PRODUCT SPECIFICATION
100.28
100.28 Hand Blown Glass Pendants
PENDANTS: | twenty-eight |
---|---|
MOUNTING: | white powder coated square canopy 755mm (29.7”) x 53mm (2”) deep |
LAMPING: | 1.5w LED (2000K, 2500K, 3500K) |
COAX: | fixed lengths. 3000mm (10’) standard / up to 30500mm (100’) maximum |
MATERIALS: | blown glass, braided metal coaxial cable, electrical components, |
white powder coated canopy
WEIGHT:| approximately 87kg (191.8lb)
POWER SUPPLIES:| integral
DESCRIPTION
100.28 is a random configuration of twenty-eight 100 pendants hung from a
square canopy. The drop lengths of the pendants are randomized between a
client specified range of heights to variously cluster and scatter. The result
is an ambient installation or field of light.
100 brings multiple glass artists together in a performative act. Molten glass
bubbles are prepared and then smashed together to produce unpredictable
interlocking glass forms.
NOTES
+ Purchase replacement lamps online at www.bocci.com/shop/bulbs
+ All chandeliers will be outfi tted with 2500K lamps if not specifi ed.
+ As an alternative to a built-in power supply, Bocci recommends mounting
Power supplies remotely in an easily accessible and hidden location for ease
of long-term maintenance.
Note: All connections and power supplies are tested by our technicians before
shipping. However, it is possible for ports/power supplies to come loose or
damage during shipping.
Test each port before installing canopy to ceiling to catch any loose
connections or faulty power supplies.
Measure and mark the light fixture canopy position on the ceiling
Note: The client is responsible for providing a robust 16mm (5/8”)
plywood backing or wood blocking to securely anchor to the structural
substrate.
Connections from the plywood to the structural substrate are the client’s
responsibility.
Measure the plywood so that it fits within the canopy side walls (refer to
detail above). Anchor the plywood backing to the structural ceiling substrate.
Connect power supplies to line voltage. Connect the black wire to black and
white wire to white wire.
For the ground connection, connect the green wire with yellow stripe to the
bare copper wire or green wire in the junction box.
Note: Bocci strongly recommends mounting power supplies remotely in a
close, accessible and hidden location for ease of long term maintenance.
Installation to be done by certified personnel to insure compliance with the
code.
Anchor canopy into the plywood backing using the fasteners provided.
Turn power to fi xture on.
Very carefully uncoil the braided coaxial cable in a spool like manner. Insert
your index fingers into opposite sides of the roll then rotate your fingers
around each other to unroll the coaxial cable.
Use patience: allow the cable to uncoil completely to avoid kinks.
Step 1: Attach the lamp holder to the pendant hardware with set screw
provided.
Plug the lamp into lamp holder and slide on the diffuser. Do not touch the
lamp with your bare hands. Ensure power to lamp is working correctly.
Each pendant terminates in a “headphone jack” type connector, which plugs into
a receiving receptacle in the canopy. Clients are encouraged to compose their
own pendant confi guration on site, thus creating a truly unique fixture. After
plugging in each pendant, turn the threaded sheath into place by hand ensuring
that it is adequately tightened. Tools are not required.
Check that each lamp is working properly as you go along by keeping power to
the fixture on and lamps plugged in.
Please note that the crisp cut edges of the 100 pendants are fragile and can
chip if not handled with care when installing and cleaning.
Please ensure they do not have impact during hanging. Best practice is to
install from one side of the fixture to the other.
Bocci recommends wearing gloves during the installation. The edges of the
glass may be sharp to handle.
Step 2: Insert the pendant hardware assembly into the pendant.
Step 3: Tighten the 3 screws until they are fully engaged (refer to
illustration above).
Give the pendant a gentle pull to ensure the screws are locked onto the
pendant.
Slide cover cap onto the coaxial cable and place into the inset portion of the
pendant hardware.
The cap should sit flat on the pendant hardware.
If the screws are sticking out and the cap isn’t sitting flat on the pendant
hardware, please check to ensure the screws are fully engaged.
Refer to step 8 & 9 for more details.
Clean fingerprints from surfaces.
For additional assistance, please contact Bocci:
Vancouver
sales@bocci.com
www.bocci.com
Berlin
europe@bocci.com
www.bocci.com
US Patent Pending
EU Patent # 008526131-0001
Made in Vancouver, Canada
© 2021, Bocci Design and Manufacturing Inc. All rights reserved. Any inquiries should be directed to: info@bocci.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>