AFX LIGHT CLUB-MIX2 LED Par Can 12 X 12W RGBW with Dual Control User Manual
- June 9, 2024
- AFX LIGHT
Table of Contents
- AFX LIGHT CLUB-MIX2 LED Par Can 12 X 12W RGBW with Dual Control
- LED PAR CAN 12 X 12W RGBW WITH DUAL CONTROL
- SAFETY RECOMMENDATIONS
- CONTROL PANEL
- IR REMOTE CONTROLLER
- REMOTE CONTROL
- CLEANING AND USING FREQUENCY OF PRODUCT
- PHOTOMETRIC DIAGRAM
- TECHNICAL SPECIFICATIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AFX LIGHT CLUB-MIX2 LED Par Can 12 X 12W RGBW with Dual Control
LED PAR CAN 12 X 12W RGBW WITH DUAL CONTROL
FEATURES
- 12x 12W RGBW LED
- Separate control of the 9 outer and 3 inner LEDs
- 10/18 DMX channels
- Auto, DMX, master-slave, music and remote controlled operation
- Powercon in-/outputs
- IR remote control included
EXPLANATION OF SYMBOLS
- The triangle containing a lightning symbol is used to indicate whenever your health is at risk (due to electrocution, for example).
- An exclamation mark in a triangle indicates particular risks in handling or operating the ap-pliance.
- The unit complies with UK standards
- For indoor use only
- Protection class I. Requires an earth connection
- Minimum distance between the appliance and other objects Don’t stare into the light beam
CAUTION DO NOT OPEN THE HOUSING SHOCK HAZARD
SAFETY RECOMMENDATIONS
- Please read these instructions carefully, they include important information about the installa-tion, usage and maintenance of this product.
- Please keep this User Guide for future reference.
- Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the bottom of the fixture.
- The appliance is part of class I and must exclusively connected to an earthed mains outlet.
- This product is intended for indoor use only!
- To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating.
- The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.
- The minimum distance luminaire from that part of the luminaire or lamp to the lighted object is 0.5m. 0.5m
- The max. ambient temperature (Ta) is 40°C. Don’t operate the fixture at higher temperatures.
- The surface temperature of the unit may reach up to 85°C. DO NOT TOUCH the housing bare-hand during its operation. Turn off the power and allow about 20 minutes for the unit to cool down before replacing or servicing.
- DO NOT OPEN the unit within 5 minutes after switching off.
- In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type of spare parts.
- Make sure the power cord is never crimped or damaged.
- Avoid direct eye exposure to the light source while it is on as sensitive persons may suffer an epileptic shock (especially meant for epileptics)!.
- The product is for decorative purposes only and not suitable as a household room illumination.
- If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
- The lenses, housing or ultraviolet filter must be replaced if they are visibly damaged.
- Please note that the lamp of this device cannot be replaced. If the lamp is faulty, the unit must be discarded
DISCONNECT DEVICE
Please note that the unit DOES NOT have an ON/OFF switch. Please unplug the
unit to remove completele the power from the internal circuits before cleaning
or servicing. Therefore, the discon-nect device shall remain readily
accessible.
INSTALLATION
The unit should be mounted via its screw holes on the bracket. Always ensure
that the unit is firmly fixed to avoid vibration and slipping while operating.
Always ensure that the structure to which you are attaching the unit is secure
and is able to support a weight of 10 times of the unit’s weight. The
installation must always be secured with a secondary safety attachment, e.g.
an appropriate safety rope.Never stand directly below the device when
mounting, removing or servicing the fixture.
POWER SUPPLY AND SIGNAL CABLE CONNECTION
Mains Power connection
The exclusive plug should be used between the connection of unit and power.
Please ensure that the rated voltage and frequency are accordance with the
power supply. The required input voltage and frequency are: 90-240V~ 50/60Hz
We suggest that every light has an independent switch so that you can turn on
or turn off the light randomly.
- Note: the ground wire (yellow/green double-colour wire) must be safely connected, the electrical installation must be in accordance with the related standards
- CAUTION: When installing the device, make sure there is no highly inflammable material within a distance of min.5m!
Connection of Signal Cable
You can use the 3-pin XLR cable to connect the output socket of the master and
the input socket of the slave light. Connect the DIGITAL OUT socket of the
master and the IN socket of the slave light, then, connect the OUT socket to
the IN socket of the next light. Ordinal to connect all the lights as below
:
The connection between the output of master and input of product, it’s available to use the 3 pins XLR cable which provided by the manufacturer. Signal cable from the DMX output of the controller to the input of the first master light, and connect to the DMX input of second slave light from the DMX output of the first master light, analogously, till connected all the slave lights, and insert the last connector to the output of the final light. (Notice: the diameter of core of every cable should be 0.5mm at least, double core shelter cable should be used).The signal connecting must use the attached 3 pins XLR cable. Notice, all the internal lead wire of the 3 pins XLR cable should not touch to each other or connect to the connector. A DMX signal terminator is recommended on the last unit of the chain. DMX terminator is a XLR connector with a 120Ω resistor between the pin 2 and pin 3 of the XLR connector.
