zowieTek 90950-210 Camera Control Keyboard User Manual
- June 3, 2024
- zowieTek
Table of Contents
Zowietek Camera Control Keyboard
User Manual
Revision Ver. 1.1.0
Release 2021-10-27
Product 90950-210
90950-210 Camera Control Keyboard
Statement:
The descriptions in this manual may differ from the version you are using. If
you are having trouble during using this manual, please contact our technical
support for assistance. The contents of this manual will be updated, and our
company reserves the right to leave it without notice.
Precautions
The controller is an indispensable device in the integrated video conferencing
system, providing full control of all front-end cameras, pan/tilt and
motorized lenses. There are usually many numeric keys and function keys on
the controller. The numeric keys are used to select the camera or decoder
address, and the function keys are used to perform various control operations
on the selected front-end device. An LCD liquid crystal display is provided on
the control keyboard for displaying control commands or working states of
various monitoring programs in the system. One system use one controller for
remote control of the entire video conferencing system.
Product Overview
1.1 Product Features
- Adopt RS485, RS422, RS232 multiple interface control signals, max up to 255 cameras
- Support PELCO-D,PELCO-P and VISCA Control protocol
- Metal housing, computer keyboard button design
- Adopt 3D joystick to control the camera speed.
- Control camera rotation, zoom, aperture, focus and other camera parameter settings
- English & Chinese LCD display, displaying the real-time working status of the decoder and matrix
- With button sound prompt function
- Unique control code learning function allows customers to modify control code commands by themselves
- Any device connected with RS485 cable can be set with different protocols and baud rates separately.
- RS422 communication interface has the over-current protection ability to recover from short circuit.
- The max communication distance is up to 1200M (0.5MM Twisted Pair Cable).
1.2 Technical Parameters
Parameters /Model No|
---|---
Communication Mode| RS485 Half duplex, RS422 Full duplex, RS232 Serial Port
Baud Rate| 2400bps,4800bps,9600bps,19200bps
Interfaces| 5PIN Crimping terminal, RS232 Port
Joystick Rocker| 3D Control:Up, Down, Left, Right, Rotate)
---|---
Display| Blue screen LCD
Input voltage| DC12V±10%
Power Consumption| 6W MAX
Temperature| -10℃~50℃
Humidity| ≦90%RH (No frosting)
Dimension| 320mm(L)X179.3mm(W)X106.4mm(H)
1.3 Precautions
- LCD Screen is fragile, do not squeeze or leave under harsh light for too long.
- The joystick rocker is fragile. Do use the original package or properly packaged before shipment back.
- Make it work in the place with favourite temperature and humidity.
- Strictly follow the manual for correct connection.
1.4 Accessories List
Name | Quantity | Unit | Remarks |
---|---|---|---|
5PIN Plug | 1 | Pc | |
DC-12V Power Adapter | 1 | Pc | INPUT:100-240VAC~50/60HZ |
Certificate | 1 | Pc | |
Warranty Card | 1 | Pc |
Keyboard Buttons Analysis
2.1 Button Functions
【ESC】Exit and back to former menu.
【SETUP 】Parameter setting button :Long press 3S to enter the KBD parameter
setting status
【CAM ON/OFF 】Camera power on/off button
【AF/MF 】Auto focus / manual focus : Manual focus needs to work together with
[FOCUS]+ or [FOCUS-] button.
【SET PRESET 】Presets setting button, working together with number keys and the
[ENTER] button.
【CALL PRESET 】Call presets button, working with the number keys and the
[ENTER] button.
【AE/AAE 】Auto Aperture / Aperture priority button, working together with
【OPEN】and【CLOSE 】buttons.
【BLC ON/OFF 】: Back light compensation ON/OFF button
【MENU ON/OFF 】: MENU ON/OFF button
【HOME 】:HOME button
【RESET 】: Pan/tilt reset button
【CLR 】Clear button: clear the current inputs.
【0 】~ 【9 】Number keys :0,1,2,3,4,5,6,7,8,9.
【ENTER】Confirmation key: Confirm the current inputs.
【NEAR】Focus in: manually focus in to make far distance objects clearer
【FAR 】Focus out: manually focus out to make near distance objects clearer
【TELE 】Narrow-angle button/ Zoom-in button: increase lens magnification,
reduce the lens field of view, enlarge the monitor target.
【WIDE 】Wide-angle button/Zoom out button: reduce lens magnification, expand
lens field of view and monitoring range
【OPEN】Aperture plus button: Increase manual aperture. When the aperture is at
its maximum, the LCD screen is displayed in full white. When the camera menu
mode is turned on, the next level menu is entered.
【CLOSE 】Aperture minus button: Reduce manual aperture. When the aperture is at
its minimum, the LCD screen is displayed as black. When the camera menu mode
is turned on, the menu is returned to the previous menu.
【CAM】Address selection button: Select the address of the control device
(decoder or camera), it needs to use together with the number keys and
[ENTER] button【SET ID】Set ID button: long press 3s to set the cascade
camera protocol address.
2.2 LCD screen display
All button operations will be displayed on LCD screen. It would enter into
power saving mode (with darkest light), with initializing status displayed if
no operation for 30 seconds.
