cudy GS2024PS4 Commercial Series Switches User Manual

June 2, 2024
cudy

cudy GS2024PS4 Commercial Series Switches

udy-GS2024PS4-Commercial-Series-

Description

  • The products described in this manual, including but not limited to the illustrated products, please refer to the actual product purchased. If any changes to the product appearance, please refer to the official product information
  • Management switch connect and login methods are basically the same, this manual only introduces one of them
  • PoE switch and ethernet switch installation methods are the same, the actual use environment and method depend on the specific product requirement

Packing List

  • Switch(Specific model See the product label for more details)
  • Power Cable(The default is pluggable or a power cable with a built-in power module) Power Adapter(Use for some external power products)
  • Console Cable, Configurable Disc(Use for managed products)
  • Brackets, Screw(Rack type standard, desktop type optional)
  • User manual, Certification

Installation Precautions

  • Do not install the equipment in an environment of seepage, drip or condensation easily, otherwise, the equipment might burn out
  • Please ensure the environment where the equipment is installed is well ventilated, and forbidden to block the cooling holes
  • Do not install the equipment in a high-density dust environment
  • If rack switches are in a natural heat dissipation environment, please ensure the separation distance exceeds 1U
  • Do not aerial cabling outdoors, otherwise, the equipment is prone to lightning strikes Use temperature and humidity depending on the descriptions of the specific product

Safety Precautions

  • Do not look directly at the optical port to prevent the laser beam from burning your eyes
  • Do not install the power cord with power on to avoid personal injury
  • Do not supply power before equipment installation and wiring
  • ESD protection is necessary during the installation and maintenance of equipment
  • Do not place objects on the device

Switch Installation

  • Switches support a variety of installation methods, desktop, wall mounted, and rack mount, please install according to the actual environmental requirements
  • Mounting Ear Installation

Rack Mount Installation

  1.  Install 4 floating screws on the front hole bar of the cabinet, 2 on each side
  2.  Load the equipment into the cabinet
  3.  Use M6 screws to secure the equipment with the cabinet/rack
  4.  Install earth wire to the earth connection point

Connecting Equipment

  1.  When the RJ45 port is on 2.5GE rate, use Cat5E and above network cable
  2.  When the RJ45 port is on 5GE rate, a shielded network cable of Cat5E and above specifications is required, the unshielded network cable is not recommended
  3.  When the RJ45 port is on 10GE rate, a shielded network cable of Cat6A and above specifications is required

Grounding
Ensure that the grounding screw of the equipment is effectively grounded to protect the safety of the equipment

  1. Optical fibers must be used with the optical modules Fiber bending radius must not be less than 40 mm Power Cable
  2.  The distance between the power cable and the network cable should be more than 10cm
  3.  Regarding The AC power please use the local AC power cable
  4.  Regarding The DC power please pay attention to the positive and negative electrodes Console、USB
  5.  Some switches provide USB interfaces for uploading and downloading configuration files to achieve the rapid configuration
  6.  The console interface needs to use the serial line in the package to realize the serial port management

Login Management
This content is only applicable to the managed type of products, please read this helpful information for the first application

  1.  Connect the device and PC, to ensure that the device initialization is complete.
  2.  Configure the IP address of the PC to be in the same network segment as the switch default IP address
  3.  Enter “https://192.168.2.1” in the address bar of the opened PC browser, then press “enter” to the web management login interface, input the default user name “admin” and password”admin”, and press “enter”.

Console Port Management

  1.  Connect the PC and the switch console port with the console cable.
  2.  Start the terminal simulation software, create a connection, select a serial port, and set communication parameters inconsistent with the default configuration of the switch’s console port, as listed below:
    • Transmission rate: 115200 Data bits: 8
    • Parity bit: None
    • Stop bits: 1
    • Flow control mode: None
  3. Press Enter until the simulation terminal appears as follows, prompting the user to enter the user name and password. The default user name and password at first login is “admin”.

Indicator Definition

Indicator Definition State Description
PWR Power Indicator Light on Light off Powered Abnormal
SYS System Indicator Light on Flash System Normal System Starting
PoE PoE Indicator Light on

Light off

| PoE Powered

No PoE Powered

1000M| Link Rate| Light on

Light off

| Gigabit 10/100M
100M| Link Rate| Light on Light off| 100M

Link Disconnect

Link/ACT| Link &Data| Light on Flash| Link is Normal Data Transmission
Mode/SW| Dial Switch Indicator| Light on Flash Light off| VLAN

Extend Default

Loop| Loop Alarm| Light on| Port Loop

PoE Powered Function

This function is applicable to PoE switches, not applicable to non-PoE switches Standard PoE Power Supply

  1. Standard PoE power supply includes: protocol detection, power pin sequence detection, power output, abnormal protection, Link abnormal monitoring
  2.  The PoE power supply protocol includes: IEEE802.3af (15.4W), IEEE802.3at (30W), IEEE802.3bt (90W)
  3.  The standard PoE power pin sequence is 12+/36-, and the passive PoE power pin sequence is 45+/78-
  4.  Passive PoE switches use mandatory power supply mode, non-PoE powered devices may be burned out, please use them with caution
  5.  24V POE switches have both low-voltage power supply and PD detection technology, which can provide 24V voltage on a 45/78 pin, even if it is connected to non-standard equipment, it will not burn out

States of Switch

Function Definition State Description
VLAN Port Isolation Light on Designated port can

not communicate

with each other

Extend| Link Extension| Flash| Designated port link

extended to 250

meters

Default| Normal Mode| Light off| All ports can

communicate with

each other

Reset| Reset Button| Flash| Short press restart, long press more than 5 seconds reset

configuration

AI PoE           PoE                                 PDs crashed and

Watchdog/restart automatically

Max| Power| Green| PoE Power output≤25%
 | Display| Yellow| PoE Power output≤50%
 | Indicator| Orange| PoE Power output≤75%
 |  | Red| PoE Power output≥75%

Commercial Series Switches

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

cudy User Manuals

Related Manuals