WILDLIFE Computers sPAT User Guide
- June 3, 2024
- WILDLIFE
Table of Contents
WILDLIFE Computers sPAT
Almost Everything You Need to Know About the sPAT
The sPAT is ready to deploy when you take it out of the shipping box. Wildlife Computers preprograms your sPAT with the desired deployment duration (30, 45, or 60 days) and ships the tag in Auto Start mode so it begins its deployment as soon as the sensor hits sea water.
The rest of this user guide is helpful if you are curious about everything sPAT, if you need to change the deployment duration or release conditions, or if you recover your tag and want to download the archive. If none of these situations apply to you, you can stop reading here.
In the guide, you will see the yellow icon highlighting information where special attention should be paid.
The sPAT (also known as a PAT tag or PSAT) is a pop-up archival transmitting tag specifically optimized for short-term survivorship studies. The sPAT uses a suite of sensors and algorithms to monitor the status of the tagged animal for up to 60 days. Users can deploy the sPAT on by-catch, fish, shark, rays, skates, eels, and turtles. The sPAT is designed to be attached to an animal by a tether. The corrodible burn pin releases the tag from the tether on a pre- programmed interval (30, 45, or 60 days) or when the sPAT determines it is no longer attached to an animal. Data transmission occurs when the tag floats on the ocean surface after it releases from the tether.
Tags are shipped pre-programmed with default settings and in auto-start mode—the sPAT automatically starts the deployment when submerged in saltwater. At any time, a single pass of a magnet near the communication’s port will cause the LED to gradually transition from bright to dim as confirmation that the tag is in auto-start mode.
Figure 1— sPAT tag rigged with a stainless- steel heat shrink-covered tether and a Wilton anchor.
Transmitted data will allow you to infer the status of the animal at the time of release. Data generated during a deployment includes:
- Daily Data for the entire deployment.
- Minimum and maximum temperature and depth readings
- Delta (difference between min and max) light-level for each UTC day
- 10-minute time-series depth data for the end of the deployment to help determine the animal’s fate
- The Argos generated pop-up location.
The sPAT will transmit for approximately three days and the data will show up in your Wildlife Computers Portal account as it is received.
Before you Begin
The list below shows what is required to communicate with the sPAT:
- A Wildlife Computers online portal account
- A Windows computer with Tag Agent Software and USB driver installed
- A Wildlife Computers USB communications cable
- A magnet
Visit wildlifecomputers.com to download the required software (Tag Agent and the USB Driver) and setup an account. At the end of this document, there is a list of key terms and concepts for reference. We recommend new users review this list.
Anatomy of a Tag
Figure 2 – sPAT tag showing: (a) Argos antenna, (b) temperature sensor, (c) communications port with plug, (d) light sensor (1 of 2), (e) float, (f) release pin, (g)
LED light, (h) wet/dry sensor, (i) ground plate, (j) light sensor (2 of 2),
and (k) pressure sensor.
The communications port is where the USB communications cable plugs into the
tag. Prior to a deployment, this port should be sealed with the plug provided.
Smear a small amount of the silicone grease supplied onto the sides and bottom of the plug, align the plug and pins, and carefully push the plug into the port. If it does not align easily with the pins, rotate it 180° and try again. The plug prevents corrosion of the pins during the deployment; however, the plug is not required for the tag to function normally.
The wet/dry sensor, ground plate, pressure sensor, thermistor, and electronic
release pin should never be covered.
Covering these sensors interferes with the tag’s functionality. This includes
antifouling coatings, brightly colored paints for recovery purposes, and
attachment adhesives (e.g. epoxy).
Types of Data Received from sPAT
Daily Data
Daily data messages contain the minimum and maximum temperature and depth
readings from the fast-sampled archive data set, as well as the change in
light-level for each UTC day.
Time Series
The sPAT tag sends ten-minute time-series depth data for the end of the
deployment. If the tag releases on the scheduled day, it will send four days
of time-series depth data. If it is a conditional release (see Tag Release
Sequence section) the tag will send time-series depth data for the four days
of data prior to the beginning of the conditional release period plus the
entire conditional release period. Each time-series message contains:
- Time series depth data at a ten-minute interval
- The minimum/maximum values encountered during the time period covered by the time- series message period
The absolute Min/Max values and point sample values may not match as the absolute values are determined from all archived data collected during the message period. This can give insight to the amount of aliasing that has occurred when generating the time-series message.
