Dimplex CDFI500-PRO Built-in Electric Cassette User Guide
- June 9, 2024
- Dimplex
Table of Contents
Dimplex CDFI500-PRO Built-in Electric Cassette
We value your feedback!
Your input helps to create even betterproducts and experiences.
Share the warmth and leave a review. dimplex.com/sharethewarmth
IMPORTANT SAFETY INFORMATION:
Read this manual first before attempting to install or use this electric
fireplace. Always comply with the warnings and safety instructions contained
in this manual to prevent personal injury or property damage.
To view the full line of Dimplex products, visit
www.dimplex.com
Conventions used in this manual:
! NOTE: Procedures and techniques that are considered important enough to
emphasize.
CAUTION: Procedures and techniques which, if not carefully followed, will
result in damage to the equipment.
WARNING: Procedures and techniques which, if not carefully followed, will
expose the user to the risk of fire,serious injury, or death.
Welcome
Thank you and congratulations for purchasing an Opti-myst® cassette from
Dimplex.
Please carefully read and save these instructions.
WARNING: Read all instructions and warnings carefully before starting
installation. Failure to follow these instructions may result in a possible
electric shock, fire hazard and will void the warranty.
Please record your model and serial numbers for future reference.
Model
MOD
Serial Number
STOP NO NEED TO RETURN TO THE STORE
If you have questions regarding the operation of this product or if you
require service, before returning this product to the place of purchase,
Contact us at: www.dimplex.com/support
For Troubleshooting and Technical Support
OR Toll-Free 1-888-346-7539
Please have your model number and product serial number ready.
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
- Read all instructions before using the unit.
- Do not operate any unit if the unit has been dropped or damaged in any manner. Contact Technical Service at 1-888-346-7539.
- Do not use outdoors.
- Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
- Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a reputable electrician before reusing.
- To disconnect the unit, turn the controls OFF, disconnect power at the service panel.
- Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater.
- To prevent a possible fire, do not block air intakes or exhaust in any manner.
- All electrical heaters have hot and arching or sparking parts inside. Do not use in areas where gasoline, paint, or flammable liquids are used or stored.
- Do not modify the unit. Use it only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
- Do not burn wood or other materials in the unit.
- Always use a certified electrician should new circuits or outlets be required.
- Disconnect the power supply before performing any cleaning, maintenance or relocation of the unit.
- When transporting or storing the unit, keep in a dry place, free from excessive vibration and store so as to avoid damage.
WARNING: Remote control contains small batteries. Keep away from children. If swallowed, seek medical attention immediately.
- Do not install battery backwards, charge, put in fire or mix with used or other battery types – may explode or leak causing injury.
NOTE: Changes or modifications not expressly approved by the party responsible for compliance could void user’s authority to operate the equipment.
Technical Specifications
Electrical Rating
- Voltage: 120 V
- Power: CDFI500-PRO 230 W
CDFI1000-PRO 460 W
UL Listing
- File Number: E71416
Model Reference
CDFI1000-PRO| 6909660300
CDFI500-PRO| 6909660400
Product Dimensions
CDFI500-PRO
CDFI1000-PRO
Package Contents
Image | Description | Quantity |
---|---|---|
CDFI1000-PRO | CDFI500-PRO | |
Cassette | 1 | 1 |
Tethered Controller | 1 | 1 |
Remote | 1 | 1 |
AAA Batteries | 2 | 2 |
Transducers | 4 |
(2 installed)
| 2
(1 installed)
| Refillable Water Container| 2| 1
| Instruction Manual| 1| 1
| Flame Baffles| 4| 2
| Slotted Flame Baffles| 6| 3
| Wire Connectors| 3| 3
Installation
Air Inlets
A fresh air inlet that is a minimum of 80 inches² (516 cm²) for the
CDFI1000-PRO and 40 inches² (258 cm²) for the CDFI500-PRO, is required. The
air intake must allow for air to reach the underside of the Opti-myst Cassette
(Figure 1 & 2).
If installing into the Opti-Myst Pro Box (CDFI-BX100 or CDFI-BX1500), no additional air take is required.
Placement
NOTE: Optimal installation height is 60″ (152.4 cm) to the bottom of the media plate or log set. Installing the product above this height may reduce the flame visibility.
For optimal performance, a clearance of 18″ (457 mm) between the bottom of the media plate or log set and any surface above should be maintained. A minimum clearance of 16″ (405 mm) must be maintained.
The CDFI1000-PRO and CDFI500-PRO are supplied in an assembled state and are
designed to be permanently installed. The units come ready for hardwire
installation and the use of the water refill containers.
When determining a location for the Opti-myst® cassette, ensure that the unit
will not be susceptible to drafts, vents, ceiling fans and other air currents.
Similar to a candle, large movements of air will affect the unit’s ability to
create and maintain the flame effect. If the desired location is susceptible
to significant air movement, such as air vents, the different installation
options illustrated in Figure 1 (page 7) can be used. It is important that the
surface surrounding the top of the cassette have at least a 3″ (72 mm)
clearance from any vertical surface and the barrier be 10″ (254 mm) high from
the installation surface, to ensure optimal flame production.
Installation in a Bathroom
If this unit is installed in a bathroom, it must be protected by a GFCI
receptacle or circuit. If a receptacle is used, it must be readily accessible.
To prevent electrical shock this unit is an electrical appliance that is not
watertight and must be installed as to prevent water from entering the unit.
This unit must be installed away from showers, tubs, etc. Never locate
fireplace over a bathtub or other water containers. Keep towels and other
combustible materials 3 feet (0.9 m) away from the top of the unit.
Installation Instructions
Please read all instructions before installing.
WARNING:
- Failure to install the cassette as instructed below may result in damage to the equipment and or may expose the user to the risk of fire, serious injury, illness or death.
- Construction and electrical outlet wiring must comply with local building codes and other applicable regulations.
CAUTION: It is recommended that during drywall installation and finishing the media plate be installed with the provided bag to prevent dust and debris from entering the unit.
-
Use studs to frame an enclosure with the minimum internal/opening dimensions shown in Figure 3. Note that the media plate (supplied) and log set (optional, sold separately) require different opening widths.
NOTE: When preparing the opening for the unit ¼” (6.4 mm) of clearance should be maintained from each surface to ensure easy installation. -
If connecting to plumbing, complete the water connection according to the instructions in the ‘Cassette Plumbing’ section (page 10).
-
In the back left corner of the unit, locate and remove the electrical cover plate, by removing the two securing screws (Figure 4).
-
Complete the wiring according to instructions in the ‘Electrical Installation’ section (page 11). Reinstall the electrical cover plate after completing wiring.
NOTE: If using the optional power cord (CDFI-PLUGKIT, sold separately), follow the instructions provided with the kit. -
Install the unit into the rough-in framing ensuring that the unit is resting on two framing sills, one at the front and one at the back or a level surface. Ensure an air opening is maintained.
-
Level the housing – right to left and front to back, using the adjustable feet on the bottom of the unit.
-
Secure the unit to the permanent framing on either end through a minimum of two holes (Figure 4).
Cassette Plumbing
CAUTION:
- Ensure that all plumbing connections meet local plumbing code requirements.
- Ensure that the location of the plumbing connection allows for easy access to allow for shutoff during scheduled maintenance.
The units come equipped with refill containers for manual filling of the reservoir. The unit can be hard plumbed with the plumbing accessory kit – CDFIPLUMB-KIT, available from your local Dimplex dealer, or with standard ¼” (6.4mm) tubing. The plumbing accessory kit is designed for use with copper piping.
-
Locate a cold water line in the vicinity of the desired location of the cassette.
NOTE: Normal tap water can be used in the Opti-myst® as long as the tap water is not considered to be hard water. In the event your tap water is hard, softened or filtered water is recommended. -
Turn off the main water supply and drain the line of any standing water (if possible), before connecting the water line.
