ELAN EL-SC-300 System Controller Installation Guide
- June 6, 2024
- ELAN
Table of Contents
- ELAN EL-SC-300 System Controller
- IMPORTANT SAFETY INSTRUCTIONS
- FCC and IC Information:
- Included in the box
- Front Panel
- Rear Panel Connections
- Mounting
- RS-232 Serial Connections
- RS-485 Serial Connections
- IR Output Connections
- Signal Input Connections
- Relay Connections
- LAN / PoE Connection
- Reset Button
- Power
- LED Status Indicator
- Network Connection
- Specifications
- Limited Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ELAN EL-SC-300 System Controller
IMPORTANT SAFETY INSTRUCTIONS
- Read, understand and follow ALL safety and installation instructions included in this manual. Failure to follow the included documentation may damage the product and will void the manufacturer’s warranty.
- Follow ALL installation guidelines included with the product. Installation of the product in high humidity environments, in close proximity to heat sources and /or non-recommended locations, will impede, interfere and/or damage the intended operation of the product.
- Only use attachments and accessories which have been specified for use by the manufacturer.
- The use of abrasive, liquid or solvent-based cleaning fluids will damage the product. Please refer and follow all Product Care instructions included with the product.
- Product Servicing may only be completed by authorized or certified service centers & personnel. For a complete list of product servicing options, please follow the instructions included in the product documentation and /or contact the original manufacturer for details.
FCC and IC Information:
This Class B digital apparatus complies with Part 15 of the FCC rules and with
Canadian ICES-003 and RSS-247.
RESTRICTIONS IN THE 5 GHZ BAND: Within the 5.15 to 5.25 GHz band, UNII devices
will be restricted to indoor operations.
Operation is subject to the following two conditions:
- This device may not cause interference and
- This device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil numérique de classe B est conforme aux normes canadiennes ICES-003 et RSS-247. RESTRICTIONS DANS LA BANDE DE 5 GHZ: Dans la bande de 5,15 à 5,25 GHz, les appareils UNII seront restreints aux opérations. Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d’interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement.
Warning:
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
FCC and IC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment and meets the exemption from the routine evaluation
limits in section 2.5 of RSS 102.
- This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
- This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters from users and bystanders.
Warning:
The device meets the exemption from the routine evaluation limits in section
2.5 of RSS 102, and users can obtain Canadian information on RF exposure and
compliance from the Canadian Representative Nortek Control at Tel:
604-765-6933.
To maintain compliance, only the antenna types that have been tested shall be
used. This radio transmitter [IC: 1078A-00211] has been approved by
Innovation, Science and Economic Development Canada to operate with the
antenna types listed below, with the maximum permissible gain indicated.
Antenna types not included in this list that have a gain greater than the
maximum gain indicated for any type listed are strictly prohibited for use
with this device.
Wave Developer’s Kit:
This product can be operated in any Z-Wave™ network with other Z-Wave
certified devices from other manufacturers. All mains operated nodes within
the network will act as repeaters of vendors to increase the reliability of
the network.
In an Elan SC Series System Controller, the host application controls the
device reset feature. If this controller is the primary controller for your
network, resetting it will result in the nodes in your network being orphaned
and it will be necessary after the reset to exclude or re-include all of the
nodes in the network. If this controller is being used as a secondary
controller in the network, use this procedure to reset the controller only in
the event that the network primary controller is missing or otherwise
inoperable.
The ELAN Training Guide contains valuable hardware and software reference documentation and is considered an important supplement to this document. Make sure you have the latest version by visiting the ELAN Dealer website at www.elancontrolsystems.com and following the Dealer Resources link.
Included in the box
- (1) EL-SC-300 System Controller
- (2) Rack Mount Brackets
- (1) 12V DC Power Supply
- (7) Male DB9 to female RJ45 adapter
- (3) Female DB9 to female RJ45 adapter
- (10) Phoenix-style male connectors, (4) black for signal inputs, (6) green for relays
- (1) Wi-Fi Antenna
Front Panel
Rear Panel Connections
Mounting
The EL-SC-300 System Controller is designed to mount on a shelf or hang in a cabinet or rack.