Time-series Sensor Resolution
Time-series sensor resolution will vary for each measurement. All time-series
sensor readings have an associated resolution which is reported in the decoded
data. The resolution is dynamically adjusted to compress the data for
transmission.
Tag Release Sequence
The sPAT will be pre-programmed for your desired deployment duration (30, 45,
or 60 days). The tag will begin the release sequence when that specified
interval is reached unless a conditional release occurs prior to reaching the
intended duration.
Conditional Release
The sPAT uses sensor measurements to make reasonable assumptions about the
state of the deployment. Depending on your study design and the behavior of
your study animal, you can program the tag to release and begin transmitting
if certain conditions are met.
Auto-detect Tag Detachment
The parameter automatically initiates release if the tag detects itself
floating at the surface.
- Select a depth threshold that the tag must exceed before monitoring for detachment. This helps prevent triggering a conditional release before the tag is attached to its host animal. For example, if you program a sPAT tag and put it in Start mode using Tag Agent (while tag is attached to your PC) it will detect constant depth while it’s sitting on your desk.
- Select how long the tag must be at the surface before a release will occur. The pin burn will occur after the specified time has elapsed
Auto-detect Mortality
This parameter monitors for three mortality conditions:
- Floater—the tag is floating at the surface (more than 50% of the wet/dry readings for every hour of the interval is dry, OR if the maximum depth during the premature release interval was <= one meter)
- Sitter—the tag is sitting at a constant depth
- Sinker—the tag remains below a certain depth
Upon satisfying any one of these conditions, the tag automatically initiates release. To monitor for mortality, configure the following:
- Select a depth threshold that the tag must exceed before monitoring for detachment.
- Optionally, select the depth that the tag must remain below to be considered a sinker.
- Select the duration—this sets how long each of the depth criteria must be maintained before a release will occur. The pin burn will occur after the specified time has elapsed.
- Select the variance—variance is used here in a statistical sense (see Figure 3). Be mindful of the tidal activity in your study area. A tag stuck on the bottom will detect some minor depth changes as the tides change the water depth. If you choose a range that is too small for local tidal conditions, the tag will not initiate a conditional release when it is stuck or sitting on the bottom.
The release settings shown in Figure 3 will result in the following:
- The tag will release 30 days after deployment.
- The tag will release if it exceeds 10 meters in depth and then meets any of the following criteria:
- Stays within four meters (+/- two meters) of a constant depth for more than one day.
- Stays deeper than 400 meters for more than one day.
- The tag will release if it reaches a depth of 1700 meters. This ensures that if the tag is sinking it will not reach its crush depth and become inoperable (this setting is not adjustable).
Release reasons as reported in the tag’s status messages:
- Interval—the tag ran to the configured end of the deployment and the animal survived.
- Pin Broke—the tag sensed the release pin was broken, and the tag found itself floating on the surface for an extended period of time. Some external force pulled on the tether and broke the pin.
- Floater—the tag stayed within four meters of a constant depth for more than one day and was dry for the majority of time. For some reason (mortality or attachment failure) the tag has come off the animal and is floating at the surface.
- Premature—the tag stayed within 4m of a constant depth for more than one day. The tag could be sitting on the bottom, attached to a dead animal. This could also be a floater but the tag wasn’t dry for the majority of the time. Examine the Depth Time Series data to make final determination.
- Too Deep—the tag detected that it was getting dangerously close to its maximum structural depth. The animal was dead and sinking or diving to a depth that is too deep for tag. Examine the Depth Time Series data to analyze sink rate.
Pinger
The pinger is used for tag recovery. The sPAT sends out low power “pings”
after release while at the surface. The tag can be located with an appropriate
receiver and directional antenna. The sPAT will ping at a one second interval
for the duration of the Argos transmission period (approximately three days
after release).
Interacting with a Tag
The sPAT will be shipped pre-programmed by Wildlife Computers. In the case
where you need to change the deployment duration, release parameters, or if
the sPAT is recovered after a deployment, follow the instructions below to
communicate with the tag.
Tag Agent Software is used to communicate with the sPAT. Tag Agent and the USB Driver can be downloaded from our website: wildlifecomputers.com .
