Introduction
Warning
This guide intends to assist in the preferred mounting, operation and usage of Viotel’s Accelerometer Node. Please read and completely understand this user guide in order to make sure the safe and correct use of the system as well as maintain the longevity of the device. Protection provided by the equipment may be impaired if used in a manner contrary to this user manual. Changes or modifications not expressly approved by Viotel Limited could void the user’s authority to operate the equipment. This product must not be disposed of in the normal waste stream. It contains a battery pack and electronic components and so should be recycled appropriately.
Theory of Operation
The Accelerometer is a low touch Internet of Things (IoT) device. It is designed to as simple as possible to install and activate, set and forget. Data is retrieved from the device via our cloud-based platform or via API to yours using the integrated LTE/CAT-M1 cellular communications. The device also uses GPS for time synchronisation where comparison of events between nodes is required. The device sensor is always monitoring for events, and can be continuously monitoring, or set to a triggered state. Remote configuration is possible to change the acquisition and upload frequency.
Parts List
Required Tools
Tools are not required for installation other than hand tools specific to your installation scenario. The following tools are required for changing the batteries
- T10 Torx Screwdriver
- Thin Needle Nose pliers
**Dimensions
**
Usage
Mounting Options
Viotel’s Accelerometer Node comes with three primary mounting options. It is recommended that a combination of two is used for optimal use
Orientation Description
Indicated Key Location
The switch that the magnetic key (Part 4) operates on the accelerometer (Part
- is located between the STATUS LED and the COMMS LED.
Operating Instructions
Operation
By default, your Viotel Accelerometer Node will be set to Off mode. To change the mode that the node is currently in; simply take the magnetic key (Part 4) and hover it over the Error! Reference source not found.. All operations and LED indications refer to firmware version: 3.02.14, please be aware future states may change some functionality
TAP INSTRUCTIONS | FUNCTION | DESCRIPTION |
---|---|---|
Tap once (while in Off) | Current Status | This will light up the LED indicating |
the current status that this system is in.
Tap once (while On)| Diagnostic| The device will quickly record 10 data
entries and upload them. Once this data has been logged, the device will
return back to its standard operation automatically.
Tap once, Tap again within 3 seconds| Upload and change status| This will
cause the device to initiate the upload and update sequence. In total; this
process should take a few seconds to complete and then set the device
automatically to a new status.
System Status
STATUS | DESCRIPTION |
---|---|
On | In this status, the device will consistently record data given the user |
defined interval, check for firmware updates, monitor for user defined
triggers and check for Magnetic Key inputs (Part 4).
Diagnostic| This status will set the data recorded interval to 3 minutes and
quickly record 10 entries along with GPS data. After approximately 30 minutes,
the device will return to its On status automatically.
Communicating| The device is currently trying to communicate with the server
to update firmware, load data and status information.
Off| The device will check for any wake-up commands, such as the Magnetic Key
(Part 3) or user defined data collection interval.
Every 7-days, the device will initiate a connection to provide status updates and check for system updates. Then it shall return to Off unless otherwise specified by the server.
System Status Indicator
System Communications Indicator
Maintenance
The product should not require any maintenance after installation. If the need to clean the product should arise, use only a damp cloth and mild detergent. Do not use any solvents as this may damage the enclosure. Only service personnel authorised by the manufacturer may open the inner enclosure. No user serviceable parts are located inside.
Changing Batteries
External Power
Please ensure the node is in Off mode. It is strongly recommended that the battery be taken out of the enclosure by following steps 1 to 4 and step 7 in the changing batteries section. A seven-pin male CNLinko plug will be required to power externally. PIN 5: Ground PIN 7: Positive Voltage POWER REQUIREMENTS: 7.5 VDC only.
Downloading Data
The only way to retrieve data is over the cellular communications. This can be activated on demand using the magnetic key. However if the device is in the field and is unable to upload data, the device is programmed to keep trying in decreasing increments to conserve battery. If after 4 days of attempting to upload, it will reboot. Data is stored on non-volatile memory; therefore it is stored when rebooted and after power loss. Data is deleted from the device once successfully uploaded.
Further Support
For further support, please email our friendly staff at support@viotel.co with your name and number and we will get back to you.
Viotel Offices Sydney Suite 3.17, 32 Delhi Road Macquarie Park, NSW, 2113 Auckland Suite 1.2, 89 Grafton Road Parnell, Auckland, 1010 Remote Offices: Brisbane, Hobart support@viotel.co viotel.co