AFX LIGHT CLUB-MIX3 LED Par Can 19 x 10w RGBW User Manual

June 9, 2024
AFX LIGHT

AFX LIGHT CLUB-MIX3 LED Par Can 19 x 10w RGBW User Manual

AFX LIGHT CLUB-MIX3 LED Par Can 19 x 10w RGBW.JPG

CLUB-MIX3
CODE: 16-2049

Assembled in PRC
Designed by LOTRONIC S.A.
Av. Z. Gramme 9
B – 1480 Saintes

FEATURES

  • 19x 10W RGBW LED
  • Separate control of the 2 outer LED cercles and the inner LED
  • 12/30 DMX channels
  • Auto, DMX, master-slave, music and remote controlled operation
  • Powercon in-/outputs
  • IR remote control included

EXPLANATION OF SYMBOLS

FIG 2 EXPLANATION OF SYMBOLS.JPG

FIG 3 CAUTION.JPG

SAFETY RECOMMENDATIONS

  • Please read these instructions carefully, they include important information about the installation, usage and maintenance of this product.
  • Please keep this User Guide for future reference.
  • Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the bottom of the fixture.
  • The appliance is part of class I and must exclusively connected to an earthed mains outlet.
  • This product is intended for indoor use only!
  • To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating.
  • The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.
  • The minimum distance luminaire from that part of the luminaire or lamp to the lighted object is 0.5m. 0.5m
  • The max. ambient temperature (Ta) is 40°C. Don’t operate the fixture at higher temperatures.
  • The surface temperature of the unit may reach up to 85°C. DO NOT TOUCH the housing barehand during its operation. Turn off the power and allow about 20 minutes for the unit to cool down before replacing or servicing.
  • DO NOT OPEN the unit within 5 minutes after switching off.
  • In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type of spare parts.
  • Make sure the power cord is never crimped or damaged.
  • Avoid direct eye exposure to the light source while it is on as sensitive persons may suffer an epileptic shock (especially meant for epileptics)!.
  • The product is for decorative purposes only and not suitable as a household room illumination.
  • If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
  • The lenses, housing or ultraviolet filter must be replaced if they are visibly damaged.
  • Please note that the lamp of this device cannot be replaced. If the lamp is faulty, the unit must be discarded

DISCONNECT DEVICE

Please note that the unit DOES NOT have an ON/OFF switch. Please unplug the unit to remove completele the power from the internal circuits before cleaning or servicing. Therefore, the disconnect device shall remain readily accessible.

INSTALLATION

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight.

The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety rope.

Never stand directly below the device when mounting, removing or servicing the fixture.

POWER SUPPLY AND SIGNAL CABLE CONNECTION

FIG 4 POWER SUPPLY AND SIGNAL CABLE CONNECTION.JPG

1. Mains Power connection
The exclusive plug should be used between the connection of unit and power. Please ensure that the rated voltage and frequency are accordance with the power supply. The required input voltage and frequency are: 90-240V~ 50/60Hz

We suggest that every light has an independent switch so that you can turn on or turn off the light randomly.

Note: the ground wire (yellow/green double-colour wire) must be safely connected, the electrical installation must be in accordance with the related standards

CAUTION: When installing the device, make sure there is no highly inflammable material within a distance of min.5m!

2. Connection of Signal Cable
You can use the 3-pin XLR cable to connect the output socket of the master and the input socket of the slave light. Connect the DIGITAL OUT socket of the master and the IN socket of the slave light, then, connect the OUT socket to the IN socket of the next light. Ordinal to connect all the lights as below:

FIG 5 Connection of Signal Cable.JPG

The connection between the output of master and input of product, it’s available to use the 3 pins XLR cable which provided by the manufacturer. Signal cable from the DMX output of the controller to the input of the first master light, and connect to the DMX input of second slave light from the DMX output of the first master light, analogously, till connected all the slave lights, and insert the last connector to the output of the final light. (Notice: the diameter of core of every cable should be 0.5mm at least, double core shelter cable should be used).The signal connecting must use the attached 3 pins XLR cable. Notice, all the internal lead wire of the 3 pins XLR cable should not touch to each other or connect to the connector.

