Futaba BR-4000 Battery Servo & Receiver Checker Instruction Manual
- June 3, 2024
- Futaba
Table of Contents
Futaba BR-4000 Battery Servo & Receiver Checker
Thank you for purchasing the BR-4000. This product is specifically designed for RC, not appliances in other areas. The total voltage of the battery pack is displayed, and the bar graph and percentage of the remaining amount are displayed. In the case of a lithium battery pack with a balance connector, it is also possible to display the voltage for cach cell. Futaba accepts no liability for damage, injury, or any legal responsibility incurred directly or indirectly from the use of this product. We strongly recommend you read our user’s guide before using BR-4000.
Warnings and safety notes
Securely use this product. Please observe the following safety precautions at all times.
Explanation Of Symbols
Please observe the following precautions to ensure the safe use of this product. Meaning of Special Markings: The parts indicated by the following marks in this manual require special attention from a safety standpoint.
- Procedures which may lead to a high probability of dangerous conditions and cause death/serious injury, if not carried out properly.
- Procedures which may lead to dangerous conditions or cause death/serious injury to the user if not carried out properly, or procedures where.
- Procedures where the possibility of serious injury to the user is small, but there is a danger of injury or physical damage, if not carried out properly.
- When there is a possibility of ignition under certain conditions.
- Symbols:
- : Prohibited
- : Mandatory
Warning
Fire Hazard!
Never use this product near flammable materials
- It is very dangerous if sparks occur when connecting or disconnecting the battery.
- Before using it, be sure to read all warnings and instructions regarding this product and your battery.
- Before connecting the battery, pay attention to the battery safety warning and ensure all parameters are set correctly.
- Incorrect settings can cause fire, property damage, or personal injury.
- Be sure to remove the battery after use.
- If it is connected for a long time, it is very dangerous if it catches fire due to over-discharge
- Be careful not to pinch the battery cord or short it.
- If it is short-circuited, the battery may overheat or catch fire.
Caution
- Keep this product away from heat sources and humid environments during use. Ventilation and heat dissipation are required.
- Do not connect a battery with an output voltage value that exceeds the operating range voltage of this product.
- Never get this product wet.
- The inside is a precise electronic circuit, and intrusion of rainwater, etc. may cause malfunction. If it gets wet, be sure to send it for repair.
- Do not leave this product within reach of small children.
< Battery Pack Care>
For safety and to extract maximum performance from the battery pack used,
observe the following points: Discharge and store the battery pack following
the battery instruction manual. Do not discharge a battery of more than 80%.
(Remaining capacity no less than 20%) Use the specified charger to charge the
battery pack.
< Battery Recycling>
A used battery is a valuable resource. Insulate the battery terminals and
dispose of the battery by taking it toa battery recycling center.
Specifications
(Specifications are subject to change without prior notice.)
- Input voltage XT60i connector: 5.0V-15V
- Input voltageXH 2.54 Balance port (15): MAX 15V (2-85): MAX 4,8V par cell
- oltage measurement accuracy: :0.005V @ 4.2V
- Balancing cells accuracy: <0.005V
- Support USB charging: QC 2.0/3.0, BC1.2, Maximum output12V / 2A
- Support battery: LiHv (1-85)/ LiPo (1-8S)/ LiFe(1-85) Lilon (1-85) / NiMH/Cd(3-105)
- Dimension: 80 X 55 X 19 mm
- Weight: 59g9
- Operating temperature: 0-40’C
- Operating humidity: 10%-90%RH (No condensation)
- Storage temperature: -20-60’C
- Storage humidity: 5%-90%RH (No condensation)
Nomenclature
Balance port
This product is suitable for the lithium battery, which has the XH 2.54 balance port, connect the balance port align from BAT- as shown in the figure. When connecting the 1S battery, the input Voltage from XT60i must be more than 5V.
System function screen
Connect the battery to the XT60i port or balance port of BR-4000 and press the menu button to display the following system function screen.
How to set system functions
The following is an explanation using the “Language” setting as an example
- Use the up button [ ]/ down button [ ] to select from the list, and press the menu button [ ] to confirm.
Function menu
Measurement display
< Battery connection>
When a battery is connected to the XT60i port
If you connect the battery to the XT60i port, only the total voltage is
displayed. To check the voltage of each cell, you need to connect the balance
connector of the battery to the balance port.
When a battery is connected to the balance port
When you connect the battery to the balance port, it displays the total
battery voltage, the maximum voltage difference between each cell, and the
voltage of each cell.
The icon displayed at the top of the left side of the screen differs depending on the port where the battery is inserted.
- You will see the following icons when you connect the XT60i port alone or both the XT60i port and the balanced port.
- If only the balance port is connected, the icon below will be displayed.
