Philio Smart Energy In Wall Meter PAB01-1 Manual
- June 8, 2024
- Philio
Table of Contents
- Philio
- Smart Energy In Wall Meter
- SKU: PAB01-1
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Technical Data
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Philio
Smart Energy In Wall Meter
SKU: PAB01-1
Quickstart
This is a ****
Energy Meter
for
CEPT (Europe).
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
1. Put your Z-Wave controller into inclusion mode by following the
instructions provided by the controller manufacturer. 2. Pressing Include
button three times within 2 seconds will enter inclusion mode.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
This dual meter module is a transceiver which is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. And it can act as repeaters within the network regardless of vendor to increase reliability of the network.Mini size design let the module can easily hide itself into the electricity distribution box and that will be good for the house decoration. This dual meter module is able to detect Instant power wattage (13800W/230Vac)(60 Amperes) of connected light or appliances.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.2. Within 1 second, press Include button again for 5 seconds. 3. IDs are excluded.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing Include button three times within 2 seconds will enter inclusion mode.
Exclusion
1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing Include button three times within 2 seconds will enter exclusion mode. 3. Node ID has been excluded.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 1| Z-Wave Plus LifelineFor group 1, the Switch will report (1) Instant
Power Consumption (Watt) read from CT1 (2) Accumulated Power Consumption (KWh)
read from CT1.
---|---|---
2| 1| For group 2, the Switch will report (1) Instant Power Consumption (Watt)
read from CT2 (2) Accumulated Power Consumption (KWh) read from CT2.
3| 1| For group 3, the Switch will report (1) The sum of instant Power
Consumption (Watt) read from CT1 and CT2 (2) The sum of accumulated Power
Consumption (KWh) read from CT1 and CT2.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Watt Meter Report Period
If the setting is configured for 1hour (set value =720), the PAB01 will
report its instant power consumption every 1 hour to the node of correspond
Group. The maximum interval to report its instant power consumption is 45
hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720
SettingDescription
1 – 32767 | 5*720s=3600s=1 hour |
---|
Parameter 2: KWH Meter Report Period
If the setting is configured for 1hour (set value =720), the PAB01 will
report its Accumulated Power Consumption (KW/h) every 1 hour to the node of
correspond Group. The maximum interval to report its Accumulated Power
Consumption (KW/h) is 45 hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720
SettingDescription
1 – 32767 | 5*720s=3600s=1 hour |
---|
Parameter 3: Selected Endpoint
_If Controller can’t use MultiChannel command class to access the endpoint
of PAB01, you may configure the endpoint value to react the Basic Command
Class Binary Switch Command Class or Meter Command Class V3.
Size: 1 Byte, Default Value: 3
SettingDescription
1 | 1CT1 |
---|---|
2 | 2CT2 |
3 | 3CT1 and CT2 |
Parameter 4: Threshold of Current for Load Caution
This is a warning when the current of load over the preset threshold value,
If the setting value is 6000, when the load wattage of CT1 or CT2 over 60A,
PAB01 will send current Meter Report command to the node of correspond Group.
Size: 2 Byte, Default Value: 6000
SettingDescription
10 – 6000 | 6000*0.01A=60A |
---|
Parameter 5: Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If
the setting value is 10000, when the Accumulated Power Consumption of CT1 or
CT2 over this value, PAB01 will send KWh Meter Report command to the node of
correspond Guoup, minum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000
SettingDescription
1 – 10000 | 10000*1KWH=10000KWH |
---|
Parameter 6: Existence of Endpoint3
Multi-Channel Command is a good way to control relay1 and relay2 of PAB01
individually. The endpoint3 of PAB01 is related to both relay1 and relay2. In
some condition it becomes redundant in Multi-Channel Command Class. When the
Existence of Endpoint3 is set as 2, the endpoint3 will be disabled. The
default value is 1. Endpoint1 and Endpoint2 are fixed, only Endpoint3 is
dynamic.
Size: 1 Byte, Default Value: 1
SettingDescription
1 | 1 : Endpoint3 exist |
---|---|
2 | 2 : No Endpoint3 |
Technical Data
Hardware Platform | SD3502 |
---|---|
Device Type | Whole Home Meter – Simple |
Network Operation | Always On Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16010004 |
Z-Wave Product Id | 0x013C.0x0006.0x001A |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>