CHIEF FCA113 Fusion CPU Extender Instruction Manual
- June 3, 2024
- Chief
Table of Contents
- INSTALLATION INSTRUCTIONS
- Fusion CPU Extender Accessory
- DISCLAIMER
- DEFINITIONS
- DIMENSIONS
- LEGEND
- TOOLS REQUIRED FOR INSTALLATION
- 2 ![CHIEF FCA113 - Tools 5](https://manuals.plus/wp-content/uploads/2022/12
- PARTS
- 10-24 1/4″ #10
- INSTALLATION
- Installing Fusion Mount to FCA113
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
INSTALLATION INSTRUCTIONS
Fusion CPU Extender Accessory
FCA113
DISCLAIMER
Legrand | AV and its affiliated corporations and subsidiaries (collectively “Legrand | AV”), intend to make this manual accurate and complete. However, Legrand | AV makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Legrand | AV makes no representation of warranty, expressed or implied, regarding the information contained herein. Legrand | AV assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document.
Chief® is a registered trademark of Legrand AV Inc.
DEFINITIONS
MOUNTING SYSTEM: A MOUNTING SYSTEM is the primary Chief product to which an accessory and/or component is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief product which is attached to a primary Chief product, and may have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item designed to be attached or resting on an accessory or mounting system such as a video camera, CPU, screen, display, projector, etc.
WARNING: A WARNING alerts you to the possibility of serious injury or death
if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of damage or destruction of
equipment if you do not follow the corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Failure to read, thoroughly understand, and follow all instructions
can result in serious personal injury, damage to equipment, or voiding of
factory warranty! It is the installer’s responsibility to make sure all
components are properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength for this accessory
can result in serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the structure to which this accessory
is attached can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the accessory.
WARNING: Exceeding the weight capacity can result in serious personal injury
or damage to equipment! It is the installer’s responsibility to make sure the
combined weight of all components attached to the FCA113 does not exceed 250
lbs (113.4 kg) or the maximum weight limit of the specific Fusion mount being
attached. The maximum weight that can be installed onto the FCA113 shelf is 30
lbs (13.6 kg).
WARNING: Use this accessory only for its intended use as described in these
instructions. Do not use attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is damaged. Return the
mounting system to a service center for examination and repair.
WARNING: Do not use this product outdoors.
IMPORTANT ! : The FCA113 accessory is designed to be mounted to:
- a bare 8″ concrete or 8″x8″x16″ concrete block wall, or
- a 2″ x 4″ wood studs wall covered by drywall with a maximum thickness of 5/8″.
–SAVE THESE INSTRUCTIONS–
DIMENSIONS
LEGEND
| Tighten Fastener| | Pencil Mark
---|---|---|---
| Loosen Fastener| | Drill Hole
| Phillips Screwdriver|
| Adjust
| Open-Ended Wrench| | Remove
| By Hand| | Optional
| Hex-Head Wrench|
| Security Wrench
TOOLS REQUIRED FOR INSTALLATION
concrete only
7/32″ (5.5mm) Wood Stud
3/8″ (9.5mm) Concrete
2 ![CHIEF FCA113 - Tools 5](https://manuals.plus/wp-content/uploads/2022/12
/CHIEF-FCA113-Tools-5.png)
PARTS
A (1) B (1) C (1)
[left wall bracket] [right wall bracket] [shelf bracket]
Hardware bag #1
D (4) E (4) F (4)
5/16 x 2 1/2″ 5/16″ UX10 x 60mm
Hardware bag #2
G (1) H (1)
[locking tab] #10-24 x 5/8″
J (1) K (1) L (1)
10-24 1/4″ #10
Hardware bag #3
M (4) N (4) P (4) Q (4)
5/16-18 x 5/8″ 5/16″ 5/16-18 x 3/4″ 5/16″
R (1)
[hook and loop strap]
INSTALLATION
Locate Mounting Site
WARNING: Exceeding the weight capacity can result in serious personal injury
or damage to equipment! It is the installer’s responsibility to make sure the
combined weight of all components attached to the FCA113 does not exceed 250
lbs (113.4 kg) or the maximum weight limit of the specific Fusion mount being
attached. The maximum weight that can be installed onto the FCA113 shelf is 30
lbs (13.6 kg).
IMPORTANT ! : The FCA113 can be installed to a bare 8″ concrete or 8″x8″x16″ concrete block wall, or a 2″ x 4″ wood studs wall covered by drywall with a maximum thickness of 5/8″.
IMPORTANT ! : The minimum distance between fasteners must meet the minimum distance requirements for the mount to which it is being attached.
NOTE: Proceed to either the Installing to a Wood Stud Wall section or the Installing to a Concrete Wall section.
NOTE: If already installed, Fusion mount must be uninstalled prior to FCA113 installation. Fusion hardware may be discarded as the FCA113 mounting hardware will be used to mount the FCA113 to wall.
WARNING: Mounting holes previously used to mount Fusion to wall may NOT be
reused to install FCA113 to wall! Drill all new holes for FCA113 installation.
Installing to a Wood Stud Wall
1. Determine the center of the TV screen, and where it should be located on the wall.
2. Locate the closest 2″ x 4″ stud to the left and right of the selected location.
NOTE: If the screen area lies over a stud, use that stud and the stud to either the left or right of it.
3. Line up the notches on accessory (A or B) with center of screen marking to determine vertical center. (See Figure 1)
4. Measure up 9.2″ (233.7 mm) from the center point to mark location of the upper mounting slots.
Figure 1
- Center of screen
- 9.2″ (233.7mm)
- Vertical center of accessory
5. Using a level, mark the wall on each stud to attach the brackets through the upper mounting slots. (See Figure 2)
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING OR DRILLING INTO ELECTRICAL CORDS
OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area
behind mounting surface is free of electrical wires and cables before drilling
or installing fasteners.