Plug the USB communications cable into the computer and connect to a tag carefully observing the orientation of the connector pins. The home page will display with Tag Status as Interactive in the lower left with tag information and sensor readings visible. If tag status remains Disconnected, swipe the magnet supplied near the communication port on the tag to view the tag in interactive mode.
Figure 4–Tag Agent software connection screen.
If the tag is new or has previously been programmed by another user, a pop-up box will appear asking if you wish to take ownership of the tag. Becoming a tag administrator gives you the authority to select and save new settings.
If tag settings have been updated through the portal using My Tags, a pop-up box will appear on opening Tag Agent advising that changes have been made and the tag’s settings need to be updated.
The Administer Tag button allows you to modify the settings of the connected
tag. Click the Send Changes button on the left of the screen to activate these
changes.
The Download WCH tab shows a summary of data on the tag and gives you the
option of downloading the archive and set-up info onto your local machine.
Figure 5—Tag Agent home screen.
Configuring Deployment Duration
To change tag Deployment Duration within Tag Agent, select the Administer Tag
button in the upper menu.
Figure 6—Tag Agent menu bar. Select Administer Tag to edit tag release settings.
A new window will open up revealing three sections—Tag Information, Tag Release Sequence, and Transmission Settings.
Tag Details & Argos Settings
Figure 7—Expanded view of Tag Details tab.
Tag administrators, tag ware version, and tag type are displayed on the Tag Details tab. Tag Name is an optional field which makes a tag or tags easy to find in the
Tag Portal using the filter. The Argos Settings tab displays the tag PTT ID details.
For more information on these terms, reference the Key Concepts section at the
end of this document.
In the Tag Release Sequence section, you can choose to release the tag 30, 45,
or 60 days after the deployment start. You can also adjust the Conditional
Release settings.
Figure 8—Tag Release Sequence.
Once settings have been chosen, use the blue Send Changes button (or Propose Changes button if working in Tag Portal) to load settings into tag. Tag Agent will confirm receipt of settings via dialog box. The Check for Updates tab on the top left navigation bar of Tag Agent home screen can be used at any time to see if settings updates are available.
Tag States: Start, Auto Start, and Stop
The sPAT has three states: Auto Start, Start, and Stop.
- A tag in auto start mode can be activated by sea water submersion. Wildlife Computers ship sPATs in Auto Start.
- Start mode activates the tag. In Start, data collection is running and the tag begins monitoring for its set release condition.
- Stop puts the tag into deep shutdown for storage. The tag will remain unresponsive unless connected to Tag Agent.
Disconnect from the sPAT
To disconnect from a tag, use the Disconnect Tag tab on the top right
navigation bar. Do not simply unplug the USB communications cable.
The communications port should be sealed with the plug provided. Smear a small amount of the silicone grease supplied onto the sides and bottom of the plug, align the plug and pins, and carefully push the plug into the port. If it does not align easily with the pins, rotate it 180° and try again. The plug prevents corrosion of the pins during the deployment; however, the plug is not required for the tag to function normally.
Tags in Stop mode need to be connected to Tag Agent through the USB cable to awaken the tag.
LED Blink Patterns
Within Tag Agent, the Disconnect Tag button on the top right navigation bar
can be used to put a tag in any state. Wildlife Computers ships the sPAT in
Auto-Start mode.
Once disconnected in Auto-Start:
- At any time, a single pass of a magnet near the communications port will cause the LED to gradually transition from bright to dim as confirmation that the tag is in Auto-Start mode.
- The LED turns on if the tag gets wet for a few seconds while in Auto-Start mode. After remaining wet for approximately ten seconds the LED blinks ten times, the archive is erased, and deployment begins.
- The reset switch is disabled once the tag has been “mostly wet” for at least one hour—magnets no longer affect the tag unless the tag is connected to Tag Agent and reset.
- If the tag gets wet while in Auto-Start mode, but not long enough to enter “deploy” mode as above, the LED gradually goes from bright to dim and remains in Auto-Start mode.
- You can put the tag back Auto-Start mode by swiping it with a magnet within the first hour of a deployment. You will see the LED come on and gradually transition from bright to dim.
Clearing the sPAT Archive
The archive is cleared automatically when a new deployment is started. The LED
will indicate that the tag is clearing the archive with many rapid blinks.
Leave the tag connected until Tag Agent indicates that the archive has been
erased. This may take several minutes. Be mindful of this when selecting the
tag state. If a tag is recovered, be sure to download the data prior to
putting back in Auto-Start or Start mode.
Gathering Tag Information
Checking Sensor Readings & Transmission Test
The sensor values displayed on the Tag Agent home screen are continuously
updated from the tag. Sensor functionality can be validated by manipulating
the sensors as follows:
-
Ambient Temperature—responds quickly to warm air blown onto the thermistor located immediately above the communications port.
-
Internal Temperature—this will change slowly as the entire tag changes temperature. Leaving a tag in a refrigerator for a while will change the value.
-
Wet/Dry—connecting a wire from the large rectangular ground plate strap above
the communication port to the metal ring around the base of the antenna (letters i and h respectively in fig. 2) should change the value from over 200 to less than 20. -
Light-Level—under typical office lighting, covering both light sensors (shiny squares on opposite sides of tag, letters d and j in fig. 2) with your fingers should drop the value by 20 to 40 counts.
Test Transmission
Under the Advanced button on the top menu there’s an option to Send Test
Transmission. When selected, a pop-up box with transmission values will
appear.
Figure 9—Test transmission results.
The Battery Voltage value will be lower in the pop-up box than on the Tag
Agent home screen because it is measured when the battery is driving a
transmission.
The Transmit Current will vary depending on the presence of conductive objects
near the tag. It has been optimized for a tag that is floating in seawater.
Transmit Count is the number of transmissions the tag has made since it was
manufactured.
Argos Transmitter Test
The Argos Transmitter test allows for a full system test to confirm that the
tag is successfully sending messages to the Argos satellites. Click on the
Advanced Tab then Argos Transmitter Test.
- Seconds Offset: If you will be testing multiple tags at one time, you can use this parameter to offset transmissions so the tags will not transmit at the same time.
- Transmit Count: How many times you want the tag to transmit. 120 transmissions at a 60 second interval will provide a 2-hour test, which is usually enough to coincide with a couple of satellite passes. Check the satellite passes in your area prior to beginning the test.
- Seconds Apart: The time between each transmission.
- When all of the tags are setup and deployed, take them outside where they have a full view of the sky. For best results, float the sPATs in a bucket of saltwater.
Upon completion of the Argos Transmitter Test, the tag will be in STOP mode and you will need to communicate with it again prior to deploying it.
Using Tag Portal to Select Settings Remotely
Tag Portal is the cloud-based service offered by Wildlife Computers for
remotely selecting tag settings. Configuring can be done without connecting to
your tag. This enables project coordinators to review and select settings for
their associates and programming to be done while tags are in transit, before
arrival.
When logged into your Portal account, a list of the tags which you have
administrator power over can be viewed under the My Tags tab. To select
settings, click on the serial number of the tag you wish to configure or use
the pencil icon.
Figure 10—List of tags within Tag Portal. To program select the serial number or pencil icon.
This will open a new window with setting selections. The same programming
options are available whether settings are configured via Tag Portal or from
within Tag Agent.
Once settings have been selected in Tag Portal, click the blue Propose
Changes. This will save the settings in the cloud. The next time that tag
communicates with Tag Agent (no matter who plugs the tag in), a dialog box
will appear notifying that new settings are awaiting upload.
Multiple set-ups can be published resulting in a queue of configurations
awaiting upload. In this case, a dialog box will reveal a list of the
configurations published, when they were selected, and which administrator
chose the settings.
Tag Portal maintains a historic record of tag settings each time changes are
uploaded into a tag. The record is instantly updated so long as an Internet
connection is available.
If tags are programed offline, using Tag Agent, the next time an Internet connection is established and Tag Agent software is open, the record automatically updates.
Offline Mode
Before you can program offline, you must download Tag Agent software and
communicate with a tag while connected to the Internet. You can simulate
offline mode by disabling your Internet connection.
What You Need Before You Begin
- A Windows-based computer with Tag Agent software and USB driver installed. Download both at WildlifeComputers.com
- A Wildlife Computers Portal account
- A USB communications cable
- A Magnet
- One of every tag type (i.e. sPAT, SPOT, SPOT-F, MiniPAT) you are taking in the field
While Connected to the Internet
- Open Tag Agent and use the USB cable to connect a tag to your computer.