! NOTE : Once the new plumbing connections are complete, ensure that the lines are flushed to prevent any debris from entering the unit. -
Replace the top cover assemblies and ensure that the two plumbing caps are securely attached to the top cover of the water reservoirs. (Figure 13, page 16)
-
Locate the ball valve located in the bottom center of the unit (near the back) (Figure 5). Attach one end of
the ¼” (6.4 mm) tubing to the ball valve. Insert the tubing into the ball valve fitting so that it is fully inserted (approximately ½” [12 mm]).
NOTE : Ensure that the end of the tubing is cut square, to prevent leaking. -
Route the tubing to the area of the water source.
-
Verify that all of the connections are fully inserted, and begin opening each of the valves, ensuring that no leaks are present.
Connecting Multiple Units Together
When connecting multiple units together, the plumbing should be constructed in
a manifold style configuration, sized appropriately for the number of units
that are being installed so consistent water volume and pressure is being
supplied to each unit.
Electrical Installation
WARNING:
- Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician.
- Ensure that the On/Off switch is set to the ‘off’ position (refer to Operation section) and that the circuit on which the unit is to be installed has the power cut off at the service panel until installation is complete.
CAUTION: A 15 Amp, 120 Volt circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or the fuse blows on a regular basis when the cassette is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker.
Hardwired Installation
CAUTION: Use two conductor, non-metallic sheath cable with ground wire (3
wires total) for the incoming power supply on the cassette. Use appropriate
wire to meet local and national electrical codes for rated power.
- Install a 3/8 in (10 mm) or ½ in (13 mm) cable connector, not included, suitable for mounting in a 7/8 in (22 mm) hole, to the cable plate and feed the supply cable through the connector. The cable plate can be removed by removing the two securing screws on either side, to allow for easier access (Figure 4, page 9).
- Connect the black wire (live) from the unit to the live from the power supply.
- Connect the white wire (neutral) from the unit to the neutral wire from the power supply.
- Connect the green wire (ground) from the unit to the ground wire from the power supply.
- Place all connections inside the unit and secure the cable clamp to unit, making sure that the cable clamp grips only the jacket of service cable.
WARNING: Ensure the power wiring is not installed so that it is pinched or against a sharp edge and ensure that the power wiring is stored or secured to avoid tripping or snagging to reduce the risk of fire, electric shock or injury to persons.
Connecting Multiple Units Together
When installing multiple units in the same vicinity they will need to be wired
in parallel.
Wall Switch
The Opti-myst® cassette is designed to allow for installation of a wall switch
to control the incoming power to the unit. Use a single pole, single throw
(On/Off) wall switch that is rated for a minimum of 15 amps.
Operation Preparation
- After the drywall is installed and the surrounding area has been finished, remove the media plate from the unit.
- Unwrap the tethered controller and ensure that the wire is lead through the opening for plumbing connections (Figure 5, page 10). Position the tethered controller so that:
- a) it can be easily accessed, if being used as the main controls, or
- b) it is not obscured by either bricks, stone, or sheet metal to avoid obstructing the signal from the remote control.
- Initialize the tethered controller to the remote (see ‘Operation’ section, page 14).
- Fill the unit with water:
Refill Containers – remove the pre-installed pluming cap(s), then install the refill containers (Figure 13, page 16). During initial installation, each refill container should be refilled after the reservoir has filled to ensure the maximum operating time. Each refill container holds 42 oz. (1.25L).
Hard Plumbed – prime each of the water reservoirs with 32 oz (1L) of water. The water level should fall between the ‘High’ and ‘Low’ water indicators (Figure 6).
5. Install the media plate or log kit accessory (sold separately) on top. If using the log kit, connect the wire to the outlet on the cassette to power the inner LEDs (Figure 6).
