IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS
BEFORE INSTALLATION
This fixture operates on regular household power (120V, 60Hz).
This fixture needs to be grounded.

Disconnected the power at the breaker panel before installing this product.

GENERAL INSTRUCTIONS
Electrical connections must be made in accordance with local electrical codes and regulations.
Consult a qualified electrician to ensure correct branch circuit conductor.

Tools Required

  • Screw driver
  • Recessed lighting hole
  • saw (recommended)
  • Cable Clamp
  • Wire Strippers
  • Pencil

Package Content

FIG 1 Package Content

WARRANTY

This product is warrantied to be free from defects in workmanship and materials for up to five years from date of purchase. If the product fails within the warranty period, replacement or refund is your sole remedy. Except to the extent prohibited by applicable law, any implied warranties are limited in duration to the duration of this warranty. Liability for incidental or consequential damages is hereby expressly excluded. Some states and provinces do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

WARNING

  • Risk of fire or electrical shock. LED Panel installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. The use of a licensed electrician is highly recommended. , As with all electrical components there is always a risk of fire or electric shock if handled and/or installed incorrectly.
  • Disconnect power at circuit breaker panel before any installation.
  • Install this product only in situations as per the general instructions above.
  • Do not make or alter any open holes in any enclosure or any electrical component during installation.
  • To prevent wiring damage or abrasion to the wires do not expose wiring to sharp edges of sheer metal or other sharp objects. , Do not use when the enclosure is damaged or broken in any way.
  • Do not alter, relocate or remove wiring, lamp holder power supply or any other electrical component.
  • Minimum operating temperature 4°F (-15.5°(). Lamp life may be affected outside these temperatures.

PRE-INSTALLATION REVIEW

  • Turn the power OFF from the breaker panel before starting installation.
  • Locate a suitable location for the fixture and cut the correctly sized hole in the drywall or ceiling tile (for a suspended T-Bar type ceiling) – refer to Hole Cut Out Template for appropriate size.
  • Know the location of your joist before making any cuts.
  • Run electrical wire from the switch (power supply) through the mounting hole; use NMD90
  • Romex or Flexible Metal Conduit Cable.
  • Use the slide switch to choose a preferred color temperature before installing – 2700K, 3000K, 4000K, 5000K, 6500K.

INSTALLATION INSTRUCTIONS FOR RECESSED HOUSING

FIG 2 INSTALLATION INSTRUCTIONS FOR RECESSED HOUSING

FIG 3 INSTALLATION INSTRUCTIONS FOR RECESSED HOUSING

FIG 4 INSTALLATION INSTRUCTIONS FOR RECESSED HOUSING

NOTE

This product will operate smoothly with most residential dimmers and provide continuous dimming from 100% brightness to a low of 10% of original light density. Be aware that many different dimmer technologies exist and some might not dim LED products and some might only work partially. This product has been tested and here are some of the dimmers with which this unit is compatible: Lutron MACL-153, Eaton SUL06P, Lutron DVCL-153. See Lowes.com for more information.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Any changes or modifications not expressly approved by the manufacture could void the user’s authority to operate the equipment. Feit Electric Company, 4901 Gregg Road, Pico Rivera, CA 90660. www.feit.com.

SUITABLE FOR WET LOCATIONS.
THE FOAM INSERT BETWEEN THE TRIM AND CEILING OF THIS PANEL WILL CREATE AN AIR TIGHT SEAL AND IS REQUIRED FOR THE ASTM AIR TIGHT CERTIFICATION.
SUITABLE FOR TYPE IC.
CONTINUOUS DIMMING BETWEEN 10%-100% WITH MOST DIMMERS; SEE LOWES.COM FOR MORE INFORMATION.

FIG 5 LIGHTING DISTRIBUTION

* WIRE GUAGE AND STRIP LENGTH REQUIREMENTS

FIG 6 WIRE GUAGE AND STRIP LENGTH REQUIREMENTS

SAVE THESE INSTRUCTIONS

IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY/ IMPORT ANTE, CONSERVE PARA FUTURA REFERENCIA: LEA CUIDADOSAME

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

UtiliTech User Manuals

Related Manuals