AFX LIGHT SPOT180LED Moving Head Light User Manual

June 9, 2024
AFX LIGHT

AFX LIGHT SPOT180LED Moving Head Light

UNPACKING INSTRUCTIONS

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present and have been received in good condition. Notify the freight company immediately and retain packing material for inspection if any parts appear to be damaged from shipping or the carton itself shows signs of mishandling. Keep the carton and all packing materi-als. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.

CONTENTS OF THE CARTON

  • 1 x LED light effect
  • 1x omega clamp
  • 1x Powercon cable
  • 1x DMX lead
  • 1x User Manual

EXPLANATION OF SYMBOLS ON THE SILKSCREEN

  • The triangle containing a lightning symbol is used to indicate whenever your health is at risk (due to electrocution, for example).
  • An exclamation mark in a triangle indicates particular risks in handling or operating the appliance.
  • The unit complies with UK standards
  • For indoor use only
  • Minimum distance between the appliance and other objects Don’t stare into the light beam

Please read this manual carefully before operating this product.

SAFETY RECOMMENDATIONS

  • Please read these instructions carefully, they include important information about the installa-tion, usage and maintenance of this product.
  • Please keep this User Guide for future reference. If you sell the unit to another user, be sure that he also receives this instruction booklet.
  • Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the bottom of the fixture.
  • The appliance is part of class I and must exclusively connected to an earthed mains outlet.
  • This product is intended for indoor use only!
  • To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating.
  • The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.
  •  The minimum distance luminaire from that part of the luminaire or lamp to the lighted object is 0.5m. 0.5m
  •  The max. ambient temperature (Ta) is 40°C. Don’t operate the fixture at higher temperatures.
  • The surface temperature of the unit may reach up to 85°C. DO NOT TOUCH the housing bare-hand during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing or servicing.
  • DO NOT OPEN the unit within 5 minutes after switching off.
  •  In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type of spare parts.
  • Make sure the power cord is never crimped or damaged.
  • Never disconnect the power cord by pulling or tugging on the cord.
  • Avoid direct eye exposure to the light source while it is on as sensitive persons may suffer an epileptic shock (especially meant for epileptics)!.
  • The product is for decorative purposes only and not suitable as a household room illumination.
  • If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
  • The lenses, housing or ultraviolet filter must be replaced if they are visibly damaged.
  • The light source of this device is not replaceable. If it is defective, the entire unit must be discarded.

DISCONNECT DEVICE

Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.

FEATURES

  • 10/12/14/16 DMX channels
  • Sound active, DMX, auto, master-slave mode
  • 1 static Gobo Wheel: 8 gobos + open, rotation and shake
  • 1 rotating Gobo Wheel: 6 gobos +open, rotation and shake
  • Color Wheel: 7 colors + white, rotation with variable direction and speed
  • Prism: 3-facet Prism, bi-directionally rotatable at variable speeds
  • Automatic focus
  • High quality optics
  • 3-phase Pan/Tilt motor
  • 15° beam angle
  • High speed strobe effect with 1-25 flashes per second
  • Color LCD
  • Efficient low noise fan cooling system
  • Two ¼ turn fastening omega clamps
  • POWERCON IN/OUT
  • 3-pin XLR connectors IN/OUT
  • IP20 protection rating

INSTALLATION

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety rope. Never stand directly below the device when mounting, removing or servicing the fixture.

ORIENTATION

This fixture may be mounted either vertically on a ceiling or truss, or placed on a level surface, provided there is adequate room for ventilation.

RIGGING

The LED moving head provides a unique mounting bracket assembly that inte- grates the bottom of the base, the includ-ed ‘omega bracket’ and the safety cable rigging point in one unit (see illustration). When mounting this fixture on a truss, be sure to use an appropriate clamp with the included omega bracket using a M10 screw fitted through the center hole of the ‘omega bracket’. As an added safety measure, be sure to attach at least one properly rated safety cable to the fix-ture using one of the safety cable rigging points integrated in the base assembly.

FUSE REPLACEMENT

Disconnect the power cord before replac-ing a fuse and always replace with the same type fuse.

With a screwdriver wedge the fuse holder out of its housing. Remove the damaged fuse from its holder and replace with exactly the same type of fuse. Insert the fuse holder back in its place and reconnect power.
Warning: If after replacing the fuse you continue to blow fuses, STOP using the unit. Contact cus-tomer support for further instructions. Continuing to use the unit may cause serious damage.

FIXTURE LINKING

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all fixtures on a serial data link determines the number of fixtures that the data link can support.
Important: Fixtures on a serial/data link must be daisy chained in one single line. Maximum rec-ommended serial data link distance: 100 meters.

DATA CABLING

To link fixtures together you must use data cables. If you choose to create your own cable, please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.

CABLE CONNECTORS

Cabling must have a male XLR connector on one end and a female XLR connector on the other end.

DMX CONNECTOR CONFIGURATION

Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator.

You can power up to 5 units via the POWER IN/POWER OUT connectors from one single mains out-let. Connect an IEC cable from the POWER OUT connector of the 1st unit to the POWER IN connector of the second unit, etc.

CONTROL PANEL

To access the main menu press the MENU button. Press the UP or DOWN buttons until you reach function you wish to change. When you reach the function you wish to change, press the ENTER button. When a function is selected, use the UP or DOWN buttons to change the function settings. Once your changes are made, press the ENTER button.

FUNCTION MENU

Address Set| DMX Address setting|
---|---|---

Run mode

| DMX| Auto 1 – Auto2
AUTO|
SOUND|
MANUAL| Manual Test -> Function and Operation

SETUP

|

Advanced setting

| Pan reverse
Tilt reverse
Display
Screen Reverse
Channel (16/14/12/10 Select)
Sensitivity (01-100)
Motor zero
Reset
Factory Set

System     Infor- mation

| Ver V1|
DMX address
Temperature

PHOTOMETRIC DATA

CLEANING

Due to fog residue, smoke, and dust cleaning the internal and external lenses should be carried out periodically to optimize light output.

  • Clean regularly the air vents and fans.
  • Use normal glass cleaner and a soft cloth to wipe down the out-side casing.
  • Clean the external optics with glass cleaner and a soft cloth every 20 days.
  •  Always be sure to dry all parts completely before plugging the unit back in.

SPECIFICATIONS

  • Power supply: 90-240V~ 50/60Hz
  • Consumption: 250W
  • Fuse: 5A
  • Light source: White ultra-bright 180W LED
  • Beam angle: 15°
  • Dimensions: 270 x 270 x 470mm
  • Weight: 11.5kg