Shelf Mounting
The EL-SC-300 has feet to protect finished surfaces. Set the controller in a
location that will allow you to properly manage connected wiring so that
tension is not placed on the connections. Wire tension will cause the unit to
move and may cause wires to become disconnected. Dimensions with feet: 17” W x
2.25” H x 14” D (431.8mm W x 57.2mm H x 355.6mm D)
Rack Mounting
The Rack Mount Brackets included with the EL-SC-300 attach to the chassis
using the included screws. Do not use longer screws to attach the brackets as
this may permanently damage the unit. Remove the feet from the EL-SC-300
before rack mounting the unit. When mounting in very warm locations (i.e.
enclosed rack or cabinet) leave a rack space above and/or below the unit for
ventilation. Dimensions without feet, with rack-mount brackets: 19” W x 1.75”
H x 14” D (482.6mm W x 44.45mm H x 355.6mm D)
RS-232 Serial Connections
Connect up to eight RS-232 serial controlled devices using an included DB9 to RJ45 adapter to the RS-232 port on the rear of the controller. For null modem connections, the ports can be configured in ELAN Configurator. Wiring pin-out for the RJ45 connector.
RS-232 Port Pin #
1
| 586A Color Code
White / Green
| 586B Color Code
White / Orange
| Function
N/C
---|---|---|---
2| Green| Orange| DCD
3| White / Orange| White / Green| DTR
4| Blue| Blue| GND
5| White / Blue| White / Blue| RXD (receive)
6| Orange| Green| TXD (transmit)
7| White / Brown| White / Brown| CTS
8| Brown| Brown| RTS
RS-232 Connections
The table shows the 568A and 568B color codes and the function of each
conductor of the RS-232 ports. Please refer to the ELAN Integration Note for
the specific device to determine the proper RJ45 to DB9 adapter to use.
CAUTION: Do not connect cables with PoE power on them to the RS-232 or
RS-485 ports as it will damage the unit.
RS-485 Serial Connections
The two RS-485 ports allow connection to Full-Duplex (Aprilaire thermostats,
for example) and Half-Duplex (Pentair Pool and Spa controllers, for example)
RS-485 controlled devices without using adapters. The table below shows the
T-568A and T-568B color codes and the function of each conductor of the RS-485
ports. Please refer to the Integration Notes for the device you are
integrating for wiring and programming specifics.
CAUTION: Do not connect cables with PoE power on them to the RS-232 or
RS-485 ports as it will damage the unit.
RS-485 Port Pin #| 586A Color Code| 586B Color Code|
Naming Conventions
---|---|---|---
1| White / Green| White / Orange| RxD +| RD (B)| B+
2| Green| Orange| RxD –| RD (A)| B-
3| White / Orange| White / Green| TxD +| TD (B)| A+
4| Blue| Blue| N/C| |
5| White / Blue| White / Blue| N/C| |
6| Orange| Green| TxD –| TD (A)| A-
7| White / Brown| White / Brown| GND| GND| GND
8| Brown| Brown| N/C| |
IR Output Connections
Twelve discrete IR outputs are supplied to control third-party devices. Each output is compatible with Xantech single and dual emitters. IR outputs are 12V.
Signal Input Connections
Four signal input ports provide a way to trigger events based on a contact
closure or voltage input. Detects 5V to 24V DC / 24VAC Max. For example, use a
contact closure on driveway sensors to trigger lights or push messages. Or use
the voltage detector to sense when a standard doorbell chime is rung to
trigger an ELAN doorbell chime through an audio system.
NOTE: DO NOT WIRE DIRECTLY TO THE DOORBELL BUTTON, THIS WILL DAMAGE THE
EL-SC-300. For detailed wiring instructions, please refer to the Integration
Note.
Please verify your device can accept 12V input for contact closure, as this could cause damage to the device if not rated for 12V.
Relay Connections
Six normally open relays are available for controlling third-party devices –
motorized lifts, window shades, and projection screens. The included removable
connectors will accept up to 16ga bare copper leads. Be careful to verify that
no portion of one wire touches the other wire. Prior to connection verify that
the connected load does not exceed 24volts AC/DC or 1amp. If either parameter
is exceeded, add a higher capacity relay to control the load and use the EL-
SC-300 output to control that relay.
NOTE: The relays only control turning the external load on / off and do
not supply any power. For detailed wiring instructions, please refer to the
Integration Note and documentation for the connected device.
LAN / PoE Connection
The EL-SC-300 can be powered over Ethernet (PoE). The minimum PoE requirement
is IEEE 802.3at. 42.5 – 57 VDC, 600 mA maximum.
NOTE: The EL-SC-300 can be connected via WiFi, however, a wired
connection is preferred.
Reset Button
Located on the right rear of the controller is the recessed pinhole button that can be used in three ways:
- 2-second press and release resets the controller to DHCP
- 20-second press and release remove all configuration information. The software version will be maintained.
- While applying power, a 10-second press and release will perform a full factory reset. The software will revert to factory default version. DO NOT remove power during a factory reset as it will permanently damage the unit. Allow the unit to reboot and become discoverable (about 4 minutes). Note: the LED will remain red during the reset process.