CONTROL PANEL
Use Menu button to choose a function among MODE, SET, DMX, REST, TEST and TEMP. Press Enter button to enter in the menu of the selected function Use Up and Down button to select the parameters then press Enter button to set the selected parameter Check the following function table :
MENU | DESCRIPTION |
---|
MODE
|
ADDR
| VALU| A001~A XXX (AXXX)| DMX address setting
SLAV| | | Stand-alone mode (Slave mode)
AUTO
|
IP1-8
| ALON /(AU-A)|
SP_1~SP_5 (Speed)
| Internal programme (alone) with speed control
MAST /AU-M)| Auto-run (Master) with speed control
SOUN
|
IP1-7
| ALON (SO-A)| Sound control (alone)
MAST/(SO-M)| Sound control (Master)
SET
| MIC| M-XX| | Mic sensitivity setting
LOAD| ON/OFF| | Reload data
VER| V-x.x| | Software version
CALI
| Code (password: 088)| Input password
CH03-CH06| Calibration
DMX
| MOD1| | | 18CH
MOD2| | | 10CH
REST| ON/OFF| | | Reset to factory default
MENU| DESCRIPTION
---|---
MANU
| rXXX| C000-255| | Manual control red LED
gXXX| C000-255| | Manual control green LED
bXXX| C000-255| | Manual control blue LED
UXXX| C000-255| | Manual control white LED
TEMP| TXXX| | | Current temperature
DMX channel chart: please refer to LAST page
IR REMOTE CONTROLLER
Please operate the remote control within a distance of 6m and 30° between the remote and the appliance. Aim the remote at the sensor. Remove all obstacles between the remote and the sensor. The remote control might not work properly if the sensor is exposed to strong sunshine. If the remote control doesn’t work properly, please check the batteries.
INSTALLING THE BATTERIES IN THE REMOTE CONTROL
- Place the remote face down on a flat surface.
- Push the compartment cover into the direction of the arrow.
- Slide the battery compartment open.
- Remove the old battery and install the new one (CR2025) with the plus (+) symbol facing up.
- Gently slide the battery compartment closed. It locks automatically.
RECOMMENDATIONS FOR BATTERIES
This symbol indicates that used batteries should not be disposed of with household waste but deposed correctly in accordance with your local regulations.. Batteries shall not be exposed to excessive heat such as sunshine, fire or the like. When the internal batteries are not to be used, remove them to avoid damage caused by battery leakage or corrosion.
- ATTENTION: Danger of explosion if battery is incorrectly placed. Only replace by the same or equivalent type.
- WARNING :Do not swallow the battery. Danger of chemical burns. Keep new and old batteries out of the reach of children. If the battery compartment doesn’t close properly, stop using the product and keep it out of the reach of children. If you are in doubt whether the batteries have been swallowed or introduced into any other part of the body, contact immediately a doctor.
REMOTE CONTROL
NOTE: PLEASE SET THE UNIT TO MODE -> ADDR, OTHERWISE THE REMOTE CONTROL WILL NOT WORK
- BRIGHTNESS & SPEED adjustment: Press to set the brightness and speed in program mode
- ON/OFF of the LEDs.
- SELECT BASIC COLOR: Red, Green, Blue or White (R+G+B)
- COLOUR BUTTONS: For constant lighting of all LEDs in one colour, press the corresponding button.
- SELECTING AN INTERNAL PROGRAMME:
- Flash: Colour switch
- Strobe: Colour strobe
- Fade: Colour fade
- Smooth: Colour switch and strobe
CLEANING AND USING FREQUENCY OF PRODUCT
Please make sure that the light is power off before dismantling or
maintaining, it’s very important to keep the light clean. Frequent cleaning
will ensure maximum brightness output, but also prolong the life time. It’s
suggested to use the high quality, professional glass detergent and soft cloth
to clean the light. It’s not allowed to use alcohol or chemical solvent. The
inner part of the light should
be cleaned by vacuum cleaner at least once a year. When the light doesn’t
work, please check if the fuse is burnt out or not. If it is, the same fuse
should be replaced, find out the faulty and restart the
light. But please note the repair must be handled by professional.
PHOTOMETRIC DIAGRAM
TECHNICAL SPECIFICATIONS
- Power Supply …………………………………………………………………………………………………………90-260V~50/60Hz
- Consumption ……………………………………………………………………………………………………………………………. 160W
- Light source ………………………………………………………………………………………………………..12 x 12W RGBW LED
- Beam angle ……………………………………………………………………………………………………………………………………26°
- Dimensions………………………………………………………………………………………………………….265 x 213 x 117mm
- Weight…………………………………………………………………………………………………………………………………….. 2.18kg
IMPORTANT NOTE: Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local authorities or your dealer about the way to proceed.
View the item on our website Copyright LOTRONIC 2022
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>