- If the battery is connected only to the balance port, you can start cell balancing by briefly pressing the menu button ( twice. (page.11)
- If the battery is connected to the XT60i port, you can start USB charging by briefly pressing the menu button [ twice. (page.13)
BEC power supply connection >
When you connect a BEC power supply to the XT60i port or balanced port, it
displays the BEC output voltage.
- Connect BEC power supply to XT60i port
- If you have an XT60i adapter, you can connect a BEC power supply to the XT60i port.
- The XT60i adapter is not available from Futaba.
Cell balance
If the battery is connected to the balance port, you can start cell balancing.
< Start of cell balance>
If the battery is connected only to the balance port, briefly press the menu
button [ twice to start cell balancing. Alternatively, select “Cell Balance”
from the “Function” menu, check the “Start” display, and press the menu button
( once. During the cell balancing operation, the left side of the screen turns
green, and the cell number being prepared on the right side of the screen is
displayed in orange.
When the “Power Save Mode” function is on, if no operation is detected during operation, the display will turn off, and the LED will start blinking green to signal that balancing is in operation.
If the battery is connected to the XT60i port, press the menu button [ once to display the system function screen. Use the down button [ ] to move to cell balance, and press the menu button [ once to start cell balancing.
- On the battery connection screen, Press the menu button [ once to display the system function screen.
- Press the down button [ ] to move to cell balance, and press the menu button [ once to start cell balancing
< End of cell balancee
When cell balancing is complete, the left side of the screen turns blue, and
an alarm sounds. This alarm sound will continue to sound at regular intervals
until the cell balance is stopped by the following operation. While the
display is off, the LED will start blinking blue to signal the end of
balancing.
< Stop cell balance>
Pressing the menu button [ twice brietly during or after cell balancing is in operation will stop cell balancing and return you to the battery connection screen.
After balancing is complete, stop immediately and be sure to remove the
battery.
If it is connected fora long time, it is very dangerous if it catches fire due
to over-discharge. Also, the battery will deteriorate.
USB Charge
Using the battery connected to the XT60i connector as a power source, you can chargea device (battery) that supports USB charging from the USB charging port .
Connect the battery to the XT60i port
< Start of USB charging>
Connect the battery to the XT60i connector, connect the battery to the USB
charging port with the charging cord, and device or battery press the menu
button [ ] twice to start USB charging. Alternatively, select “USB Charge”
from the “Function” menu, check the “Start” display, and press the menu button
[ ] once.
USB connection device (battery) information:
- :The device (battery) connected to the USB charging port supports Qualcomm QC 2.0/3.0
- :The device (battery) connected to USB charging port does not support Qualcomm QC 2.0/3.0
XT60i port input alarm voltage:
- If a NiNH or Pb battery is connected or the balance port is not connected, set it to the minimum operating voltage (5.0V) of BR-4000.
- When the balance port is connected Set to the single cell voltage set in “Low voltage alarm” in the system function menu.
- When the “Power Saving Mode” is on, the display turns off after 2 minutes of inactivity, and the LED starts blinking purple to indicate that USB charging is in operation.
USB charging will stop in the following cases.
- If the current exceeds 3A, USB charging will stop.
- USB charging will stop when the power exceeds 26W.
< Stop USB charging>
Usually, the device (battery) does not accept charging from the BR-4000 once
charging is complete, but the USB charging operation of the BR-4000 itself has
not stopped. To stop charging, use the following method.
Press the menu button [ ] twice briefly during or after USB charging is in operation to stop USB charging and return to the battery connection screen. Alternatively, select “USB Charge” from the “Function” menu, check the “Stop” display, and press the menu button [ once.
OAfter charging is complete, stop charging immediately and be sure to remove the battery from the XT60i port.
- If connected for a long time, it is very dangerous if it catches fire due to over-discharge. Also, the battery will deteriorate.
Receiver signal testing
If you connect the receiver’s channel connector or S.BUS connector to the balanced port of BR-4000 with the optional DSC cable for T7PX/ 10PX, you can check the RC control signal’s PWM and S.Bus signal.
< PWM>
You can check the RC control signal PWM of the system. The servo receiver
output signal is connected to the balance port, and the BR-4000 detects the
PWM output frame rate (cycle) and pulse width.
< S.BUS>
You can check the S.BUS signal. The S.BUS output signal is connected to the
balance port, and the BR- 4000 displays up to 18 channels of servo control
data, allowing you to check the signal position during F/S operation.
Futaba Service Center
2681 Wall Triana Hwy Huntsville, AL 35824, U.S.A.
- TEL 1-256-461-9399 or
- E-mail: contactus@futaba.com
FUTABA CORPORATION
Hobby Radio Control Business Center Sales & Marketing Department 1080
Yabutsuka, Chosei-mura, Chosei-gun, Chiba-ken, 299-4395, Japan TEL:
+81-475-32-6051, FAX: +81-475-32-2915 CFUTABA CORPORATION 2022, 9 (1)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>