2.3 Joystick Control
(Clockwise/ Counterclockwise rotation only available for 3D design )
Operation| Output Control| Operation| Output Control| Operation| Output
Control
---|---|---|---|---|---
| UP| | Down| | Left
Operation| Output Control| Operation| Output Control| Operation| Output
Control
| Right| | Zoom In| | Zoom Out
2.4 Back Panel Interfaces
Back Panel Details: 1x 5PIN crimping terminal interface,1 x RS232 interface
,1xDC-12V power socket,3 x indicator lights as picture below:
2.5 Functional number description
Number | Label | Physical interface | Description |
---|---|---|---|
① | RS-422 | Control output(Ta, Tb, Ra, Rb) | 1.(Ta)to connect RS485+,(Tb)to |
connect RS485-
2. to connect RS422 Bus;(Ta)to connect RXD IN-,(Tb)to connect RXD IN+,(Ra)to
connect TXD IN-, (Rb)to connect TXD IN+
②| Ground| Control line to ground(G)| Signal control line to ground.
③| PW| Power indicator| The light will always be red when keyboard is working.
④| TXD| Sending data indicator| The light will flicker in green when
sending data
⑤| RXD| Receiving data indicator| The light will flicker in green when
receiving data.
⑥| DC-12V| Power input| DC12V power input
Parameter Setting and Query
3.1 PTZ Setup
E.g. With address code 28, steps to change to Pelco-P protocol and baud rate
to 9600 are as follows:
Press 【SETUP 】button for 3 seconds under normal working mode, it displays as
follows:
Then press 【ENTER】,there will be a 1sec beep sound when setting done.
Press 【ESC】 3 times to back to normal working mode.
Note: Steps to set all devices to be with same protocol and baud rate are
as follows:
Enter into the setup page and choose the corresponding protocol and baud rate.
Then all devices within 0-255 addresses are set with the same protocol and
baud rate.
3.2 System Setup
System setup includes: password setting, restore factory setting, Indicate
sound switch setting, Keyboard ID and Keyboard lock switch setting.
Here shows the steps to restore factory setting and set keyboard lock switch.
3.2.1 Password Setting
Press 【SETUP 】button for 3 seconds under working mode, it displays as follows
:
Then input the new password again ,press 【ENTER】,there will be a 1sec beep
sound when setting done. Press 【ESC】twice to back to normal working mode.
3.2.2 Restore Factory Setting
Press 【SETUP 】button for 3 seconds under working mode, it displays as follows
:
Press 【ENTER】,there will be a 1sec beep sound when setting done.
Press 【ESC】 twice to back to normal working mode.
3.3 Keyboard Parameter Setting Frame
PTZ Setup Camera address: XXX(to be set) PROTPCOL PELCO-D, PELCO-P, RULE Baud Rate 2400,4800,9600,19200 Camera address:0-255 (all set the same) Same as above SYSTEM Setup >SET PASSWORD OLD PW:old password 4 digits NEW PW(new password) 4 digits AGAIN PW:(confirm password) 4 digits LOAD DEFAU (restore factory setting) confirm? Press 【ENTER】to confirm ,and【ESC】to exit.
SYSTEM Setup| >SOUND SETUP (button sound switch setting)| ON| Move joystick right/left and press ENTER】to confirm
OFF
HOST ID SET| Keyboard address| Number 【 0 】 – 【 15 】
LEARN SETUP(keyboard lock setting)| ON| Move joystick right/left and press【ENTER】to confirm to set password
OFF
3.4 keyboard parameter query
Protocol:X
Baud rate:X| current control protocol and baud rate.
---|---
Camera query| Camera protocol:001| protocol| Corresponding protocol
Baud rate| Corresponding baud rate
System query| Model number:XXXXXXXX| Max 10 digits
Serial number:XXXXXXXX| 8 digits serial number on camera
| Device number:XX| 2 digits keyboard ID number
---|---|---
Keyboard lock (ON/OFF)| Display the current setting of the keyboard lock
Sound(ON/OFF)| Display the setting of the current button sound prompts
Typical wiring diagram
4.1Typical wiring diagram
Connection with surveillance dome camera Connection with video conference
camera
- control output: connect camera RS485+ with keyboard Ta, RS485- with Tb.
- Deputy control device: either RS485 output from DVR or keyboard is available.
4.2 Connection Analysis
4.2.1 connection between keyboard and camera
With RS422 bus connection way, the keyboard third pin (Ra) is connected with
the camera third pin TXD IN- , the keyboard fourth pin (Rb) with the camera
fourth pin TXD IN+ , the keyboard first pin(Ta ) with the camera first pin
RXD IN-, the keyboard second pin (Tb)with the camera second pin RXD IN +.
KBD CAMERA
Ra<········>TXD IN-
Rb<········>TXD IN+
Ta<········>RXD IN-
Tb<········>RXD IN+
With RS232 connection way, the KBD(10pin connecting terminal) first pin RXD is
connected with the third pin TXD of camera RS232 port, the KBD second pin TXD
with the camera fifth RXD, the KBD third GND with the camera forth pin
GND.(It is also available to connect camera with the standard RS232 port on
the KBD.)
