zowietek 30631-XYZ 4K POV Microscope Camera User Guide

June 2, 2024
zowieTek

zowietek 30631-XYZ 4K POV Microscope Camera

Product Information

Specifications

  • Brand: eTeK
  • Model: 4K POV Camera
  • Trademark: NOi. (registered trademark of the Vizrt Group)

Product Usage Instructions

  1. Reading the Instruction Manual
    It is highly recommended to carefully read the instruction manual before using the camera. This will help you understand the product features and how to operate it effectively.

  2. Installation
    For safe and proper installation, follow the guidelines provided in the manual or seek assistance from a professional if needed. Incorrect installation may lead to equipment damage or pose asafety risk.

  3. Operating the Camera
    Ensure to use the camera in accordance with the instructions provided in the manual to prevent physical or electrical damage. Always handle the equipment with care.

  4. Maintenance
    Regular maintenance of the camera is essential for optimal performance. Refer to the manual for maintenance guidelines and cleaning instructions.

Frequently Asked Questions (FAQ)

  • Q: What should I do if I encounter technical issues with the camera?
    A: In case of technical problems, refer to the troubleshooting section of the manual for solutions. If the issue persists, contact customer support for further assistance.

  • Q: Can I use accessories from other brands with this camera?
    A: It is recommended to use accessories specifically designed for this camera to ensure compatibility and avoid any potential  damage.

  • Q: How do I adjust the settings on the camera?
    A: To adjust camera settings, refer to the menu options in the user interface. Follow the instructions in the manual to navigate through the settings and make changes as needed.

NOi. is a registered trademark of the Vizrt Group
It is recommended that you read this product’s instruction manual carefully before using it. To avoid physical or electrical damage to your personal safety and the equipment, please install and use this product in strict accordance with this manual or the instructions of a professional. Incorrect electrical connections or physical installation may cause permanent damage to the equipment or even threaten your personal safety.

Packing List

zowietek-30631-XYZ-4K-POV-Microscope-Camera-FIG-1

Device Interface Description

zowietek-30631-XYZ-4K-POV-Microscope-
Camera-FIG-3

Installation and connection

  1. Connect Network
    Connect the ZowieCam to a network router or with DHCP functionality using an Ethernet cable.

  2. Power Connection
    Option 1: USB-C Power
    After powering the ZowieCam with the power adapter, the status indicator light will illuminate. Option 2: PoE Power
    The ZowieCam can also be powered through Ethernet (PoE/PoE+), eliminating the need for a power adapter. When using PoE, connect the Ethernet cable to a PoE Network Switch; the cable should be at least a CATSe ethernet cable.

  3. Camera Lens
    All ZowieCams are equipped with a 4K 8-megapixel distortion­free M12 lens and fine tuned at 1 M distance in factory. CS mount mode uses CS to M 12 adapter to install the M 12 lens.
    Lens parameters:

    • F: 2.2, Focal length: 7.2mm
    • FOV(D/H/V):
    • D: 48.3°
    • H: 42.6°
    • V: 24.6°
    • For CS/M 12 mount camera, the lens focus can only be adjusted manual by physically rotating the lens. When you face the front of the camera, rotate the lens clockwise to focus far and counter­clockwise to focus near.
  4. Network Control of the Camera
    The ZowieCam offers four convenient and quick methods to access the web-based control interface.

  5. Login to ZowieCam via mDNS
    Please enter http://ZowieCam-xxxxx.local in your computer or mobile phone browserzowietek-30631-XYZ-4K-POV-Microscope-Camera-
FIG-6 Notes:
    The label locates at the bottom of ZowieCAM, and the URL address can be found in the label. It is best to take a photo of the label and save it so that you can quickly find URL the next time.

  6. IP Address
    ZowieCam’s DHCP is on by default. Please connect the H DM I/SDI output to the monitor, the IP address will be automatically displayed at the upper left corner at anytime after ZowieCam is turned on; or press the MENU button to call out the OSD menu instantly to check the IP address. Input the IP address In the browser of mobile phones or computers in the same LAN to login the web control interface.zowietek-30631-XYZ-4K-POV-Microscope-Camera-
FIG-7

  7. Login to ZowieCam by Device Discover
    If you already have ZowieCam or ZowieBox, you can also login to the new ZowieCam by device discover, log into the web control page, and click “Setting->Dashboard” to use the discovery function. After clicking “Scan”, find the serial number of the device that matches with the new ZowieCam label and click it to the web control interface of the device.zowietek-30631-XYZ-
4K-POV-Microscope-Camera-FIG-8

  8. Fail-Safe IP
    When the connected network does not have DHCP function, when ZowieCam is directly connected to the computer via a network cable, or other unknown errors occur, the IP of ZowieCam will change to a fail-safe IP (192.168.5.168). To access the web-based control interface, you need to add the 192.168.5.x network segment on your computer.
    Notes :
    Username: ad min; Password: ad min

  9. Control From Your Pad or Phone
    If users need to use mobile phone to log in the web control interface after logging in the web control interface on the computer side, please make sure that the mobile phone and ZowieCam are in the same LAN, and scan the QR code at the bottom left corner of the web page to log in the web control interface.

Notes:
AF mode camera is fine tuned focus at 1 meter object distance at factory. If your use distance is not 1 meter, or you install a new M 12 lens for the first time, you need to focus manually and then calibrate it.