! NOTE: If the unit is accessorized with something other than just the media plate or log set, ensure that media used does create small particles that may fall into the unit or have a overall weight above 10 lb (4.5 kg) for the CDFI500-PRO and 20 lb (9 kg) for the CDFI1000-PRO.
WARNING: This unit must be properly installed before it is used.
There are three different control options available for the unit: onboard
controls, tethered controller, and remote control.
! NOTE: When the unit is installed in an environment where background noise is very low, it may be possible to hear a sound which is related to the operation of the flame effect. This is normal and should not be a cause for concern.
- During normal operation it is expected to see some condensation of water on the media plate. This will vary depending on ambient conditions and should be considered normal.
Onboard Controls
The onboard controls are located under the media plate (Figure 7). The CDFI1000-PRO unit has two separate internal modules that are controlled by the settings entered on the left side (primary). Finer adjustment can be done using the controls on the right module to have both modules operating at the same level (secondary).
Remote Control and Tethered Controller
The tethered controller (Figure 8) can be used in the same manner as the
remote (Figure 9). The tethered controller must be connected to the unit and
the On/Off Switch must be in the ‘on’ ( I ) position in order for the remote
to operate.
NOTE: The remote control must be initialized with the unit prior to use. It is possible to synchronize up to 5 cassettes to one remote control.
Filling the Refillable Containers
CAUTION: Allow at least five minutes for components to cool before
disassembling the unit to refill.
When the water tank is empty, the flame effect will shut off and the LEDs will
blink twice continuously. Follow these steps to refill the tank:
-
Carefully remove the media and media plate.
-
Turn the On/Off switch to the ‘off’ position (0).
-
Remove the refill container by lifting upwards and outwards.
-
Refill the container with water.
NOTE: Normal tap water can be used in the Opti-myst® as long as the tap water is not considered to be hard water. In the event your tap water is hard, you may use softened water or distilled water. If using distilled water, it is recommended to add 1/8 tsp. of salt (0.5 mL) to the water reservoir; additional salt should only be when you notice that the unit is not producing mist as expected. -
Screw the cap back on. Do not overtighten.
-
Return the refill container to the sump, with the tank cap facing down and the flat side of the tank facing outward.
-
Turn the On/Off switch to the ‘on’ position ( I ).
-
Carefully place media plate and media back into position.
Flame Customization
The CDFI500-PRO and CDFI1000-PRO come with inserts that allow you to customize
the look of the flame. To use the spacers, first break them along the break
line (Figure 10). Second, insert into the nozzle at desired locations. It is
recommended to place them under any media that crosses through the flame, for
example, logs.
To use the slots, insert them into the nozzle (Figure 11). A total of 3 slot
inserts can be used in each nozzle.
Maintenance
Remote Control Battery Replacement
To replace the battery:
- Slide battery cover open on the remote control (Figure 12).
- Install two 1.5 Volt (AAA) battery in the battery holder.
- Close the battery cover.
Battery must be recycled or disposed of properly. Check with your Local Authority or Retailer for recycling advice in your area.
WARNING: Disconnect power and allow element to cool before attempting any
maintenance or cleaning to reduce the risk of fire, electric shock or damage
to persons.
CAUTION: If you need to move the unit ensure that all of the components
that contain water have been emptied before relocating.
NOTE: If you do not intend on using the unit for longer than 2 weeks, empty and drain the unit of water, and dry all of the wet components.
Cleaning
It is required that the top cover(s), sump(s), refillable water containers(s)
(if used), and transducer(s) are cleaned with soap and water on a regular
basis, at a minimum once per month. More frequent cleaning may be required
depending on water quality.
CAUTION: Do not put plastic components in the dishwasher.
The air filters can be removed and gently rinsed with water to clean and dried
on a towel before reinstalling. Reinstall the filter so that the coarse black
side of the filter is facing the back of the unit.
Use only a damp cloth to clean the surfaces of the unit. Do not use abrasive
cleaners.
