Tektronix P6011 Passive Probe Instruction Manual
- June 2, 2024
- Tektronix
Table of Contents
Tektronix P6011 Passive Probe
WARRANTY
All Tektronix instruments are warranted against defective materials and workmanship for one year. Tektronix transformers, manufactured in our own plant, are warranted for the life of the instrument.
Any questions with respect to the warranty mentioned above should be taken up with your Tektronix Field Engineer.
Tektronix repair and replacement-part service is geared directly to the field,
therefore all requests for repairs and replacement parts should be directed to
the Tektronix
Field Office or Representative in your area. This procedure will assure you
the fastest possible service. Please include the instrument Type and Serial
number with all requests for parts or service.
Specifications and price change privileges reserved.
Copyright © 1965, new material copyright 1968 by Tektronix, Inc., Beaverton,
Oregon.
Printed in the United States of America. All rights reserved. Contents of this
publication may not be reproduced in any form without permission
of the copyright owner.
P6011 PROBE SECTION 1
GENERAL INFORMATION
The P6011 is o passive l X probe with o small diameter probe body for cozy
access to lest points of compact circuitry.
The probe consists of o probe body assembly and o coble with a BNC connector.
The coble is available in 3.5.fool, 6.fool, and 9-foat lengths.
CHARACTERISTICS
Input Capacitance
At 140 kHz the input copal, lance of lye 3.5- foot coble is 28 pF, the 6-foot
cable is 48 pF, and the 9-foot coble is 75 pF.
Voltage Rating
The maximum DC, AC peak, or DC and AC peak combined input voltage is 600 V.
See Fig.
1-2 for derating curves.
Risetime
The risetime of the probe alone, when driven by a 25-ohm source is lisle in
Table 1-1.
TABLE 1-1 Connecting
Cable
The cable is made with a special res, solve center which provides critical
damping of reflections.
Environmental Capability
The probe will operose normally at tempera lures to 75 ° C.
OPTIONAL ACCESSORIES
Tektronix
- Part No. Description
- 013-0084-00 BNC to Probe Adopter
- 017-0076-00 GR to Probe Adapter
- 131 -0258-00 Tesl Point Jack
- 175•0249-00 3 in. Ground Clip
- 175-0236-00 3 in. Ground Lead
USE OF ACCESSORIES
Pincher Tip
The pincher tip, which slides onto the probe body, provides a positive
connection to a test point.
Hook Tip
The hook tip provides a means of holding onto a test point when there is not
adequate room for the pincher tip.
Insulating Tube
When using the probe without one of the above tips, place an insulating tube
over the tip of the probe to avoid short circuits.
Ground Lead
The ground lead clips to the probe between the probe body and the cable
assembly.
Insulating Sleeve
When the ground lead is connected to the probe, place the insulating sleeve
over the exposed connection to avoid short circuits.
Miniature Alligator Clip
The insulated alligator clip screws onto the ground lead
Probe Holder
The probe holder provides a convenient means of storing the probe when not in
use. After connecting the probe to the instrument being used, place the wide
half of the probe holder around the cable and slide onto the tapered portion
of the cable assembly near the BNC connector. When the probe is not in use,
place the tapered portion near the probe body into the holder.
MAINTENANCE
The P6011 Probe is designed to withstand normal operation and handling and
should give many hours of continuous use without failure.
However, if the probe fails or breaks, replacement parts are available. See
Mechanical Parts List in Section 2.
Replacing the Cable Assembly
If the coaxial cable between the probe body and the BNC connector should fail,
the cable assembly is available complete with fittings and
cable reliefs. Replace the cable assembly as follows:
- Unscrew the BNC plug, using two 7/ 16 in. wrenches.
- Unsolder the contact pin.
- Remove the spacer insulator.
- Unscrew the probe body and sleeve assembly from the other end of the cable assembly.
- Unsolder the male plug from the cable.
- Install the new cable assembly by reversing the above procedure.
PARTS 11ST SECTION 2
PARTS ORDERING INFORMATION
Replacement ports ore available from or through your local Tektronix Field
Office.
Changes to Tektronix instruments are sometimes mode to accommodate improved
components as they become available, and to give you the benefit of the latest
circuit improvements developed in our engineering deportment. It is therefore
important, when ordering ports, to include the following information in your
order: Port number including any suffix, instrument type, serial number, and
modification number if applicable.
If a port you hove ordered hos been replaced with a new or improved port, your
local Tektronix Field Office will contact you concerning any change in port
number.
ABBREVIATIONS AND SYMBOLS
SPECIAL NOTES AND SYMBOLS
- xooo Port first added at this serial number.
- ooox. Port removed ofter this serial number.
- 000-000 Asterisk preceding Tektronix Port Number indicates manufactured by or for Tektronix, or reworked or checked components.
- Use 000-000 Port number indicated is direct replacement.
- Internal screwdriver adjustment.
- Front-panel adjustment or connector.
PROBE and STANDARD ACCESSORIES
PROBE PACKAGE
PROBE PACKAGE
- 1-9 010-0193-00 PROBE PACKAGE, P6011, 3.5 foot
- 010-0190-00 PROBE PACKAGE, P6011, 6 foot
- 010-0229-00 PROBE PACKAGE, P6011, 9 foot
package includes:
PROBE ONLY
- 1 010-0192 00 PROBE, P601 l, 3.S foot
- 010-0189-00 PROBE, P601 l, 6 fool
- 010-0228-00 PRO BE, P601 I, 9 fool
STANDARD ACCESSORIES
- 2 013-0090-00 HOOK TIP, retractable
- 3 175-0l2S-OO CABLE, ground lead, 12 inch
- 4 175-0124-00 CABLE, ground lead 5 inch
- 5 l 66-0404-00 TUBE, insulating, molded
- 6 ~4-0046’00 CLIP, probe
- 7 166-0433-00 X67.46 7009 SLEEVE, insulating, gnu , trip
- 166-0433-01 7010 TUBE, ,nsulalrng, molded
- 8 206-0114•00 TIP, probe
- 9 352-0090-00 2-2 HOLDER, probe
- 006-03S1 -00 BAG, plo111c, 4 x 6 in, he, (not shown)
- 070–0512-0l MANUAL, instruction !not shown)
- 367-0105-00 X6926 HANDLE, hook hop !not shown)
REPLACEABLE PARTS (3.5 foot)
REF.
NO.
| TEKTRONIX
PART NO.
| SERIAL/ MODEL NO.
EFF. DISC.
| T
Y.
| DESCRIPTION
1 2 3 4 s
---|---|---|---|---
l| 010-0192-00
– – – – – –
204-0252-01| | | PROBE, P601 l, 3.5 foot probe includes: ASSEMBLY, body and
sleeve
2| 214-0592-00| | | PLUG, male
3| 210-0997-00| | | WASHER, guide
4| 361-0022-00| | | SPACER
5| 214-0109-01| | | Pl N, contact
6| 358-0072-00| | | BUSH I NG, insulator
7| 134-0044-00| | | PLUG, probe
8| 175-0337-03| | | CABLE, ASSEMBLY, 3.5 foot
| 200-0372-00| | | CAP, plastic protective (not shown)
| 015-0201-00| | | ADAPTER, probe tip, IC test (not shown)
REPLACEABLE PARTS (6 foot)
REF. TEKTRONIX NO. PART NO.
SERIAL / MODEL NO . EFF. DISC.
Q T
1 2 3 4 s
DESCRIPTION
1
| 010-0189-00
– – – – – –
204-0252-01| PROBE, P6011, 6 foot probe includes, ASSEMBLY, body and sleeve
---|---|---
2| 214-0592-00| PLUG, male
3| 21 0-0997-00| WASHER, guide
4| 361-0022-00| SPACER
5| 214-0109-01| PIN, contact
6| 358-0072-00| BUSHING, insulator
7| 134-0044-00| PLUG, probe
8| 175-0337-02| CABLE ASSEMBLY, 6 foot
| 200-0372-00| CAP, plastic, protective (not shown)
| 015-0201-00| ADAPTER, probe tip, IC test (not shown)
REPLACEABLE PARTS 19 foot}
REF. NO.| TEKTRONIX PART NO.| SERIAL/ MODEL NO. EFF. DISC.| Q
T
Y.
| ****
DESCRIPTION
1 2 3 4 s
---|---|---|---|---
| ****
010-0228-00
– – – – – –
1 204-0252-01
| | | ****
PROBE, P6011, 9 foot probe includes, ASSEMBLY, body and sleeve
| 2 214-0592-00| | | PLUG, male
| 3 210-0997-00| | | WASHER, guide
| 4 361-0022-00| | | SPACER
| 5 214-0109-01| | | PIN, contact
| 6 358-0072-00| | | BUSHING, insulator
| 7 134-0044-00| | | PLUG, probe
| 8 175-0471-00| | | CABLE ASSEMBLY, 9 foot
| 200-0372-00| | | CAP, plastic, protective (not shown)
| 015-0201-00| | | ADAPTER, probe tip, IC test [not shown)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>