- Swipe a magnet near the communication port to establish connection. The tag LED will turn on and the Tag Agent home screen will appear.
- Use the Administer Tag tab to familiarize yourself with the tag setting options.
- Use the Disconnect Tag tab to select the tag state before unplugging.
If you are headed into the field with multiple tag types (i.e. sPAT, SPOT, SPOT-F, MiniPAT, etc.) be sure to communicate with one of each model while you have an Internet connection.
Using Offline Mode
Working offline is nearly identical to working online. Internet status is
displayed in the lower left corner.
Figure 11—Internet status.
If the Internet connection is spotty, it is best to disable the connection entirely. A partial connection can prohibit settings from loading properly.
Programing Tags
- Open Tag Agent and use the USB communications cable to plug a tag into your computer.
- Swipe a magnet near the communication port to establish a connection.
- If the tag’s internal clock needs adjusting, a pop-up box will appear along with a Date/Time Picker. Hint—sometimes the Picker hides in the upper left corner of the screen.
Figure 12-Pop-up boxes for date/time.
- Click the Administer Tag tab and make the required changes to the tag settings.
- Click Send Changes to push settings into the tag. A pop-up box will confirm the new settings have been applied.
Figure 13-Pop-up confirming new settings.
- Use the Disconnect Tag tab to select the tag state before unplugging.
- Restart Tag Agent when the Internet connection is restored so a record of the selected tag settings will be saved.
Creating Local Templates
You can program a group of tags with the same settings using a local template.
Click the Administer Tag tab and use the Template Manager icon in the upper
right corner of the screen to create and apply templates.
The Send Changes button must be selected after a template is applied to push
settings into a tag.
sPAT Recovery Instructions
If the sPAT is recovered after deployment, it is possible that contamination
of the communications port may cause some communication difficulties. The
following instructions, in addition to describing how to recover the data,
explain possible problems that might occur during the recovery and how to fix
them.
Even if all attempts to communicate with the sPAT fail, your deployment data are probably still in memory, and can be retrieved by Wildlife Computers.
Preparation for Post-Deployment Communication
When you recover your sPAT full of valuable deployment data, there are several
steps to perform before attempting to connect it to the USB communications
cable. As a precaution, it is advised to have the following on hand:
- Compressed air in a can
- Electronic contact cleaner, if available
-
Thoroughly dry the sPAT with a paper towel.
-
Remove the rubber communications port protection plug.
-
Blow out any water in the communication port. Make sure the port is clean and dry. Compressed air in a can works well for this.
Communicating with a sPAT which has saltwater in the communications port will cause the pins to corrode very fast! -
Count the number of pins in the communications port. If there are not four pins, one or more have corroded or broken off. Stop there and send the sPAT to Wildlife Computers, and we will download your data.
-
Examine the pins in the communications port. If they are rusty or corroded, send the sPAT back to Wildlife Computers for downloading.
-
If all four pins look clean and golden in color, you can continue and attempt to establish communications.
-
You may wish to spray some contact cleaner into the communications port as a precaution.
If you are able to establish a communication connection with the tag, you are now ready to download your data with Tag Agent.
Download your Data
Use the Download WCH button on the Tag Agent top navigation bar to download
SPAT archival data
(Figure 11). You’ll be prompted to save the .wch file to your computer. The
file can then be uploaded into the Data Portal for decoding, analysis, and
storage.
Put tag into Stop mode after downloading the data.
Figure 14—Tag Agent menu bar. Select Download WCH to download archived data.
Tag Storage and Battery Maintenance
Proper tag storage is important to minimize passivation and keep the batteries charged. When stored correctly, the amount of battery life lost per year is only 1-2 percent.
sPAT Storage—Less Than One Month
Not much needs to be done as you will be deploying them soon. Wildlife
Computers recommends storing tags in a cool, dry environment—ideally around
+5° C.
sPAT Storage—Longer Than One Month
If you will be storing sPAT tags longer that one month, you will need to place
your tag in “Stop” mode using Tag Agent and exercise the batteries every 3
months.