Transducer Replacement
After prolonged use, the ability for the unit to produce mist may become
reduced. If cleaning does not improve the performance of the flame effect,
replacement of the transducer may be required. This unit comes with
replacement transducers. Additional transducers may be purchased at
www.dimplex.com/replacement-parts
(9601210100RP).
NOTE: To remove the transducer, release the retaining tab in the sump and
remove transducer.
Servicing
Except for installation and cleaning described in this manual, an authorized
service representative should perform any other servicing.
Troubleshooting
For more troubleshooting, consult the CDFI Service Manual which can be found at www.dimplex.com/product-downloads
Problem Cause So
Fireplace does not turn on with the onboard controls
|
No incoming power
| Ensure unit is wired correctly Check main disconnect panel
Ensure wall switch is on (if applicable)
---|---|---
Power switch has not been turned on| Put the power switch in the ‘on’ position
( I )
Standby button has not been pressed to turn on the flame effect| Press the
standby button until one beep is heard
Fireplace does not turn on with the remote control
| The remote control has not been initialized to the tetherred controller|
Follow initialization instructions in the ‘Operation’ section.
The batteries in the remote control are dead| Replace remote control batteries
Unit continuously blinks one time
|
Water level in the sump is too high
| Turn off the unit from the power switch. Remove enough water from reservoir so that level is below maximum level.
Unit continuously blinks twice
|
Water level in the sump is too low
| If using refillable containers, turn off the unit from the power
switch. Follow ‘Filling the Refillable Containers’ instructions in the Operation Section.
If using direct-plumbed, turn unit off with the power switch. Ensure ball
valve is open. Wait 10 seconds before turning back on.
Unit continuously blinks three times| Level sensor error| Turn unit off with
the power switch. Wait 10 seconds before turning back on.
If problem persists, consult the service manual.
Unit continuously blinks four times
| Fill cycle has timed out| Turn unit off with the power switch. Wait 10
seconds before turning back on.
If problem persists, clean water filter and inspect plumbing to make sure
pressure is adequate and nothing is obstructing water flow.
Wiring Diagram
Warranty
Two-Year Limited Warranty
Products to which this limited warranty applies
This limited warranty applies to your newly purchased Dimplex cassette. This
limited warranty applies only to purchases made in any province of Canada
except for Yukon Territory, Nunavut, or Northwest Territories or in any of the
50 States of the USA (and the District of Columbia) except for Hawaii and
Alaska. This limited warranty applies to the original purchaser of the product
only and is not transferable.
Products excluded from this limited warranty
Products purchased in Yukon Territory, Nunavut, Northwest Territories, Hawaii,
or Alaska are not covered by this limited warranty. Products purchased in
these States, provinces, or territories are sold AS IS without warranty or
condition of any kind (including, without limitation, any implied warranties
or conditions of merchantability or fitness for a particular purpose) and the
entire risk of as to the quality and performance of the products is with the
purchaser, and in the event of a defect the purchaser assumes the entire cost
of all necessary servicing or repair.
What this limited warranty covers and for how long
Products, other than fireplace surrounds (mantels) and trims, covered by this
limited warranty have been tested and inspected prior to shipment. Subject to
the provisions of this warranty, Glen Dimplex Americas Ltd. (herein called
Glen Dimplex Americas) warrants such products to be free from defects in
material and workmanship for a period of 2 years from the date of the first
purchase of such products as follows: (a) a repair or replacement warranty on
defective products or parts, including in-home services, for the first year
following the date of first purchase;
and (b) thereafter, a replacement of parts warranty on defective products and
parts (with no in-home services) for the 1 year period commencing on the first
anniversary of first purchase and ending on the second anniversary of the date
of first purchase.
Glen Dimplex Americas fireplace surrounds (mantels) and trims covered by this
limited warranty have been tested and inspected prior to shipment and, subject
to the provisions of this warranty, Glen Dimplex Americas warrants such
products to be free from defects in material and workmanship for a period of 1
year from the date of first purchase of such products. Warranty services do
not include in-home services.