A DMX signal terminator is recommended on the last unit of the chain. DMX terminator is a XLR connector with a 120Ω resistor between the pin 2 and pin 3 of the XLR connector

CONTROL PANEL

Use Menu button to choose a function among MODE, SET, DMX, REST, TEST and TEMP. Press Enter button to enter in the menu of the selected function

Use Up and Down button to select the parameters then press Enter button to set the selected parameter

Check the following function table :

FIG 7 CONTROL PANEL.JPG

FIG 8 CONTROL PANEL.JPG

DMX channel chart: please refer to LAST page

IR REMOTE CONTROLLER
Please operate the remote control within a distance of 6m and 30° between the remote and the appliance. Aim the remote at the sensor. Remove all obstacles between the remote and the sensor.
The remote control might not work properly if the sensor is exposed to strong sunshine.
If the remote control doesn’t work properly, please check the batteries.

INSTALLING THE BATTERIES IN THE REMOTE CONTROL

  • Place the remote face down on a flat surface.
  • Push the compartment cover into the direction of the arrow.
  • Slide the battery compartment open.
  • Remove the old battery and install the new one (CR2025) with the plus (+) symbol facing up.
  • Gently slide the battery compartment closed. It locks automatically.

RECOMMENDATIONS FOR BATTERIES
This symbol indicates that used batteries should not be disposed of with household waste but deposed correctly in accordance with your local regulations..

Batteries shall not be exposed to excessive heat such as sunshine, fire or the like.
When the internal batteries are not to be used, remove them to avoid damage caused by battery leakage or corrosion.
ATTENTION: Danger of explosion if battery is incorrectly placed. Only replace by the same or equivalent type.
WARNING :Do not swallow the battery. Danger of chemical burns. Keep new and old batteries out of the reach of children.
If the battery compartment doesn’t close properly, stop using the product and keep it out of the reach of children.
If you are in doubt whether the batteries have been swallowed or introduced into any other part of the body, contact immediately a doctor.

REMOTE CONTROL

FIG 10 REMOTE CONTROL.JPG

CLEANING AND USING FREQUENCY OF PRODUCT

Please make sure that the light is power off before dismantling or maintaining, it’s very important to keep the light clean. Frequent cleaning will ensure maximum brightness output, but also prolong the life time. It’s suggested to use the high quality, professional glass detergent and soft cloth to clean the light. It’s not allowed to use alcohol or chemical solvent. The inner part of the light should be cleaned by vacuum cleaner at least once a year. When the light doesn’t work, please check if the fuse is burnt out or not. If it is, the same fuse should be replaced, find out the faulty and restart the light. But please note the repair must be handled by professional.

PHOTOMETRIC DIAGRAM

FIG 11 PHOTOMETRIC DIAGRAM.JPG

TECHNICAL SPECIFICATIONS

FIG 12 TECHNICAL SPECIFICATIONS.JPG

  • Power Supply…………………………………………………………………………………………………………90-260V~50/60Hz
  • Consumption……………………………………………………………………………………………………………………………. 200W
  • Light source………………………………………………………………………………………………………..19 x 10W RGBW LED
  • Beam angle……………………………………………………………………………………………………………………………………26°
  • Dimensions………………………………………………………………………………………………………….265 x 213 x 117mm
  • Weight…………………………………………………………………………………………………………………………………….. 2.18kg

IMPORTANT NOTE: Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local
authorities or your dealer about the way to proceed.

DMX CHANNEL CHART

FIG 13 DMX CHANNEL CHART.JPG

FIG 14 DMX CHANNEL CHART.JPG

FIG 15 DMX CHANNEL CHART.JPG

FIG 16 DMX CHANNEL CHART.JPG

FIG 17 QR Code.JPG

View the item on our website

© Copyright LOTRONIC 2022

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals