BANNER WLA-2 LED Area Light User Guide

June 9, 2024
BANNER

BANNER WLA-2 LED Area Light

BANNER-WLA-2-LED-Area-Light

Instructions

Important: Read the following instructions before operating the light. Please download the complete WLA-2 Area Light technical documentation, available in multiple languages, from www.bannerengineering.com for details on the proper use, applications, Warnings, and installation instructions of this device.

Models

Standard models shown. Contact factory for other options.

BANNER-WLA-2-LED-Area-Light-1

  • No lens option on encapsulated or diffuse window models.
  • No warm white option on encapsulated models.

Wiring Diagram

Male

Pin Wire Color Connection
1 Brown 12 V DC to 30 V DC
3 Blue DC common
    High/Low/Off Models:

Connect to 12 V DC to 30 V DC for 50% maximum intensity. For maximum intensity, leave the black wire floating or connected to common.

PWM Models:

Pulse width modulation (PWM) input. For maximum intensity, leave the black wire floating or connected to common. Connecting to 12 V DC to 30 V DC causes the LEDs to shut off.

 |
4| Black
2| White| Not used

Specifications

Supply Voltage

  • 12 V DC to 30 V DC
  • Use only with suitable Class 2 power supply (UL) or SELV power supply (CE).
  • See electrical characteristics on product label

LED Lifetime

  • Lumen Maintenance – L70
  • When operating within specifications, output will decrease less than 30%after 70,000 hours.

Supply Current

Housing Length (mm)

|

Max Current (A)

| Typical Current Draw (A)
---|---|---
12 V DC| 24 V DC| 30 V DC
105| 0.875| 0.830| 0.325| 0.260
190| 1.750| 1.660| 0.650| 0.520
275| 2.625| 2.490| 0.975| 0.780
360| 3.500| 3.320| 1.300| 1.040

Light Characteristics

  • Color Temperature (CCT): 5000K, 3000K
  • Lumen output: 1025 per panel, typical at 25 ºC (77 ºF) ambient 1
  • CRI: 80, minimum

Construction

  • Standard models: PBT housing, polycarbonate window, nickel-plated brass connector
  • Encapsulated models: PBT housing, nickel-plated brass connector, polyurethane encapsulated

Supply Protection Circuitry
Protected against reverse polarity and transient voltages

Connections

  • Integral 4-pin M12 male quick-disconnect connector (4-pin connecting cordset required)

Vibration and Mechanical Shock

  • Vibration: Vibration: 10 Hz to 55 Hz, 1.0 mm peak-to-peak amplitude per IEC 60068-2-6
  • Shock: Shock: 15G 11 ms duration, half sine wave per IEC 60068-2-27
  • Impact: IK07 (IEC 60068-2-75)

CertificationsBANNER-WLA-2-LED-Area-Light-3

Operating Temperature
Clear and Diffuse Window Models:

  • –40 °C to +70 °C (–40 °F to +158 °F)
  • Light output begins to decrease above 50 °C (122 °F), and decreases to approximately 65% of max intensity

Encapsulated Models:
20 °C to +50 °C (–4 °F to +122 °F)

Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F)

Environmental Rating

  • Suitable for wet locations per UL 2108 Clear and Diffuse Window Models:
  • Rated IP67 and IP69K per DIN 40050-9 Encapsulated Models:
  • Rated IP67, IP68, and IP69K per DIN 40050-9

Required Overcurrent Protection
WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations.

  • Overcurrent protection is required to be provided by end product application per the supplied table.
  • Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply.
  • Supply wiring leads < 24 AWG shall not be spliced.
  • For additional product support, go to www.bannerengineering.com.

Supply Wiring (AWG)| Required Overcurrent Protection (Amps)
---|---
20| 5.0
22| 3.0
24| 2.0
26| 1.0
28| 0.8
30| 0.5

**Dimensions

**

All measurements are listed in millimeters [inches], unless noted otherwise. BANNER-WLA-2-LED-Area-Light-4

Model L1 L2
WLA-2..105X 105.1 mm (4.14 in) 92.8 mm (3.66 in)
WLA-2..190X 188.9 mm (7.44 in) 176.7 mm (6.96 in)
WLA-2..275X 272.7 mm (10.74 in) 260.3 mm (10.25 in)
WLA-2..360X 356.6 mm (14.04 in) 344.3 mm (13.55 in)

Banner Engineering Corp. Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.

FCC Part 15 Class B

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Industry Canada
This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation.

Mexican Importer
Banner Engineering de Mèxico, S. de R.L. de C.V.
David Alfaro Siqueiros 103 Piso 2 Valle oriente
San Pedro Garza Garcia Nuevo Leòn, C. P. 66269
81 8363.2714
© Banner Engineering Corp. All rights reserved

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals