ELAN EL-IPD-AMP-2CH 2 Channel Audio Amplifier
FCC and IC Information
This Class B digital apparatus complies with Part 15 of the FCC rules and with
Canadian ICES-003.
Operation is subject to the follwing conditions:
- This device may not cause interference and
- This device must accept any interference, including interference that may cause undesired operation of the device.
Energy Efficiency – Commission Regulation (EC) no 1275/2008
POWER CONSUMPTION:
- Off Mode: 0W
- Standby Mode: ≤ 0.5W – The device will automatically enter standby mode after approximately 30 minutes of no signal or no user input.
Important Safety Instructions
-
Read these instructions.
-
Keep these instructions.
-
Heed all warnings.
-
Follow all instructions.
-
Do not use this apparatus near water.
-
Clean only with a dry cloth.
-
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
-
Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.
-
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
-
Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles and the point where they exit from the apparatus.
-
Only use attachments/ accessories specified by the manufacturer.
-
Use only with the cart, stand, tripod, bracket or table specified by the manufacturer or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
-
Unplug this apparatus during lightning storms or when unused for long periods of time.
-
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
-
Do not expose this apparatus to dripping or splashing and ensure that no objects filled
with liquids, such as vases, are placed on the apparatus. -
To completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle.
-
The power supply cord (sometimes referred to as the “Mains Plug”) is used as the disconnect device and shall remain accessible and operable at all times.
-
Do not expose batteries to excessive heat such as sunshine, fire or the like.
-
Open flame sources, such as lighted candles, should NOT be placed on the apparatus.
-
Protective earthing terminal. The apparatus should be connected to a mains socket outlet with a protective earthing connection.
WARNING: To reduce the risk of fire or electric shock, do not expose this
apparatus to rain or moisture.
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the product.
FCC Required Text
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate, radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Overview
The EL-IPD-AMP-2CH 2 Channel Audio Amplifier is designed to be used in a stand-alone configuration or with other amplifiers and pre-amps within the ELAN® IP audio distribution family of products using Dante® Audio Networking. ELAN IP enabled audio distribution simplifies whole house audio distribution and enhances the intelligent home by delivering high quality audio over an existing network. Easily scaling from a single chassis solution to a decentralized multi-chassis / multi-source implementation, ELAN IP audio distribution meets the needs for projects of any size.
What’s Included
- EL-IPD-AMP-2CH 2 Channel Audio Amplifier
- Power Cord
- Mounting Brackets
Functions and Indicators
FRONT VIEW
1 | Amplifier Status |
---|---|
2 | Power |
Condition | Amplifier Status |
--- | --- |
Power On, Booting | Off |
Power On, Connected to Network | Off |
Self-Check Failure | Off |
Boot Failure | Solid Red |
No Network Found | Off |
Power Off | Off |
Chassis in Low Power Mode | Solid Blue |
Chassis in Sleep Mode | Off |
Amplifier or Preamplifier Channel Clipping | Solid Amber |
Amplifier Channel in Protection Mode | Solid Red |
Chassis Identify Mode | Flashing Amber |
REAR VIEW
| Item| Description
---|---|---
1|
Power
|
AC 100-120 / 220-240 V~ 50/60Hz, 200W
2
|
Network Reset
|
Using a paper clip, with power on press and hold for 10 seconds to reset to DHCP
3
|
Network
• 1 RJ45 Jack
|
100/1000 Ethernet DHCP Enabled by Default
4
| Digital Audio Inputs
• 1 Optical TOSLINK Input
• 1 Coaxial RCA Input
|
Stereo, PCM, 96kHz, 24-bit
5
| Line Level Audio Inputs
• Stereo Analog RCA
| Max input level 2.0 VRMS
Input Sensitivity: 0dbV (1.0 VRMS)
Input Impedance: 47k Ω-49k Ω
6| Subwoofer Output
• RCA
| Variable, follows main volume setting of the amplifier.
Impedance: 470 Ω
7
|
Amplifier Output
• 2 Stereo Amplifier Outputs
• Bridgeable
| Output Power: 80W at 8Ω
100W at 4Ω
200 W in Bridge mode
THD: < 0.05% @ 1kHz
Frequency Response: 20Hz to 20kHz, +.5dB/-.5dB
Crosstalk: >60dB @ 1kHz/1W
Signal to Noise: >90dB
Lip Sync Delay
• Individual Lip Sync Delay for Each Speaker Zone
|
Delay Time: 0 – 400ms Adjustable: 10ms increments
Tone Control
• Individual Tone Control for Each Zone
| Five-band equalizer Loudness on/off
Temperature
| Operating Temperature: +5° C – +45° C (+41°F – +113°F) Operating Humidity: 0
– 90% non-condensing
Storage Temperature: 0° C – +60° C (32°F – +140°F)
Dimensions| 7.00D X 7.91W X 1.97H in. / 178D X 201W X 50H mm
Weight| 4.10 lbs / 1.86 Kg
Applications
The following applications are examples of how the EL-IPD-AMP-2CH 2 Channel
Audio Amplifier Matrix can be used. For more detailed system design
guidelines, see the Design Guide for the ELAN IP Amplifier from
www.elancontrolsystems.com.
Combining the EL-IPD-AMP-2CH 2 Channel Audio Amplifier with the EL-IPD-MTX-8CH
Multi Zone Audio Matrix with the optional EL-IPD-NAC-EXT Network Audio Card
adds an additional audio zone. Multiple EL-IPD-AMP-2CH 2 Channel Audio
Amplifiers can be added to a system as more remote audio zones are needed.
NOTE: The amplifier is limited to one input device at a time. The input
(Analog, Coax, or Optical) is selected using ELAN Configurator during
installation.
