FERVE F-814 Battery and Alternator Tester Digital Instruction Manual
- June 9, 2024
- FERVE
Table of Contents
FERVE F-814 Battery and Alternator Tester Digital
BATTERY AND ALTERNATOR TESTER
250 x 145 x 210 mm
3,350 kg
PRECAUTIONS
- Read the instruction manual before using the FERVE F-814.
- Attention! Explosive gas.
- Avoid flames and sparks.
- Do not expose the equipment to rain.
- Use it in a well-ventilated place.
OVERVIEW
- Connection diagram and battery and alternator charge table (1).
- Connection diagram for battery discharge (2).
- Carrying handle.
- Red temperature indicator.
- Green discharge time indicator.
- Digital voltmeter.
- Supply clips.
- 250Aclip.
- Pushbutton-tip.
TESTING THE CHARGE LEVEL OF THE BATTERY
- Connect the supply clips to the positive terminal (+, red clip) and negative (-, black clip) of the battery.
- Consult the digital voltmeter.
- Compare the reading with the battery charge table.
TESTING THE BATTERY
-
Connect the supply clips to the positive terminal (+, red clip) and negative (-, black clip) of the battery.
-
Make sure the reading on the voltmeter exceeds 12.35. If the reading is lower, charge the battery for 15 minutes.
-
Connect the 250 A clip to one terminal of the battery.
-
Using the pushbutton-tip, press on the other terminal, observing the digital voltmeter, until the green discharge time indicator goes out
(10 seconds ~). -
• If, during the test, the digital voltmeter exceeds 9.00, the battery is correct.
-
If the reading is under 9.00 or the digital voltmeter goes out, the battery is faulty.
-
If continuous discharge tests are carried out, the red temperature indicator will light. In this case, leave the FERVE F-814 to rest until the red indicator goes out.
TESTING THE ALTERNATOR
- Connect the supply clips to the positive terminal (+, red clip) and negative (-, black clip) of the battery.
- Start the engine at 2,000 rpm.
- Consult the reading on the digital voltmeter and compare it with the alternator value table.
WARRANTY
FERVE warrants this device against all-defective or faulty manufacturing or parts for a period of 36 months as of the purchase date.This warranty excludes damages caused by mishandling, dirt and filth, improper connection or power, accidents and, in general, any damages arising from causes that are external to the device. Any other warranty performance agreed to by the distributor shall be the exclusive liability of this party.
Furthermore, this document does not COver wear or damage caused to other goods or assets as a result of a fault in the device under warranty.This warranty is only valid when accompanied by the original invoice or sales receipt. This warranty shall lose validity if the device is handled by personnel or shops not related to our technical service.
FERVE, .A
Ctra. de Calafell, 15-25 Apartado (P.O. Box) 7
43700 EI Vendrell (España)
Tel. +34 977 660 500 – Fax +34 977 661 160
www.ferve.com
ferve@ferve.com