit must be discarded

DISCONNECT DEVICE
Please note that the unit DOES NOT have an ON/OFF switch. Please unplug the unit to remove completely the power from the internal circuits before cleaning or servicing. Therefore, the disconnect device shall remain readily accessible.

INSTALLATION

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety rope. Never stand directly below the device when mounting, removing or servicing the fixture.

POWER SUPPLY AND SIGNAL CABLE CONNECTION

Mains Power connection
The exclusive plug should be used between the connection of unit and the power. Please ensure that the rated voltage and frequency are in accordance with the power supply. The required input voltage and frequency are: 90-240V~ 50/60Hz We suggest that every light has an independent switch so that you can turn on or turn off the light randomly.
Note: the ground wire (yellow/green double-color wire) must be safely connected, the electrical installation must be in accordance with the related standards

CAUTION : When installing the device, make sure there is no highly inflammable material within a distance of min.5m!

Connection of Signal Cable
You can use the 3-pin XLR cable to connect the output socket of the master and the input socket of the slave light. Connect the DIGITAL OUT socket of the master and the IN socket of the slave light, then, connect the OUT socket to the IN socket of the next light. Ordinal to connect all the lights as below:

The connection between the output of master and input of product, it’s available to use the 3 pins XLR cable which provided by the manufacturer. Signal cable from the DMX output of the controller to the input of the first master light, and connect to the DMX input of second slave light from the DMX output of the first master light, analogously, till connected all the slave lights, and insert the last connector to the output of the final light. (Notice: the diameter of core of every cable should be 0.5mm at least, double core shelter cable should be used).The signal connecting must use the attached 3 pins XLR cable. Notice, all the internal lead wire of the 3 pins XLR cable should not touch to each other or connect to the connector. A DMX signal terminator is recommended on the last unit of the chain. DMX terminator is a XLR connector with a 120Ω resistor between the pin 2 and pin 3 of the XLR connector

CONTROL PANEL
Use Menu button to choose a function among MODE, SET, DMX, REST, TEST and TEMP. Press Enter button to enter in the menu of the selected function Use Up and Down button to select the parameters then press Enter button to set the selected parameter
Check the following function table :

MENU DESCRIPTION

MODE

|

ADDR

| VALU| A001~A XXX (AXXX)| DMX address setting
SLAV|  |  | Stand-alone mode (Slave mode)

AUTO

|

IP1-8

| ALON /(AU-A)|

SP_1~SP_5 (Speed)

| Internal programme (alone) with speed control
MAST /AU-M)| Auto-run (Master) with speed control

SOUN

|

IP1-7

| ALON (SO-A)| Sound control (alone)
MAST/(SO-M)| Sound control (Master)

SET

| MIC| M-XX|  | Mic sensitivity setting
LOAD| ON/OFF|  | Reload data
VER| V-x.x|  | Software version

CALI

| Code (password: 088)| Input password
CH03-CH06| Calibration

DMX

| MOD1|  |  | 17CH
MOD2|  |  | 12CH
REST| ON/OFF|  |  | Reset to factory default

MANU

| rXXX| C000-255|  | Manual control red LED
gXXX| C000-255|  | Manual control green LED
bXXX| C000-255|  | Manual control blue LED
MENU| DESCRIPTION
---|---

MANU

| UXXX| C000-255|  | Manual control white LED
rXXX| C000-255|  | Manual control red pixel LED
gXXX| C000-255|  | Manual control green pixel LED
bXXX| C000-255|  | Manual control blue pixel LED
TEMP| TXXX|  |  | Current temperature

DMX channel chart: please refer to LAST page

IR REMOTE CONTROLLER
Please operate the remote control within a distance of 6m and 30° between the remote and the appliance. Aim the remote at the sensor. Remove all obstacles between the remote and the sensor. The remote control might not work properly if the sensor is exposed to strong sunshine.
If the remote control doesn’t work properly, please check the batteries.

INSTALLING THE BATTERIES IN THE REMOTE CONTROL

  •  Place the remote face down on a flat surface.
  •  Push the compartment cover into the direction of the arrow.
  •  Slide the battery compartment open.
  •  Remove the old battery and install the new one (CR2025) with the plus (+) symbol facing up.
  •  Gently slide the battery compartment closed. It locks automatically.

RECOMMENDATIONS FOR BATTERIES
This symbol indicates that used batteries should not be disposed of with household waste but deposed correctly in accordance with your local regulations..
Batteries shall not be exposed to excessive heat such as sunshine, fire or the like. When the internal batteries are not to be used, remove them to avoid damage caused by battery leakage or corrosion.

ATTENTION: Danger of explosion if the battery is incorrectly placed. Only replace by the same or equivalent type.

WARNING: Do not swallow the battery. The danger of chemical burns. Keep new and old batteries out of the reach of children. If the battery compartment doesn’t close properly, stop using the product and keep it out of the reach of children. If you are in doubt whether the batteries have been swallowed or introduced into any other part of the body, contact immediately a doctor.