KBD CAMERA
RXD<········>TXD
TXD<········>RXD
GND<········>RXD
The camera can be controlled by any connection way mentioned above.
4.2.2 Connection between cameras
With the RS422 bus cascade connection, the output of camera 1 is connected
with the input of camera2, and the output of camera 2 is connected with the
input of camera 3,and so on so forth. As shown below:
The RS232 cascade connection way is almost the same as that of RS422. The output of camera 1 is connected with the input of camera 2, the output of camera 2 is connected with the input of camera 3, and so on so forth.
Appendix
5.1 RS485 bus introduction:
RS485 bus, RS is the abbreviation of English “recommended standard”, 485 is
the identification number. The RS485 serial bus is widely used in applications
where the communication distance ranges between dozens of meters to more than
1km. RS485 uses balanced transmitting and split receiving, so it has the
ability to reject common mode interference. In addition to the high
sensitivity of the bus transceiver, it can detect voltages as low as 200mV, so
the transmitted signal can be recovered beyond the kilometers away. RS485
adopts half-duplex working mode, and only one point can be sent at any time,
so the transmitting circuit must be controlled by the enable signal. RS485 is
very convenient for multi-point interconnection, and many signal lines can be
omitted. RS485 can be used to make a distributed system, which allows up to
128 drivers and 128 receivers to be connected in parallel, depending on the
chip used by the driver and receiver, and the bus drive capability is limited
by the weakest capability. However, in practical applications we can extend it
with the RS485 splitter.
5.2 Transmission distance:
When a 0.56mm (24AWG) twisted pair cable is used as the communication cable,
the theoretical value pf the maximum transmission distance varies with
different baud rate: 1800 meters can be transmitted when the baud rate is 2400
bps, and 600 meters under 19200 bps. When using a thin communication cable, or
using the product in an environment with strong electromagnetic interference,
or when too many devices are connected with the bus, the maximum transmission
distance will be shortened accordingly, or the maximum distance is longer.
5.3 Connection method and terminating resistor
The RS485 industrial bus standard requires daisy chain connection between
devices. The two ends must be connected with a 120Ω termination resistor. The
two balance distances must be within 7m.
5.4 Problems probably happen during construction
In the actual application, the user often adopts the star link mode. At this
time, the terminating resistor must be linked to the two devices in the
farthest distance, but since the connection method does not meet the
requirements of the RS485 industry standard, the line distance in each device
In time, it is easy to generate signal reflection, and the anti-interference
ability is reduced, which leads to a decrease in the reliability of the
control signal. The reflection phenomenon is that the camera is not controlled
or controlled, and the self-operation cannot be stopped. For this situation it
is recommended to use the RS485 splitter. It can effectively convert the star
link to the connection method specified by the RS485 industry standard,
thereby avoiding problems and improving the reliability of communication.
Trouble shootings
Troubles | Analysis | Solutions |
---|---|---|
PTZ S surveillance Camera cannot be controlled by KBD | 1.check RS485 cable |
Step 1: Whether the RS485 A and B are reversed, Step 2: check whether the RS485 line is short-circuited when power off.
2.check the correspondence of camera protocol and baud rate settings with those of KBD
| Step 1: Check whether the current protocol and baud rate are correspondent.
Step 2: Restore the KBD default settings and then reset it.
3.Check whether the PTZ| Step 1: If the PTZ indicator light
| indicator light flickering when control.| flickers when control, then there
is no problem with KBD.
Step 2: If the PTZ indicator light does not flash when control, there is some
problem with the RS485 output of the keyboard.
Please return to factory for repairing.
---|---|---
Video conference camera can not be controlled by KBD| ** 1.check the
control cable| Make sure a right connection of the control cable.
2.check the correspondence of camera protocol and baud rate settings with
those of KBD| Check whether the current protocol and baud rate of each address
are correspondent.
Please refer to camera user manual.
Not all camera can be controlled by KBD.| 1.Inspect accessories.| Inspect all
connection cables.
2.Check settings.| Check whether the current protocol and baud rate of each
address are correspondent.
3.Probably a problem with star wiring.| Step 1: At the farthest end of RS485,
connect an impedance of 120Ω.
Step 2: Add RS485 splitter to the star connection
Some camera rotate at the same time when control.| 1.Inspect camera address
setting.| Check if the address codes of the cameras that are moving together
are the same, please stagger the address code settings.
(Note:** you need to restart after modifying the dialing switch to take
effect)
Forget the locking password| Long press the [SETUP] key to enter the system
settings and reset the password, if happened at any time.
Button silent| Enter the system settings and turn on the button sound.
Copyright Statement
All the contents in this manual and its copyright are owned by the company. No
one is allowed to imitate, copy, or translate this manual without the
company’s permission. This manual contains no guarantee, standpoint
expression or other implies in any form. Product specification and information
in this manual is for reference only and subject to change without notice.
All rights reserved. No reproducing is allowed without acknowledgement.
Read User Manual Online (PDF format)