Connect to each tag and login to Tag Agent. In the menu at the top, you will
see the “Disconnect Tag” tab. Scroll down to “Stop.” The tags can now be
stored. Wildlife Computers recommends storing tags in a cool, dry
environment—ideally around +5° C.
Once tags are stored, they must be “exercised” by sending test transmissions in Tag Agent. Connect to each tag and log into Tag Agent. In the menu at the top, you will see the “Advanced” tab. Scroll to select, “Send Test Transmission.” The test transmission voltage should read approximately 3.3v and the battery voltage displayed on the main sensor screen should be around 3.5v.
If you receive a low voltage reading, it may be due to passivation forming during storage. We recommend repeating this test at least 3-10 times to dislodge the possible passivation layer. If you continue to receive a low voltage reading, anything less than 3.2v, contact your technical sales consultant.
Technical Specifications
Dimensions | 124 mm (length) X 38 mm (diameter) |
---|---|
Weight in Air | 60 g |
Pressure Rating | 2000 m |
Memory | 64 MB |
Operating Frequency | 401.678 MHz |
Operating Life | Up to two years |
Sensors | Light, Pressure, Temperature, Wet/Dry |
Light | 5×10-12 W/cm2 to 5×10-2 W/cm-2 |
Pressure | Range: 1700 m/Resolution: 0.5 m |
Temperature | Range: -20° C to 50° C/Resolution: 0.05° C |
Conductivity Operational Limits | 0.1 to 5 S/m |
Storage Temperature | 5° C Optimal |
Communication | Via USB port using Wildlife Computers USB communications cable |
Additional Information
Glossary of Terms
-
Administrator—someone who has the authority to publish tag settings.
-
Argos ID—uniquely identifies a transmitter for the Argos system. The ID consists of a decimal number and a hexadecimal (base 16) number.
-
Argos location—a location generated by the Argos system from uplinks received during a satellite pass. Get more information about how the Argos system works here: www.argos-system.org
-
Argos uplink—a radio transmission intended for the Argos satellite system.
-
Daily Data—generated from sensors over a fixed 24-hour period.
-
Data message—created by the tag to transmit data through the Argos system. Each data message is transmitted as payload in an Argos uplink. In order to increase the likelihood of its reception by the Argos system, each message is sent a fixed number of times.
-
Data Products—the various types of data available from Wildlife Computers tags.
-
Deployment—the period when a tag is associated with an animal and actively collecting and sending telemetry data.
-
Location uplink—a transmission intended to generate an Argos location. These uplinks can also carry a data message payload. Multiple uplinks are required to generate an Argos location.
-
Pinger—a UHF radio tracking beacon.
-
Repetition Interval (repetition rate)—how often a tag will test for dry conditions and try to transmit.
Set at 90 seconds for sPATs, this value is assigned by CLS (Argos) and set by Wildlife Computers. -
Start/Auto Start/Stop—the different tag states. When in Start mode, the tag will generate locations and/or collect sensor data. Auto Start will allow the tag to Start using a magnet or when reading wet. Stop causes the tag to do nothing until reconnected to Tag Agent.
-
Summary Period Data—generated from sensors during a defined number of hours.
-
Tag Agent Software—the program used to change tag states and select tag settings and connect a tag to the Wildlife Computers Tag Portal.
-
Tagware—the software version running on a tag.
-
Tag Portal—the cloud-based service offered by Wildlife Computers for remote tag setup. A historic record of tag settings and templates are maintained within the Tag Portal.
-
USB Communications Cable—the Wildlife Computers communication cable required by Tag Agent.
-
Wet and Dry—the state of the tag as determined by the wet/dry sensor which measures conductivity.
Understanding Antifouling Paint
Heavily fouled tags can be hugely detrimental to tagging studies as fouling
growth over critical sensors can impede the tag’s transmitting performance.
Especially for deployments in tropical waters, it is imperative that tags be
protected against marine growth. Wildlife Computers endorses two antifouling
paints, Micron and Propspeed. While we prefer Micron66, it is not available in
some countries. There are dozens of paint options available, but Micron 66,
Micron77 and Micron99 are our favorites from years of testing and client
feedback.