WARNING! THESE ACTIONS CAN NOT BE UNDONE!
Power
Once all other connections have been completed, connect an Ethernet cable connected to a PoE switch or the 12 VDC, 2.5A power supply to the DC input.
LED Status Indicator
The LED communicates the status of the controller:
-
Blue
Power on / connected to the network -
Blue flashing slowly
Boot up -
Blue flashing rapidly
Controller updating -
Amber
Power on / not connected to the network -
Red
Boot failure -
Red flashing
Self-check failure
Network Connection
The EL-SC-300 is factory set to use DHCP. First, connect to a wired network. Once connected, use Configurator to set a static IP address or connect via WiFi.
Specifications
Connections
- RS-232, Null modem configurable – (8) RJ-45 ports
- RS-485 – (2) RJ-45 ports
- IR Output, (Mono), – 12V DC – (12) 3.5mm ports
- Signal Input – (4) Terminal Block Connectors 3-pin
- Relay – (6) Terminal Block Connectors 3-pin
- HDMI 1.4b – (1) For on screen display
- USB 2.0: 5VDC / 0.5A and USB 3.0: 5VDC / 1.0A (supplied by external AC / DC adapter)
- USB 2.0: 5VDC / 0.5A or USB 3.0: 5VDC / 1.0A (supplied by PoE)
- RCA Audio – (2) Stereo audio out
- Ethernet / PoE IEEE 802.3af (802.3at Type 1) – (1) RJ-45 port
- Power (1) Coaxial Type A, 2.5mm inside diameter. 12V 2.5A
- 2.4 / 5 GHz WiFi 802.11 b/g/n/ac
System
Software compatibility: Refer to the integration note for compatibility
Updates managed by ELAN Core Module software
General
Operating Temperature: 0° to 40° C Operating Humidity: 90% Maximum (Non-
Condensing) Mounting: Free standing, Rackmount
Product Dimensions
With feet: 17” W x 2.25” H x 14” D (431.8mm W x 57.2mm H x 355.6mm D) Without
feet, with rack mount brackets: 19” W x 1.75” H x 14” D (482.6mm W x 44.45mm H
x 355.6mm D) Weight 8 lbs, 11oz / 3.95kg
Certifications
CE, FCC, C-Tick / RCM
Limited Warranty
Nortek Security & Control ( ‘NSC’ ) warrants the EL-SC-300 to be free from
defects in materials and workmanship for a period of two years (2 years) from
the date of purchase. If within the applicable warranty period above purchaser
discovers that such item was not as warranted above and promptly notifies
‘NSC’ in writing, ‘NSC’ shall repair or replace the item at the company’s
option. This warranty shall not apply (a) to equipment not manufactured by
‘NSC’, (b) to equipment which shall have been installed by other than an ‘NSC’
authorized installer, (c) to install equipment which is not installed to
‘NSC’s’ specifications, (d) to equipment which shall have been repaired or
altered by others than ‘NSC’, (e) to equipment which shall have been subjected
to negligence, accident, or damage by circumstances beyond ‘NSC’s’ control,
including, but not limited to, lightning, flood, electrical surge, tornado,
earthquake, or other catastrophic events beyond ‘NSC’s’ control, or to
improper operation, maintenance or storage, or to other than normal use of
service. With respect to equipment sold by, but not manufactured by ‘NSC’, the
warranty obligations of ‘NSC’ shall in all respects conform to the warranty
actually extended to ‘NSC’ by its supplier. The foregoing warranties do not
cover reimbursement for labor, transportation, removal, installation or other
expenses which may be incurred in connection with repair or replacement.
Except as may be expressly provided and authorized in writing by ‘NSC’, ‘NSC’
shall not be subject to any other obligations or liabilities whatsoever with
respect to equipment manufactured by ‘NSC’ or services rendered by ‘NSC’. THE
FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESSED AND
IMPLIED WARRANTIES EXCEPT WARRANTIES OF TITLE, INCLUDING BUT NOT LIMITED TO
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
ATTENTION: TO OUR VALUED CUSTOMERS
To ensure that customers obtain quality pre-sale and after-sale support and
service, Nortek Security & Control products are sold exclusively through
authorized dealers. Nortek Security & Control products are not sold online.
The warranties on Nortek Security & Control products are NOT VALID if the
products have been purchased from an unauthorized dealer or an online
E-tailer. To determine if your Nortek Security & Control reseller is
authorized, please call Nortek Security & Control at
707-283-5900.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>