The limited 2 year warranty period for products other than fireplace surrounds
(mantels) and trims and the limited 1 year warranty period for fireplace
surrounds (mantels) and trims also applies to any implied warranties that may
exist under applicable law. Some jurisdictions do not allow limitations on how
long an implied warranty lasts, so the above limitation may not apply to the
purchaser.
What this limited warranty does not cover
This limited warranty does not apply to products that have been repaired
(except by Glen Dimplex Americas or its authorized service representatives) or
otherwise altered. This limited warranty does further not apply to defects
resulting from misuse, abuse, accident, neglect, incorrect installation,
improper maintenance or handling, or operation with an incorrect power source.
What you must do to get service under this limited warranty
Defects must be brought to the attention of Technical Service at
1-888-346-7539. Please have proof of
purchase, catalogue/model and serial numbers available when calling. Limited
warranty service requires a proof of purchase of the product.
What Glen Dimplex Americas will do in the event of a defect
In the event a product or part covered by this limited warranty is proven to
be defective in material or workmanship during (i) the 2 year limited warranty
period for products other than fireplace surrounds (mantels) and trims, and
(ii) the 1 year limited warranty period for surrounds (mantels) and trims, you
have the following rights:
-
Limited warranty service will be performed solely by dealers or service agents of Glen Dimplex Americas authorized to provide limited warranty services.
-
For products (other than surrounds (mantels) and trims) for
the period ending at midnight on the first anniversary of the date of first purchase, Glen Dimplex Americas will in its sole discretion either repair or replace such defective product or part without charge. If Glen Dimplex Americas is unable to repair or replace such product or part, or if repair or replacement is not commercially practicable or cannot be timely made, Glen Dimplex Americas may, in lieu of repair or replacement, choose to refund the purchase price for such product or part. This limited warranty entitles the purchaser to on-site or in-home warranty services. Accordingly, Glen Dimplex Americas will be responsible for all labour and transportation costs associated with the repair or replacement of the product or part except as follows: (i) charges may be levied for travel costs incurred to travel to the purchaser’s site where the product is located if the purchaser’s site is beyond 30 miles (48 km) from the closest service depot of Glen Dimplex Americas dealer or service agent; and (ii) the purchaser is solely responsible for providing clear access to all serviceable parts of the product. -
For products (other than surrounds (mantels) and trims) for
the period commencing at 12:01 a.m. on the day after the first anniversary of the first purchase and ending at midnight on the second anniversary of the date of first purchase, this limited warranty entitles the purchaser to replacement parts only without charge. If Glen Dimplex Americas is unable to replace such part, or if replacement is not commercially practicable or cannot be timely made, Glen Dimplex Americas may, in lieu of replacement, choose to refund the purchase price for such part. The purchaser shall not be entitled to on-site or in-home warranty services.
The purchaser shall be responsible for all expenses incurred for the removal of the part and installation of the replacement part including, without limitation, all shipping costs and transportation costs to and from the authorized dealer’s or service agent’s place of business and all labour costs. Such costs shall not be the responsibility of Glen Dimplex Americas. -
For surrounds (mantels) and trims for the period ending at midnight on the first anniversary of the date of first purchase, Glen Dimplex Americas will in its sole discretion either repair or replace such defective surrounds (mantels) and trims or part thereof without charge. If Glen Dimplex Americas is unable to repair or replace such product or part, or if repair or replacement is not commercially practicable or cannot be timely made, Glen Dimplex Americas may, in lieu of repair or replacement, choose to refund the purchase price for such product or part. The purchaser shall not be entitled to on-site or in-house services. The purchaser is responsible for all expenses incurred for repair or replacement
of such product or part including, without limitation, all shipping costs and transportation costs to and from the authorized dealer’s or service agent’s business and all labour costs. Such costs shall not be the responsibility of Glen Dimplex Americas. -
On-site or in-home services not provided under this warranty may be performed at the purchaser’s specific request and expense at Glen Dimplex Americas then-current rates for such services.
