AcuityBrands WL1 Watch Light LED NEMA Security Light User Manual
- June 9, 2024
- AcuityBrands
Table of Contents
LED IMPORTANT SAFETY INSTRUCTIONS
WL1 Watch Light LED NEMA Security Light
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
√ Disconnect or turn off power before installation or servicing.
√ Verify that supply voltage is correct by comparing it with the luminaire
label information.
√ Make all electrical and grounded connections in accordance with the National
Electrical Code (NEC) and any applicable local code requirements.
√ All wiring connections should be capped with UL approved recognized wire
connectors.
CAUTION
RISK OF INJURY
√ Wear gloves and safety glasses at all times when removing luminaire from
carton, installing, servicing or performing maintenance.
√ Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF BURN
√ Allow lamp/fixture to cool before handling.
Do not touch enclosure or light source.
√ Do not exceed maximum wattage marked on luminaire label.
√ Follow all manufacturer’s warnings, recommendations and restrictions for:
driver type, burning position, mounting locations/methods, replacement and
recycling.
CAUTION
RISK OF FIRE
√ Keep combustible and other materials that can burn, away from lamp/lens.
√ Do not operate in close proximity to persons, combustible materials or
substances affected by heat or drying.
LED IMPORTANT SAFETY INSTRUCTIONS
CAUTION: RISK OF PRODUCT DAMAGE
√ Never connect components under load.
√ Do not mount or support these fixtures in a manner that can cut the outer
jacket or damage wire insulation.
√ Unless individual product specifications deem otherwise: Never connect an
LED product directly to a dimmer packs, occupancy sensors, timing devices, or
other related control devices. LED fixtures must be powered directly off a
switched circuit.
√ Unless individual product specifications deem otherwise: Do not restrict
fixture ventilation. Allow for some volume of airspace around fixture. Avoid
covering LED fixtures with insulation, foam, or other material that will
prevent convection or conduction cooling.
√ Unless individual product specifications deem otherwise: Do not exceed
fixtures maximum ambient temperature.
√ Only use fixture in its intended location.
√ LED products are Polarity Sensitive. Ensure proper Polarity before
installation.
√ Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal
grounding equipment must be worn during all installation or servicing of the
unit.
√ Do not touch individual electrical components as this can cause ESD, shorten
lamp life, or alter performance.
√ Some components inside the fixture may not be serviceable. In the unlikely
event your unit may require service, stop using the unit immediately and
contact an ABL representative for assistance.
√ Always read the fixtures complete installation instructions prior to
installation for any additional fixture specific warnings.
Please see product specific installation instructions for additional warnings
or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For
a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
Our Brands| Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC| Indoor Lighting
Gotham
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting| Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen
Controls| DARK TO LIGHT
Lighting Control & Design
ROAM
Sensor Switch
Synergy
---|---|---|---|---
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out
of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2013 Acuity Brands Lighting, Inc. All rights reserved. 6/12/13
INTRODUCTION
Product Description
The WatchLight Series luminaire has been listed to applicable U.S. & Canadian
safety standards CSA (optional). They are suitable for use in wet locations
and maximum ambient temperatures to 40°C depending on luminaire configuration.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Storage
The luminaire should not be stored outside with the glass facing up.
INSTALLATION
Tools and Materials Required
Description
Flat Head Screwdriver
Torque Wrench (ft.-lbs.)
2 Philips Head Screwdriver
Use
Mounting / Leveling:
Determine the size of the mast arm. This luminaire is designed to accommodate
a mast arm from 1-1/4” to 2” diameter. The luminaire is factory set to mount
to the 11/4” arm. To mount to a 2” arm, the following modificationis
required.
The V-shaped bracket must be flipped. Remove the fitter bolts and flip the
bracket to mount to a 2” arm.
Standard Mounting:
Loosen (DO NOT REMOVE) the fitter bolts. Lift the luminaire into position in
front of the mast arm such that the mast arm enters through the opening at the
rear of the luminaire housing. The luminaire should be mounted with the glass
facing down. The luminaire should never be mounted with the glass facing up.
The luminaire illumination tilt angle may be adjusted by the adjustment steps
located in the rear of the housing. Recommended fitter bolt torque: 10-12 FT-
LBS
CAUTION
OVER-TORQUING OF FITTER CLAMP BOLTS CAN CREATE CRACKS IN THE HOUSING CAUSING
THE FIXTURE TO FALL TO THE GROUND.
WIRING: Feed the supply wires through the mast arm, dress them so they do
not interfere with any components and so they will not be pinched in the door
and connect them to the proper terminals on the terminal block or free leads.
Some luminaires also include an optional terminal block cover which will need
to be lifted. Verify the supply voltage is correct as noted on the nameplate
label. If included, push the terminal block cover back in place to keep
terminals covered.
Terminal Block:
Recommended terminal block screw torque: 15 IN-LBS
Optional Photocontrol:
Plug the photocontrol into the receptacle ensuring gasket is firmly seated. Twist clockwise until it locks into position. If Photocontrol Receptacle rotation is required, loosen the two receptacle screws, but do not remove. Rotate the center of the receptacle, then re-tighten screws until snug, using 12-15 IN-LBS of torque. Failure to meet specified torque can result in water ingress.
Warranty:
Five-year limited warranty. Full warranty terms located at http://www.acuitybrands.com/customerresources/terms_and_conditions.aspx
©2014 Acuity Lighting Group, Inc.
REV E IM-426
IM426C
Documents / Resources
|
AcuityBrands WL1 Watch Light LED NEMA Security
Light
[pdf] User Manual
WL1 Watch Light LED NEMA Security Light, WL1, Watch Light LED NEMA Security
Light, NEMA Security Light, Security Light
---|---
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>