SEADA SDC-TR01 Control Keyboard User Manual
- June 3, 2024
- SEADA
Table of Contents
SEADA SDC-TR01 Control Keyboard User Manual
Attentions
The descriptions in this manual may differ from the version you are using. If you are having trouble during using this manual, please contact our technical support for assistance. The contents of this manual will be updated, and our company reserves the right to leave it without notice.
Description
SDC-TR01 camera control keyboard is designed to work with all PTZ cameras via RS232/422/485 with PELCO-P, PELCO-D or VISCA protocols. Each unit of SDC-TR01 control keyboard incorporates an LCD display, making for professional video conferencing with control of maximumly 255 PTZ cameras.
This compact control keyboard is equipped with an ergonomic 4D joystick, allowing adjustment for PTZ camera movements. The intuitive keyboard-style buttons support precise and quick control over various features such as camera switch, focus, exposure and backlight compensation.
SDC-TR01 control keyboard can be widely used in video conferencing, distance learning/training, telemedicine and distance interview in schools, hospitals, workshops and so on.
Product Overview
Product Features
- Support RS422/485/232 control interfaces
- Support up to 255 cameras
- Support VISCA, PELCO-P, PELCO-D, protocol
- Support 4D joystick to control camera PTZ function
- Support controls of camera rotation, zoom, exposure, focus and so on
- Support displaying the real-time working status on its LCD display
- Support button sound prompt function
- Support recovery from short circuit on RS422 with its over-current protection ability
- Support up to 1200m communication distance on RS485 (0.5mm Twisted Pair Cable)
Technical Parameters
Communication Mode | Serial Port: RS422, RS232, RS485 |
---|---|
Communication Protocols | Serial Port: Visca, Pelco-D, Pelco-P |
Communication Baud Rate | 2400, 4800, 9600, 19200bps |
Interface Method | 5pin crimping terminal, RS232 interface |
Joystick | 4 Dimension (Control up, down, left, right, zoom, lockjoystick) |
Display Method | Blue screen LCD display |
Prompt Sound | Button sound prompt on/off |
Input voltage | DC12V |
Power Consumption | 6W MAX |
Operating TemperatureRange | -10°C-50°C |
Operating Humidity Range | 10%-90% |
Storage TemperatureRange | -20°C-70°C |
Storage Humidity Range | 10%~90% non-condensing |
Dimension | 320mm (L) x 180mm (W) x 107mm (H) |
Upgrade Method | RS232-USB upgrading |
Warranty | 2 years |
Precautions
- LCD Screen is fragile, do not squeeze or leave under harsh lighting for too long.
- The joystick rocker is fragile. Do use the original package or properly packaged if the item is damaged before shipping back.
- Keep the Control Keyboard in a temperature and humidity-controlled environment.
- Strictly follow the manual for correct connection
Accessories List
Name | Quantity | Unit |
---|---|---|
5PIN Plug | 1 | Pc |
DC-12V2A Power Adapter | 1 | Pc |
DB9F to MD6M Cable | 1 | Pc |
Download Card | 1 | Pc |
System Diagram
Keyboard Buttons Analysis
Button Functions
【ESC】Exit and back to former menu.
【SETUP】 Parameter settings button: Long press (3 seconds) to enter the
parameter setting status.
【CAM ON/OFF】Camera power on/off button.
【AF/MF】Auto focus / manual focus: Manual focus needs to work together with
[FOCUS]+ or [FOCUS-] button.
【SET PRESET】Preset settings button, working together with number keys and the
[ENTER] button.
【CALL PRESET】Call presets button, working with the number keys and the [ENTER]
button.
【AE/AAE】Auto Exposure / Aperture priority button, working together with
【OPEN】and
【CLOSE】 buttons
【BLC ON/OFF】: Back light compensation ON/OFF button.
【MENU ON/OFF】: MENU ON/OFF button.
【HOME】: HOME button.
【RESET】: Pan/tilt reset button.
【CLR】Clear button: clear the current inputs.
【0】~【9】Number keys: 0,1,2,3,4,5,6,7,8,9.
【ENTER】Confirmation key: Confirm the current inputs.
【NEAR】Focus in: manually focus in to make far distance objects
clearer.【FAR】Focus out: manually focus out to make near distance objects
clearer.
【TELE】Narrow-angle button/ Zoom-in button: increase lens magnification, reduce
the lens field of view, enlarge the monitor target.
【WIDE】Wide-angle button/Zoom out button: reduce lens magnification, expand
lens field of view and monitoring range.
【OPEN】Aperture plus button: Increase aperture manually. When the aperture is
at its maximum, the LCD screen text is displayed in full white. When the
camera menu mode is turned on, the next level menu is entered.
【CLOSE】Aperture minus button: Reduce manual aperture. When the aperture is at
its minimum, the LCD screen is displayed as black. When the camera menu mode
is turned on, the menu is returned to the previous menu.
【CAM】Address selection button: Select the address of the control device
(decoder or camera), it needs to use together with the number keys and [ENTER]
button.
【SET ID】Set ID button: long press 3s to set the cascade camera protocol
address.
LCD screen display
All button operations will be displayed on LCD screen. It would enter power saving mode (with darkest light), with initialising status displayed if no operation for 30 seconds
Joystick Control
Back Panel Interfaces
Back Panel Details: 1x 5PIN crimping terminal interface, 1 x RS232 interface, 1xDC-12V power socket, 3 x indicator lights as picture below:
Functional number description
Number | Label | Physical interface | Description |
---|---|---|---|
**** ① | **** RS-422 | **** Control output (Ta, Tb, Ra, Rb) | 1. To |
connect RS485 bus: (Ta) to connect RS485+, (Tb) to connect RS485-; 2. to
connect RS422 Bus: (Ta) to connect RXD IN-, (Tb) to connect RXD IN+, (Ra)
toconnect TXD IN-, (Rb) to connect TXD IN+
②| Ground| Control line to ground (G)| Signal control line to ground.
③| PW| Power indicator| The light will always be red when keyboard is working.
④| TXD| Sending data indicator| The light will flicker in green when
sending data
**** ⑤| RXD| Receiving data indicator| The light will flicker in green when
receiving data.
⑥| DC-12V| Power input| DC12V power input
Parameter Setting and Query
PTZ Setup
E.g., With address 28, steps for Pelco-P protocol and baud rate 9600 are as follows: Press 【SETUP】 button for 3 seconds under normal working mode, it displays as follows:
Then press 【ENTER】, there will be a 1sec beep sound when setting done.
Press【ESC】 3 times to back to normal working mode.
Note: Steps to set all devices to be with same protocol and baud rate are
as follows:
Enter the setup page and choose the corresponding protocol and baud rate. All devices within 0-255 addresses will be set with the same protocol and baud rate.
System Setup
System setup includes password setting, restore factory setting, Indicate sound switch setting, Keyboard ID and Keyboard lock switch setting. Here shows the steps to restore factory setting and set keyboard lock switch.
Password Setting
Press 【SETUP】 button for 3 seconds under working mode, it displays as follows:
Then input the new password again, press 【ENTER】, there will be a 1sec beep sound when setting done.
Press【ESC】twice to back to normal working mode.
Restore Factory Setting
Press 【SETUP】 button for 3 seconds under working mode, it displays as follows:
Press 【ENTER】, there will be a 1sec beep sound when setting done.
Press 【ESC】 twice to back to normal working mode.
Keyboard Parameter Setting Frame
PTZ Setup| Camera address: XXX (to be set)| PROTPCOL| PELCO-D, PELCO-P,RULE, etc.
---|---|---|---
Baud Rate| 2400, 4800, 9600,19200
Camera address:0-255 (all set the same)| Same as above
SYSTEM Setup| **** >SET PASSWORD| OLD PW: old password| 4 digits
NEW PW (new password)| 4 digits
AGAIN PW: (confirm password)| 4 digits
LOAD DEFAU(Restore factory setting)| ** confirm?| Press 【ENTER】to confirm, and【ESC】to exit.
SYSTEM Setup| >SOUND SETUP(button sound switch setting)| ON| Move joystick right/left and press【ENTER】to confirm
OFF
HOST ID SET| Keyboard address| Number 【 0 】 – 【 15 】**
LEARN SETUP(keyboard lock setting)| ON| Move joystick right/left and press【ENTER】to confirm to set password
OFF
Keyboard Parameter Query
Protocol: X Baud rate: X | current control protocol and baud rate. |
---|---|
Camera query | Camera protocol: 001 |
Baud rate | Corresponding baud rate |
System query | Model number: XXXXXXXX |
Serial number: XXXXXXXX | 8 digits serial number on camera |
Device number: XX | 2 digits keyboard ID number |
Keyboard lock (ON/OFF) | Display the current setting of the keyboard lock |
--- | --- |
Sound (ON/OFF) | Display the setting of the current button sound prompts |
Typical wiring diagram
Typical wiring diagram
Connection with surveillance dome camera
Connection with video conference camera
- Control output: connect camera RS485+ with keyboard Ta, RS485- with Tb.
- Deputy control device: either RS485 output from DVR or keyboard is available
Connection Analysis
Connection between keyboard and camera
With RS422 bus connection way, the keyboard third pin (Ra) is connected with the camera third pin TXD IN-, the keyboard fourth pin (Rb) with the camera fourth pin TXD IN+, the keyboard first pin (Ta) with the camera first pin RXD IN-, the keyboard second pin (Tb) with the camera second pin RXD IN
Keyboard/CAMERA
- Ra: TXD INRb: TXD IN+
- Ta: RXD INTb: RXD IN+
With RS232 connection way, the keyboard (10pin connecting terminal) first pin RXD is connected with the third pin TXD of camera RS232 port, the keyboard second pin TXD with the camera fifth RXD, the keyboard third GND with the camera forth pin GND. (It is also available to connect camera with the standard RS232 port on the keyboard.)
Keyboard/CAMERA
- RXD: TXD
- TXD: RXD
- GND: RXD
The camera can be controlled by any connection way mentioned above.
Connection between cameras
With the RS422 bus cascade connection, the output of camera 1 is connected with the input of camera 2, and the output of camera 2 is connected with the input of camera 3, and so on so forth. As shown below:
The RS232 cascade connection way is almost the same as that of RS422. The output of camera 1 is connected with the input of camera 2, the output of camera 2 is connected with the input of camera 3, and so on so forth.
Appendix
RS485 bus introduction:
RS485 bus, RS is the abbreviation of English “recommended standard”, 485 is the identification number. The RS485 serial bus is widely used in applications where the communication distance ranges between dozens of meters to 1km more. RS485 uses balanced transmitting and split receiving, so it can reject common mode interference. In addition to the high sensitivity of the bus transceiver, it can detect voltages as low as 200mV, so the transmitted signal can be recovered beyond the kilometres away. As RS485 adopts half-duplex working mode, and only one point is allowed to be under sending status any time, the transmitting circuit must be controlled by the enable signal. RS485 is very convenient for multi-point interconnection, which help save many signal lines. RS485 can be used to make a distributed system, which allows up to 128 drivers and 128 receivers to be connected in parallel, depending on the chip used by the driver and receiver, and the bus drive capability is limited by the weakest one. However, in practical applications we can extend it with the RS485 distributor
Transmission distance
When a 0.56mm (24AWG) twisted pair cable is used as the communication cable, the theoretical value pf the maximum transmission distance varies with different baud rate: 1800 meters can be transmitted when the baud rate is 2400 bps, and 600 meters under 19200 bps. When using a thinner communication cable or using the product in an environment with strong electromagnetic interference, or when too many devices are connected with the bus, the maximum transmission distance will be shortened accordingly, or the maximum distance is longer.
Connection method and terminating resistor
The RS485 industrial bus standard requires daisy chain connection between devices. The two ends must be connected with a 120Ω termination resistor. The two balance distances must be within 7m.
Problems in Actual Application
The star link mode will always be used in actual constructions, requiring the terminating resistor to be linked with the two devices in the farthest distance. But it does not meet the RS485 industry standards. When the distance between each device is too short, signal reflection and anti-interference ability reducing would frequently happen, which will decrease the reliability of the control signal. It means the camera will not be under control or under control intermittently. In this case, the application of RS485 distributor is recommended, which can effectively convert the star link mode to one qualified by the RS485 industry standards. It will help avoid problems and improve the communication reliability.
Troubleshooting
Troubles | Analysis | Solutions |
---|---|---|
PTZ S surveillance Camera cannot be controlled by SDC-TR01 | 1.check RS485 | |
cable | Step 1: Whether the RS485 A and B are reversed, Step 2: check |
whether the RS485 line is short-circuited when power off.
2.check the correspondence of camera protocol and baud rate settings with
those ofSDC-TR01| Step 1: Check whether the current protocol and baud rate are
correspondent. Step 2: Restore the SDC-TR01default settingsand then reset it.
3.Check whether the PTZ indicator light flickering when control.| Step 1: If
the PTZ indicator light flickers when control, then there is no problem with
SDC-TR01.Step 2: If the PTZ indicator light does not flash when control, there
is some problem with the RS485 output of the keyboard .Please return to
factory for repairing.
Video conference camera cannot be controlled by SDC-TR01| 1.check the control
cable| Make sure a right connection of the control cable.
2.check the correspondence of camera protocol and baud rate settings with
those ofSDC-TR01| Check whether the current protocol and baud rate of each
address are correspondent. Please refer to camera user manual.
Not all cameras can be controlled by SDC-TR01.| 1. Inspect accessories.|
Inspect all connection cables.
**** 2.Check settings.| Check whether the current protocol and baud rate of
each address are correspondent.
| 3.Probably a problem with star wiring.| Step 1: At the farthest end of
RS485, connect an impedance of 120Ω.Step 2: Add RS485 distributor to the star
connection
---|---|---
Some cameras rotate at the same time when control.| 1.Inspect camera address
setting.| Check if the address codes of the cameras that are moving together
are the same, please stagger the address code settings. (Note: you need to
restart after modifying the dialing switch to take effect)
Forget the locking password| Long press the [SETUP] key to enter the system
settings and reset the password, if happened at any time.
Button silent| Enter the system settings and turn on the button sound.
Copyright Statement
All the contents in this manual and its copyright are owned by the company. No one is allowed to imitate, copy, or translate this manual without the company’s permission. This manual contains no guarantee, standpoint expression or other implies in any form. Product specification and information in this manual is for reference only and subject to change without notice. All rights reserved. No reproducing is allowed without acknowledgement.
Website: www.seada.co.uk
Email: sales@seada.co.uk
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>