  1. Log in to the ZowieCAM web page
  2. Click ‘Setting-Camera-Image-Start Calibration’, then manually twist the focus ring until it is completely sharp (clockwise is to focus far and counterclockwise is to focus near).
  3. zowietek-30631-XYZ-4K-POV-Microscope-Camera-FIG-10Then click ‘End Calibration’on the web page.

The ZowieCam button is a four directional buttons with a center and four directions: up, down, left, right, and it locates at the back panel.

  1. OSD Menu Controls
    Press the center button to access or return to the OSD menu. When the OSD menu is active, use the up and down directional button to navigate; use the left and right directional button to enter submenus or adjust numerical values.

  2. Standby
    Press and hold the button in the center direction for 3 seconds to toggle ZowieCam between standby mode and normal operation.

  3. Shortcut Buttons
    When the OSD menu is inactive, use the up, down, left, and right buttons to modify parameters .
    The shortcut buttons are related to the device model, exposure mode and focus mode. The corresponding table is as follows.zowietek-30631-XYZ-4K-POV-
Microscope-Camera-FIG-11

Tip:
If the model number written on the bottom of ZowieCam is 30631-002 or 30621-012, i.e., ZowieCam has the AF function, the button function will be modified according to the focus mode and the exposure mode, and the specific parameters are shown below;zowietek-30631-XYZ-4K-POV-Microscope-Camera-
FIG-12

Front Panel Indicator Lights

The front panel lights of the ZowieCam serve as status indicator lights during startup, with specific rules as follows:zowietek-30631-XYZ-4K-POV-
Microscope-Camera-FIG-13

After ZowieCam completes its startup, the front panel lights will function as Tally lights. When the Tally light is set to automatic mode and the encoding mode is N DI, if the N DI-encoded output is sent to other NDI receivers (such as vMix, OBS, etc.), ZowieCam will modify the Tally light color based on whether the receiver switches to Program (PGM) or Preview (PVM) mode. zowietek-30631-XYZ-4K-POV-Microscope-Camera-FIG-14

Encoding Mode

  1. Encoding Mode Switching
    ZowieCam has two working modes, normal encoding mode, and NDI encoding mode. It supports up to 4k30 output and encoding; supports encoding RTSP, RTMP(S), SRT and NDI (HX/HX2/HX3) . If you want to switch the code stream to NDI encoding mode, please login the web control interface and click “Setting->System->NDI” to make sure NDI is activated.zowietek-30631-XYZ-4K-
POV-Microscope-Camera-FIG-15 After logging into the web control interface, click “Setting­>Streaming->NDI” to open the NDI button and reboot to enable NDI encoding mode. zowietek-30631-XYZ-4K-POV-Microscope-Camera-
FIG-16

  2. NDI Connection
    Compatible software:zowietek-30631-XYZ-4K-POV-Microscope-Camera-
FIG-17

After ZowieCam is switched to NDI encoding mode, it supports most of NDI software to discover ZowieCam automatically in the same LAN, for example, selecting the device you need to play directly in NDI STool.

zowietek-30631-XYZ-4K-POV-Microscope-Camera-FIG-18

Notes:
If your computer cannot detect all NDI settings:

  • A. Check if the computer can access the web-based control interface of ZowieCam.
  • B. Please close any relevant software such as VPN.
  • C. Verify whether you are using a private or public network, and check if you have allowed all NDI software to pass through in the “Allow applications to pass through the firewall”.zowietek-30631-XYZ-4K-POV-Microscope-Camera-FIG-19

LocaI Stream

Through local streaming, users can view the consequence of encoding settings in real time on the same LAN by rtsp stream.

  1. Click “Streaming->Local” in the web control interface.
  2. Click the icon on the right to copy the URL of the primary or secondary stream.zowietek-30631-XYZ-4K-POV-Microscope-Camera-FIG-20

Internet Stream

Add tasks in this interface to streaming to public CON (Content Delivery Network).

  1. Click “Streaming->Live” on the web page.
  2. Click “+Add” to create a new network streaming task.
  3. Select the same protocol as the streaming address and enter the streaming address and key, if you don’t have the streaming key, you can skip it.
  4. Enter the name of the network flow task and click “Save”, the name will be displayed in the preview interface for operation.
  5. Turn on “Test” to start pushing stream.

zowietek-30631-XYZ-4K-POV-Microscope-Camera-FIG-21

Restore Factory Settings and Reboot

  1. Restart ZowieCam
    Click “System->Default->Restart” in the web control interface.

  2. Restore ZowieCam to factory settings:

  3. Click “System->Default->Restore factory default settings” in the web control interface.

  4. Click the panel button MENU to bring up the OSD and select Restore Factory Settings.

Firmware Upgrading

  1. Click “System->Default->Restart” in the web control interface.
  2. Click to select the file to upload the correct firmware.
  3. Click to upgrade.

Notes:
After clicking Upgrade, ZowieCam will be automatically upgraded and reboot. This process will take a few minutes. During this period, please keep the network of ZowieCam smooth and stable power supply, otherwise it will lead to upgrade failure.

Warranty

We offer your 4K POV Camera one-year hardware warranty Lifetime software maintenance For answers to FAQs and information, please visit:
https://www.zowietek.com/knowledge-base6 https://www.zowietek.com/
Or contact us:
support@zowietek.com
+86-21-50277371, 50277372

A professional video camera, streaming, and recording solution provider Since 2004
Zowietek Electronics, Ltd.
2218 Hunan Road, West Wing 1701 Pudong, Shanghai, China
PN:30631-XYZ
is a registered trademark of Zowietek Electronics, Ltd.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals