Winsen MC101 Catalytic Flammable Gas Sensor User Manual

June 9, 2024
Winsen

Winsen MC101 Catalytic Flammable Gas Sensor

Winsen MC101 Catalytic Flammable Gas Sensor-fig1

Statement

  • This manual copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the written permission, any part of this manual shall not be copied, translated, stored in database or retrieval system, also can’t spread through electronic, copying, record ways.

  • Thanks for purchasing our product. In order to let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly in accordance with the instructions. If users disobey the terms or remove, disa ssemble, change the components inside of
    the sensor, we shall not be responsible for the loss.

  • The specific such as color, appearance, sizes …etc .., please in kind

  • We are devoting ourselves to products development and technical innovation, so we reserve the right to improve the products without notice. Please confirm it is the valid version before using this manual. At the same time, users’ comments on optimized using way are welcome.

  • Please keep the manual properly, in order to get help if you have questions during the usage in the future. Zhengzhou

MC101 Catalytic Flammable Gas Sensor

Product
MC101 adopts catalytic combustion principle, and its two arms of electric bridge consists of a test element and a compensate element. The resistance of the test element rises once it meets the combustible gases, in the same time, the output voltage of the bridge changes and the voltage variation rises in direct proportion to the gas concentration. The compensate element, as a conference, has the function of compensating temperature and humidity.

Features

  • Bridge output voltage in linear
  • Fast response
  • Good repeatability and selectivity
  • Resist H2S poisoning & organosilicone.

Winsen MC101 Catalytic Flammable Gas Sensor-fig2

Main Applications
It is used in household occasion to detect the leakage or concentration of combustible gases such as natural gas, LPG, coal gas and so on.

Parameters

Model MC101
Sensor Type Catalytic Type
Standard Encapsulation Plastic
Working voltage(V) 3.0±0.1
Working current(mA) 110±10
Sensitivity (mV) 1% CH4
1% C3H8 30~70
Linearity ≤5%
Measuring range(%LEL) 0~100
Response Time (90%) ≤10s
Recovery Time (90%) ≤30s
Working Environment -40~+70℃ <95%RH
Storage Environment -20~+70℃ <95%RH
Lifespan 5 years

Winsen MC101 Catalytic Flammable Gas Sensor-fig3

Sensitivity and Response Feature

Winsen MC101 Catalytic Flammable Gas Sensor-fig4

Changing of output signal at different temperature

Winsen MC101 Catalytic Flammable Gas Sensor-fig5

Changing of output signal at different humidity

Winsen MC101 Catalytic Flammable Gas Sensor-fig6

Changing of output signal with different voltage supplying

Winsen MC101 Catalytic Flammable Gas Sensor-fig7

Long-term Stability
The drift in air per year is within ±2mV, in 1%CH4 is within ±2mV. For a short period storage (in 2 weeks), the sensor need be galvanical continuously for 8 hours to reach stability. For long period storage (one year), it need 48 hours.

Winsen MC101 Catalytic Flammable Gas Sensor-fig8

Cautions

Following conditions must be prohibited
  • Exposed to organic silicon steam
    Sensing material will lose sensitivity and never recover if the sensor absorbs organic silicon steam.
    Sensors must avoid exposing to silicon bond, fixature, silicon latex, putty or plastic contain silicon environment.

  • High Corrosive gas
    If the sensors are exposed to high concentration corrosive gas (such as H 2 S, SO X , Cl 2 , HCl etc.), it will not only result in corrosion of sensors structure, also it cause sincere sensitiv ity attenuation.

  • Alkali, Alkali metals salt, halogen pollution
    The sensors performance will be changed badly if sensors be sprayed polluted by alkali metals salt especially brine, or be exposed to halogen such as fluorine.

  • Touch water
    Sensitiv ity of the sensors will be reduced when spattered or dipped in water.

  • Freezing
    Do avoid icing on sensor’s surface, otherwise sensing material will be broken and lost sensitivity.

  • Applied higher voltage
    Applied voltage on sensor should not be higher than stipulated value, even if the sensor is not physically damaged or broken, it causes down line or heater damaged, and bring on sensors’ sensitivity characteristic changed badly.

  • Pins connection
    When the sensor is connecting to the circuit, one of detection part pins and one of compensation part pins connects as the signal output. The other one of detection part pins connects negative electrode, while the other one of compensation part pins connects positive electrode. The part with D mark is the detection one the other part with C mark is the compensation one showing on the bottom part of the sensor.

Following conditions must be avoided
  • Water Condensation
    Indoor conditions, slight water condensation will influence sensors’ performance lightly. However, if water condensation on sensors surface and keep a certain period, sensors’ sensitive will be decreased.

  • Used in high gas concentration
    No matter the sensor is electrified or not, if it is placed in high gas concentration for long time, sensors characteristic will be affected. If lighter gas sprays the sensor, it will cause extremely damage.

  • Long time storage
    The sensors resistance will drift reversibly if it’s stored for long time without electrify, this drift is related with storage conditions. Sensors should be stored in airproof b ag without volatile silicon compound. For the sensors with long time storage but no electrify, they need long galvanical aging
    time for stability before using. The suggested aging time is 24 hours at least if the storage time is more than half an year.

  • Long time exposed to adverse environment
    No matter the sensors electrified or not, if exposed to adverse environment for long time, such as high humidity, high temperature, or high pollution etc., it will influence the sensors’ performance badly.

  • Vibration
    Continual vibration will result in sensors down lead response then break. In transportation or assembling line, pneumatic screwdriver/ultrasonic welding machine can lead this vibration.

  • Concussion
    If sensors meet strong concussion, it may lead its lead wire disconnected.

  • Usage Conditions
    For sensor, handmade welding is optimal way. The welding conditions as follow:

    • Soldering flux: Rosin soldering flux contains least chlorine
    • Homothermal soldering iron
    • Temperature 3 50
    • Time less than 5 seconds
      If disobey the above using terms, sensors sensitivity will be reduced.