WARNING: EXPLOSION AND FIRE HAZARD! CUTTING OR DRILLING INTO GAS PLUMBING
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area behind
mounting surface is free of gas, water, waste, or any other plumbing before
cutting, drilling, or installing fasteners.
6. Drill one 7/32″ (5.5mm) pilot hole in each stud.
7. Use two 5/16 x 2-1/2″ lag bolts (D) and two 5/16″ flat washers (E) to attach top of brackets (A and B) to wall. (See Figure 2)
NOTE: If desired CPU location is off to the side of the display, reverse brackets (A and B) from how they are shown in Figure 2.
Figure 2
*reverse brackets to install CPU shelf to the outside
8. Mark the attachment points for the lower mounting slots, making sure the attachment points are located on the studs. (See Figure 2)
9. Drill 7/32″ (5.5mm) pilot holes at markings for lower mounting holes. (See Figure 2)
10. Use two 5/16 x 2-1/2″ lag bolts (D) and two 5/16″ flat washers (E) to attach the accessory to the wall through the lower mounting holes. (See Figure 2)
11. Proceed to Installing Shelf to Brackets Section.
Installing to a Concrete Wall
1. Determine the center of the TV screen, and where it should be located on the wall.
2. Line up the notches on bracket (A and B) with center of screen marking to determine vertical center. (See Figure 1)
3. Measure up 9.2″ (233.7mm) from the center point to mark location of the upper mounting slots. (See Figure 1)
4. Using a level, mark the wall through both upper mounting slots. (See Figure 3)
IMPORTANT ! : The minimum distance between fasteners must meet the minimum distance requirements for the mount to which it is being attached.
WARNING: INSTALLING THE FCA113 INTO UNDERRATED OR DAMAGED CONCRETE CAN LEAD
TO SERIOUS INJURY OR DAMAGE TO PRODUCT! When installing into concrete, only
install the FCA113 into concrete at least 8″ in depth or into 8″x8″x16″
concrete blocks! Never install the FCA113 into cracked, chipped or flaking
concrete.
IMPORTANT ! : The FCA113 accessory is designed to be mounted to a bare 8″ concrete or 8″x8″x16″ concrete block wall with NO wall covering!
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING OR DRILLING INTO ELECTRICAL CORDS
OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area
behind mounting surface is free of electrical wires and cables before drilling
or installing fasteners.
WARNING: EXPLOSION AND FIRE HAZARD! CUTTING OR DRILLING INTO GAS PLUMBING
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area behind
mounting surface is free of gas, water, waste, or any other plumbing before
cutting, drilling, or installing fasteners.
5. Drill one 3/8″ (9.5mm) pilot hole with a depth of 3 1/2″ (88.9mm) at each marking. (See Figure 3)
6. Install a UX10 anchor (F) into each pilot hole using a hammer, making sure that the anchor is flush with the wall. (See Figure 3)
NOTE: If desired CPU location is off to the side of the display, reverse brackets (A and B) from how they are shown in Figure 3.
7. Use two 5/16 x 2-1/2″ lag bolts (D) and two 5/16″ flat washers (E) to attach top of brackets (A and B) to anchors in wall. (See Figure 3)
8. Mark the attachment points for the lower mounting slots. (See Figure 3)
9. Drill one 3/8″ (9.5mm) pilot hole with a depth of 3 1/2″ (88.9mm) for each mounting hole. (See Figure 3)
10. Install a UX10 anchor (F) into each pilot hole using a hammer.
11. Use two 5/16 x 2-1/2″ lag bolts (D) and two 5/16″ flat washers (E) to attach the brackets to the wall through the lower mounting holes. (See Figure 3)
Figure 3
*reverse brackets to install CPU shelf to the outside
Installing Shelf to Brackets
1. Hang shelf bracket (C) onto right wall bracket (B). (See Figure 4)
Figure 4
2. Use #10-24 x 5/8″ carriage bolt (H), #10-24 wing nut (J), 1/4″ washer (K) and #10 washer (L) to secure locking tab (G) to right wall bracket (B). (See Figure 5)
Figure 5
3. Adjust depth of brackets depending on depth of CPU to install. Remove four screws and nuts holding adjustment screws in place and replace after desired depth is achieved. (See Figure 6)
Figure 6
4. Make all CPU connections and place CPU securely on shelf.
5. Use hook and loop strap (R) to secure CPU to shelf (C). (See Figure 7)
(bottom view)
Figure 7
Installing Fusion Mount to FCA113
1. Use four 5/16-18 x 5/8″ hex head bolts (M) and four 5/16″ washers (N) to secure Fusion rail mount to brackets (A and B). (See Figure 8)
NOTE: For some older Fusion models, four 5/16-18 X 3/4″ round head carriage bolts (P) and four 5/16″ hex nuts (Q) must be used to attach fusion mount to FCA113 using the square holes on FCA113 brackets. (See Figure 8)
Figure 8
- Fusion rail mount (example)
- square holes to use with older models
2. Install display to Fusion mount following the Fusion mount’s installation instructions.
8800-003327 Rev00
©2021 Legrand | AV
www.legrandav.com
08/2021
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P 800.582.6480 / 952.225.6000
F 877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P +31 (0) 495 580 852
F +31 (0) 495 580 845
Asia Pacific A Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P 852 2145 4099
F 852 2145 4477
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>