Single Chassis
Zone Extender
Installation
Mount the EL-IPD-AMP-2CH 2 Channel Audio Amplifier in a cabinet by setting it on a sturdy shelf. As with any electronic device the EL-IPD-AMP-2CH generates heat at all times, but considerably more when in use. Ensure clear positive airflow within the cabinet by using fans. Locating the EL-IPD-AMP-2CH in a completely enclosed cabinet is not recommended due to heat build up. Use the included mounting brackets to secure to a wall or other surface if needed .
POWER
The amplifier includes an internal switch mode power supply for use in AC
100-120 / 220-240 V environments.
NETWORK
Connect the amplifier to the LAN for control and audio routing (if used in a
Dante configuration). Please review the ELAN IP Amp Design Guide for proper
network setup depending on how the amplifier is being used.
AUDIO INPUTS
Two 2 channel PCM digital inputs (1 optical and 1 coax stereo) 2, and one line
level analog stereo pair audio inputs are available. When used with other
Dante-enabled ELAN amplifiers, the input device is available as an independent
source available to any zone in the system.
NOTE: The amplifier is limited to one input device at a time. The input
(Analog, Coax, or Optical) is selected using ELAN Configurator during
installation. Subwoofer Out Connect a powered subwoofer.
SPEAKER OUTPUTS
CAUTION! ALL SPEAKER WIRE CONNECTIONS MUST BE MADE WITH THE CHASSIS POWER OFF
When connecting more than one speaker to a set of terminals, be sure to
calculate the impedance values and not exceed the rating for the amplifier.
Connect 4ohm or 8ohm speakers – The amplifier outputs’ default is 4ohms. If
connecting 8ohm speakers, the setting must be changed during system
configuration. For more detail, see the Design Guide for the ELAN IP
Amplifier.
CONFIGURATION
For detailed configuration information, download the Design Guide for the ELAN
IP Amplifier from www.elanhomesystems.com.
Network Setup FAQs for Dante
What type of Ethernet cable is recommended for Dante?
Cat5e or Cat6 cable is recommended. For purely 100Mbps networks, CAT5 may be
used.
Does Dante work with Fiber Optic network cable?
Yes. Because Dante works with standards based networking technology, using
fiber is simple. Use a switch that supports fiber connections to send Dante
data over a fiber optic cable.
Can Dante operate over a Wi-Fi network?
No. While possible in principle, the practical limitations of current wireless
technology (802.11a/b/g/n) render reliable performance unachievable.
Does Dante require any special network infrastructure?/
No, special network infrastructure is not required. Since Dante is based upon
universally accepted networking standards, Dante-enabled devices can be
connected using off-the-shelf Ethernet switches and cabling.
Does Dante require a dedicated network infrastructure?
No, a dedicated network infrastructure is not required. Dante-enabled devices
can happily coexist with other equipment making use of the network.
Does Dante require special switches?
No. But we strongly recommend that Gigabit switches be used due to the clear
advantages in performance and scalability. If using a 100Mbps, see the design
guide and and integration note for ELAN products.
Limited Warranty
Nortek Security & Control ( ‘NSC’ ) warrants the E L-IPD-AMP-2CH to be free
from defects in materials and workmanship for
the period of two years (2 years) from the date of purchase. If within the
applicable warranty period above purchaser discovers that such item was not as
warranted above and promptly notifies ‘NSC’ in writing, ‘NSC’ shall repair or
replace the item at the company’s option. This warranty shall not apply (a) to
equipment not manufactured by ‘NSC’, (b) to equipment which shall have been
installed by other than an ‘NSC’ authorized installer, (c) to installed
equipment which is not installed to ‘NSC’s’ specifications, (d) to equipment
which shall have been repaired or altered by others than ‘NSC’, (e) to
equipment which shall have been subjected to negligence, accident, or damage
by circumstances beyond ‘NSC’s’ control, including, but not limited to,
lightning, flood, electrical surge, tornado, earthquake, or other catastrophic
events beyond
‘NSC’s’ control, or to improper operation, maintenance or storage, or to other
than normal use of service. With respect to equipment sold by, but not
manufactured by ‘NSC’, the warranty obligations of ‘NSC’ shall in all respects
conform to the warranty actually extended to ‘NSC’ by its supplier. The
foregoing warranties do not cover reimbursement for labor, transportation,
removal, installation or other expenses which may be incurred in connection
with repair or replacement. Except as may be expressly provided and authorized
in writing by ‘NSC’, ‘NSC’ shall not be subject to any other obligations or
liabilities whatsoever with respect to equipment manufactured by ‘NSC’ or
services rendered by ‘NSC’.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESSED AND
IMPLIED WARRANTIES
EXCEPT WARRANTIES OF TITLE, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF
MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.
ATTENTION: To our valued Customers
To ensure that customers obtain quality pre-sale and after-sale support and
service, Nortek Security & Control products are sold exclusively through
authorized dealers. Nortek Security & Control products are not sold online.
The warranties on Nortek Security & Control products are NOT VALID if the
products have been purchased from an unauthorized dealer or an online
E-tailer. To determine if your Nortek Security & Control reseller is
authorized, please call Nortek Security & Control at
800-622-3526.
main:
1 800-472-5555 – US
1 707-283-5900 – International 1
707-283-5901 – Fax
tech support:
techsupport@elancontrolsystems.com
web:
elancontrolsystems.com
©2022 Nortek Security & Control LLC. ELAN® is a registered trademark of Nortek
Security & Control, LLC. Other brand names and products names mentioned herein
may be the trademarks, tradenames, services marks or registered trademarks of
their respective owners. All rights reserved.
References
- ELAN is now Nice - Nice North America
- ELAN is now Nice - Nice North America
- ELAN is now Nice - Nice North America
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>