Micron66 is a copper-based antifouling paint that has a biocide which repels
barnacles. For optimal protection, it is critical to use International Paints’
Interprotect primer in addition to several coats of paint. Micron66 is a great
choice for slow movers like sea turtles and whale
sharks—http://bit.ly/Micron66
Propspeed is non-toxic and widely available. Its glossy texture sloughs off
marine growth before it has a chance to bond. Constant water flow is key to
Propspeed’s effectiveness making it most beneficial for active swimmers.
Wildlife Computers offers an optional service to sand, mask, and paint tags
with Propspeed antifouling and coat the wet/dry sensors with conductive
polymer. This comprehensive antifouling service is offered at a charge of $100
per tag prior to shipping. We do not apply Micron antifouling paint due to the
hazardous nature of the product.
Tips and Tricks When Antifouling Your Tags
Here are a few critical points to ensure successful tag antifouling:
- Mix the Micron paint with a battery drill and paint mixer tool—this step is imperative to dislodge the copper off the bottom of the can! If you can’t use a drill, mix it thoroughly with a wide paddle to ensure all the copper sludge is mixed into the paint.
- After covering the wet/dry sensors, communications port, depth sensor opening, “Battery Isolator” screw, and LED viewing port with tape, prime the entire tag including all the antennas when applicable—Fastloc® GPS patch antennas, Fastloc® GPS whip antenna, and the Argos antenna.
- Only prime two to three tags at a time and ensure that the first coat of Micron paint goes on when the primer is tacky and not dry (if too late, apply another coat of primer and then paint when tacky).
- Apply three to four coats of Micron, allowing time to dry between coats (it is ablative, so it needs several coats that will wear off over time in the water).
- Remove masking tape!
- Optionally, apply another coat to the Fastloc® GPS and Argos whip antennas after attaching the tag (especially to a turtle). Remember to avoid the wet/dry sensors. Micron will not harm the attachment epoxy.
Check out our antifouling resources on the Wildlife Computers website including a video that shows you exactly how to do apply antifouling paint.
Resources
International Paints Micron Antifouling Paint Micron is only available in
5-liter (one gallon) cans.
http://www.yachtpaint.com/LiteratureCentre/micron-66-info-usa-eng.pdf
USA Store Locator: http://www.yachtpaint.com/usa/diy/store-
locator/search.aspx
Micron is available in the USA and Asia-Pacific regions from International
Paints dealers and ship chandlers. Micron is not available in all countries.
Similar Micron products such as Micron Extra, Micron Extra2, MicronCSC, Micron77 and Micron99 are alternative solutions although Micron66, Micron77 and Micron99 are the most effective. Micron77 may only be available from licensed applicators.
International Paints Primer
****“Interprotect 2000E” or “Interprotect” or “Gelsheild 200” (These are the
same product). Inter protect is a two-part epoxy primer and is available in
750ml, (one quart) cans.
If Interprotect primer is not available then “Primocon” primer can be used but
it is not as effective.
Contacting Wildlife Computers
U.S. and International
Members of the Wildlife Computers technical sales and support team are located
in Redmond, WA, USA, and Havelock North, New Zealand, allowing us to cover
promptly a wide range of time zones.
Mailing and Shipping
Wildlife Computers
8345 154th Avenue NE
Redmond, WA 98052 USA
Email
Sales, Quotes, and Inquiries:
tags@wildlifecomputers.com
Technical Support:
support@wildlifecomputers.com
Phone
+1 (425) 881 3048 For Asian Clients
Website WildlifeComputers.com
While we welcome your direct correspondence, we recommend that you contact our colleague, Yong Huang, for assistance. Mr. Huang understands the special purchase processes for your countries, and will provide you with the best service for the best price. He also is fluent in Japanese, Chinese, and English.
Mailing Address—Please ship tags to our main office in Redmond, WA.
Yong Huang
Enfotran Corporation
816 Evergreen Point Road, #217
Medina, WA 98039 USA
Email
yong.huang@enfo.us
Phone
+1 (425) 456 0101
Fax
+1 (425) 456 0303
The information contained in these documents is confidential, privileged and only for the information of the intended recipient and may not be used, published or redistributed without the prior written consent of Wildlife Computers.
References
- bit.ly/Micron66
- system.org at Directnic
- Home - Wildlife Computers Inc.
- Interlux Yacht Paint: Paint your boat like a pro
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>