BOCCI 100.3 3 Blown Glass Pendants Instruction Manual

June 4, 2024
BOCCI

BOCCI 100.3 3 Blown Glass Pendants

BOCCI 100.3 3 Blown Glass Pendants
product

Dimensions

BOCCI 100.3 3 Blown Glass Pendants fig
1

PENDANTS: three
MOUNTING: roundl canopy 152mm (6”) in diameter x 32mm (1.3”) deep
LAMPING: 1.5w LED (2000K, 2500K, 3500K)
COAX: adjustable 3000mm (10’) standard / up to 30500mm (100’) maximum
MATERIALS: blown glass, braided metal coaxial cable, electrical components, brushed nickel canopy
WEIGHT: approximately 7.7kg (17lb)
POWER SUPPLIES: integral

DESCRIPTION

100.3 is a random confi guration of three 100 pendants hung from a round canopy. The pendants are designed to hang in a random confi guration, the result is an ambient installation or fi eld of light. The pendant drop lengths on this light fi xture are adjustable up to the specifi ed maximum.
100 brings multiple glass artists together in a performative act. Molten glass bubbles are prepared and then smashed together to produce unpredictable interlocking glass forms.

NOTES

  • Purchase replacement lamps online at www.bocci.com/shop/bulbs
  • All chandeliers will be outfi tted with 2500K lamps if not specifi ed.
  • As an alternative to a built-in power supply, Bocci recommends mounting Power supplies remotely in an easily accessible and hidden location for ease of long-term maintenance.

US Patent Pending
EU Patent # 008526131-0001
Made in Vancouver, Canada

sales@bocci.com
www.bocci.com

europe@bocci.com
www.bocci.com

Installation

  1. Very carefully uncoil the braided coaxial cable in a spool like manner. Insert your index fi ngers into opposite sides of the roll then rotate your fi ngers around each other to unroll the coaxial cable.
    Use patience: allow the cable to uncoil completely to avoid kinks.

  2. Determine the overall drop for the pendant fi xture.

  3. Thread the coaxial cables through the canopy, use a 2mm Allen key to loosen the setscrew in the canopy and gently feed the cable through until you have reached your desired drop length.
    Use Allen key to tighten the setscrew to hold the strain relief and secure the coaxial cable at its new length. Perform a gentle tug test to ensure it is secure.
    DO NOT OVERTIGHTEN.
    Note: The strain relief is a black plastic collar around the coaxial cable. There
    is a single slot opening on the side of the strain relief component. It is essential that this opening is oriented at 90 degrees to set screw chamber. There can be no contact between the set screw and the cable.
    RISK OF ELECTRIC SHORT!

  4. Connect the black wire to black and white wire to white wire.
    Connect the coaxial cable to the open slots in the terminal block on the 12V side of the power supplies.
    Ensure that the braided outer wires are all connected to one 12V output wire and all inner insulated wires are connected to the other or a short will occur.
    Once all coaxial connections are made, lift the fi xture into position and connect the line voltage to the open slot in the appropriate terminal block.BOCCI 100.3 3 Blown Glass Pendants fig 5

  5. The client is responsible to ensure fasteners are attached to a robust structural substrate.
    Tuck the power supply and wiring into the canopy. Line up the fastener holes or connect directly to structural ceiling surface using the fasteners provided.
    Turn power to fi xture on.

  6. Please note that the crisp cut edges of the 100 pendants are fragile and can chip if not handled with care when installing and cleaning.
    Please ensure they do not have impact during hanging. Best practice is to install from one side of the fi xture to the other.
    Bocci recommends wearing gloves during the installation. The edges of the glass may be sharp to handle.BOCCI 100.3 3 Blown Glass Pendants fig
7

  7. Step 1: Attach the lamp holder to the pendant hardware with set screw provided.
    Plug the lamp into lamp holder and slide on the diffuser. Do not touch the lamp with your bare hands. Ensure power to lamp is working correctly.

  8. Step 2: Insert the pendant hardware assembly into the pendant.
    Step 3: Tighten the 3 screws until they are fully engaged (refer to illustration above).BOCCI 100.3 3 Blown Glass Pendants fig
9

  9. Give the pendant a gentle pull to ensure the screws are locked onto the pendant.
    Slide cover cap onto the coaxial cable and place into the inset portion of the pendant hardware.BOCCI 100.3 3 Blown Glass Pendants fig
10

  10. The cap should sit fl at on the pendant hardware.
    If the screws are sticking out and the cap isn’t sitting flat on the pendant hardware, please check to ensure the screws are fully engaged.
    Refer to step 8 & 9 for more details

  11. Clean fi ngerprints from surfacesBOCCI 100.3 3 Blown Glass Pendants fig 11

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>