-
For products (other than surrounds (mantels) and trims) for
the period commencing at 12:01 a.m. on the day after the first anniversary of the first purchase and ending at midnight on the second anniversary of the date of first purchase, this limited warranty entitles the purchaser to replacement parts only without charge. If Glen Dimplex Americas is unable to replace such part, or if replacement is not commercially practicable or cannot be timely made, Glen Dimplex Americas may, in lieu of replacement, choose to refund the purchase price for such part. The purchaser shall not be entitled to on-site or in-home warranty services.
The purchaser shall be responsible for all expenses incurred for the removal of the part and installation of the replacement part including, without limitation, all shipping costs and transportation costs to and from the authorized dealer’s or service agent’s place of business and all labour costs. Such costs shall not be the responsibility of Glen Dimplex Americas. -
For surrounds (mantels) and trims for the period ending at midnight on the first anniversary of the date of first purchase, Glen Dimplex Americas will in its sole discretion either repair or replace such defective surrounds (mantels) and trims or part thereof without charge. If Glen Dimplex Americas is unable to repair or replace such product or part, or if repair or replacement is not commercially practicable or cannot be timely made, Glen Dimplex Americas may, in lieu of repair or replacement, choose to refund the purchase price for such product or part. The purchaser shall not be entitled to on-site or in-house services. The purchaser is responsible for all expenses incurred for repair or replacement
of such product or part including, without limitation, all shipping costs and transportation costs to and from the authorized dealer’s or service agent’s business and all labour costs. Such costs shall not be the responsibility of Glen Dimplex Americas. -
On-site or in-home services not provided under this warranty may be performed at the purchaser’s specific request and expense at Glen Dimplex Americas then-current rates for such services.
What Glen Dimplex Americas and its dealers and service agents are also not
responsible for:
IN NO EVENT WILL GLEN DIMPLEX AMERICAS, OR ITS DIRECTORS, OFFICERS, OR AGENTS,
BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY. WHETHER IN CONTRACT, IN TORT,
OR ON ANY OTHER BASIS, FOR ANY INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY,
CONSEQUENTIAL, OR INCIDENTAL LOSS, COST, OR DAMAGE ARISING OUT OF OR IN
CONNECTION WITH THE SALE, MAINTENANCE, USE, OR INABILITY TO USE THE PRODUCT,
EVEN IF GLEN DIMPLEX AMERICAS OR ITS DIRECTORS, OFFICERS, OR AGENTS HAVE BEEN
ADVISED OF THE POSSIBILITY OF SUCH LOSSES, COSTS OR DAMAGES, OR IF SUCH
LOSSES, COSTS, OR DAMAGES ARE FORESEEABLE. IN NO EVENT WILL GLEN DIMPLEX
AMERICAS, OR ITS OFFICERS, DIRECTORS, OR AGENTS BE LIABLE FOR ANY DIRECT
LOSSES, COSTS, OR DAMAGES THAT EXCEED THE PURCHASE PRICE OF THE PRODUCT.
SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO
THE PURCHASER.
How State and Provincial law apply
This limited warranty gives you specific legal rights, and you may also have
other rights which vary from jurisdiction to jurisdiction. The provisions of
the United Nations Convention on Contracts for the Sale of Goods shall not
apply to this limited warranty or the sale of products covered by this limited
warranty.
Scan this QR code to view Opti-Myst Pro Overview and Set-Up videos.
1-888-346-7539 |
www.dimplex.com
In keeping with our policy of continuous product improvement, we reserve the
right to make changes without notice.
© 2021 Glen Dimplex Americas
References
- Leave a review | Dimplex
- Electric Fireplace & Heating Solutions | Dimplex
- Product Downloads | Dimplex
- Heating Product Registration | Dimplex
- Replacement Parts | Dimplex
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>