REMOTE CONTROL

NOTE : PLEASE SET THE UNIT TO MODE -> ADDR, OTHERWISE
THE REMOTE CONTROL WILL NOT WORK

  1.  BRIGHTNESS & SPEED adjustment: Press brightness and speed in program mode
  2.  ON/OFF of the LEDs.
  3.  SELECT BASIC COLOR: Red, Green, Blue or White (R+G+B)
  4. COLOUR BUTTONS: For constant lighting of all LEDs in one co-lour, press the corresponding button.
  5.  SELECTING AN INTERNAL PROGRAMME:
    • Flash: Colour switch
    • Trobe: Colour strobe
    • Fade: Colour fade
    • Smooth: Colour switch and strobe

CLEANING AND USING FREQUENCY OF PRODUCT

Please make sure that the light is powered off before dismantling or maintaining it, it’s very important to keep the light clean. Frequent cleaning will ensure maximum brightness output, but also prolong the lifetime. It’s suggested to use high-quality, professional glass detergent and a soft cloth to clean the light. It’s not allowed to use alcohol or chemical solvents. The inner part of the light should be cleaned by a vacuum cleaner at least once a year. When the light doesn’t work, please check if the fuse is burnt out or not. If it is, the same fuse should be replaced, find out the faulty and restart the light. But please note the repair must be handled by a professional.

PHOTOMETRIC DIAGRAM

TECHNICAL SPECIFICATIONS

  • Input voltage………………………………………………………………………………………………………….90-240V~50/60Hz
  • Consumption……………………………………………………………………………………………………………………………….75W
  • Light sources……………………………………………………………………………………………………… 7 x 10W RGBW LEDs
  • ………………………………………………………………………………………………………………… 60 x 0.2W RGB LED strip
  • Linear color temperature…………………………………………………………………………… 2800K-8000K adjustable
  • Beam angle……………………………………………………………………………………………………………………………………20°
  • Dimensions………………………………………………………………………………………………………….265 x 117 x 213mm
  • Weight…………………………………………………………………………………………………………………………………….. 2.18kg

IMPORTANT NOTE: Electric products must not be put into household waste. Please bring them to a recycling center. Ask your local authorities or your dealer about the way to proceed.

DMX CHANNEL CHART

9

|

7

|  | Macro RUN
---|---|---|---
0..15| No function
16..31| Macro Run 1
32..47| Macro Run 2
48..63| Macro Run 3
64..79| Macro Run 4
80..95| Macro Run 5
96..111| Macro Run 6
112..127| Macro Run 7
128..143| Macro Run 8
144..159| Macro Sound 1
160..175| Macro Sound 2
176..191| Macro Sound 3
192..207| Macro Sound 4
208..223| Macro Sound 5
224..239| Macro Sound 6
240..255| Macro Sound 7
10| 8|  | Macro Speed
0..255| Macro Speed from Slow To Fast
11| 9|  | Pix_Dimmer
0..255| Pix_Dimmer 0%…100%
12|  |  | Pix_Red
0..255| 0-100% Pix_Red dimmer from dark to bright
13|  |  | Pix_Green
0..255| 0-100% Pix_Green dimmer from dark to bright
14|  |  | Pix_Blue
0..255| 0-100% Pix_Blue dimmer from dark to bright

15

|

10

|  | Pix_color
0..0| No Function
1..15| Red
16..31| Green
32..47| Blue
48..63| Red+Blue
64..79| Red+Green
80..95| Green+Blue
96..111| Red+Blue+Green
112..127| 2700K
128..143| 3200K
144..159| 3500K
160..175| 5000K
176..191| 5500K
192..207| 6000K
208..223| 6500K
224..239| 7000K
240..255| 8000K

16

|

11

|  | Pix_Macro
0..15| No Function
16..29| Pix Dynamic Scene1
30..43| Pix Dynamic Scene2
44..57| Pix Dynamic Scene3
58..71| Pix Dynamic Scene4
72..85| Pix Dynamic Scene5
86..99| Pix Dynamic Scene6
100..113| Pix Dynamic Scene7
114..127| Pix Dynamic Scene8
128..143| Pix Dynamic Scene9
142..155| Pix Dynamic Scene10
156..169| Pix Dynamic Scene11
170..183| Pix Dynamic Scene12
184..197| Pix Dynamic Scene13
198..211| Pix Dynamic Scene14

16

|

11

| 212..225| Pix Dynamic Scene15
226..239| Pix Dynamic Scene16
240..255| Pix Dynamic Scene17
17| 12|  | Pix_Macro_Speed
0..255| Slow to Fast

Assembled in PRC
Designed by LOTRONIC S.A. Av. Z. Gramme 9
B – 1480 Saintes

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals