GENERAL LIFE HT300S RF Digital Room Thermostat
Specifications
- Wireless room thermostat
- Daily and weekly programming
- Different mode options (Comfort, Economy, Holiday)
- Heating calibration
- ON/OFF control
- Wireless connection
- TPI algorithm
- Precise temperature measurement
HT300S RF and EQUIPMENTS HT300S RF
- Room Thermostat
- Holder
- Alkaline Battery (AAA)
- Receiver
- Dowels and Screws
Technical Data Room Thermostat
- Dimensions: 85mm / 125mm / 20mm
- Operating Current
- Temperature Measurement Accuracy
- Operating Temperature Range
- Battery Life
- Operating Temperature
- Storage Temperature
Product Usage Instructions
Installation
Follow the steps below to install the HT300S RF:
- Choose a suitable location for the Room Thermostat in the roomthat is used most frequently, such as the living room orlounge.
- Avoid placing the Room Thermostat in areas with aircirculation, near heating/cooling units, or spots that receivedirect sunlight.
- Mount the Room Thermostat on the wall using the provided dowelsand screws.
- Place the Receiver in a location that avoids physical contactwith the heating unit and protects it against liquid and dust.
- Ensure that the Receiver is not mounted on metal surfaces,close to electrical cables and electronic equipment, or near largemetal structures or other buildings.
- Connect the Receiver to the heating/cooling unit using theprovided cables.
Programming
The HT300S RF allows for daily and weekly programming. Follow the steps
below to program the thermostat:
- Press the Weekly Program Button on the Room Thermostat.
- Use the Temperature Adjustment Buttons to set the desiredtemperature for each day of the week.
- Press the Mode Button to switch between Comfort, Economy, andHoliday modes.
- Use the Temperature Adjustment Buttons to adjust thetemperature within each mode.
- Press the Weekly Program Button again to save the programmedsettings.
Calibration
The HT300S RF allows for heating calibration. Follow the steps below to
calibrate the thermostat:
- Press the Heating & Cooling Option on the RoomThermostat.
- Use the Temperature Adjustment Buttons to increase or decreasethe temperature calibration value.
- Press the Heating & Cooling Option again to save thecalibration settings.
Manual Operation
The HT300S RF allows for manual operation of the heating/cooling unit.
Follow the steps below to activate manual operation:
- Press the Manual Operation Button on the Receiver.
- Use the heating/cooling unit manually as desired.
- Press the Manual Operation Button again to deactivate manualoperation and return to normal operation mode.
Pairing
The HT300S RF requires pairing between the Room Thermostat and the Receiver.
Follow the steps below to pair the devices:
- Ensure that both the Room Thermostat and Receiver are poweredon.
- Press the Pairing Button on the Receiver to enter pairingmode.
- Press any button on the Room Thermostat to initiate the pairingprocess.
- The devices will automatically pair and establish a wireless connection.
Troubleshooting
If you are experiencing any issues with the HT300S RF, refer to the FAQ section below for common troubleshooting steps.
GENERAL SPECIFICATIONS
HT300S RF is a wireless room thermostat. The user can get more comfortable and economical heating by adjusting the room thermostat to the required temperature.
- Daily and Weekly Programming
- Different Mode Options (Comfort, Economy, Holiday)
- Heating Calibration
- TPI Algorithm
- ON/OFF Control Wireless Connection
- Precise Temperature Measurement
HT300S RF and equipments
TECHNICAL DATA
Room Thermostat
Dimensions | 85mm / 125mm / 20mm |
---|---|
Operating Current | 3V DC (2 x AAA alkaline battery) |
Temperature Measurement Accuracy | 0.1oC |
Operating Temperature Range | (5oC) – (30oC) |
Battery Life | 1 Year (2 x AAA) |
Operating Temperature | (-10oC) – (+50oC) |
Storage Temperature | (-20oC) – (+60oC) |
Receiver
Dimensions | 90mm / 90mm / 25mm |
---|---|
Operating Current | 230V AC |
Relay NO Switching Current | 7A (240VAC – Resistive Load) |
10A (120VAC – Resistive Load)
Storage Temperature| (-20oC) – (+60oC)
ROOM THERMOSTAT Button Functions
1 | Weekly Program Button |
---|---|
2 | Temperature Adjustment Button (To Increase) |
3 | Heating & Cooling Option |
4 | Temperature Adjustment Button (To Decrease) |
5 | Mode Button |
6 | On/Off Button – Unlock Button |
Product Display Layout
RECEIVER
- Manual Operation Button: Deactivates the Receiver and allows you to use the heating/cooling unit manually.
- Pairing Button: Allows pairing the Receiver with the Room Thermostat.
- Receiver LED Light
- Receiver Power Cable Input
- Heating/Cooling Unit Connection Cable Input
RECEIVER LED DESCRIPTIONS
Steady Red| The receiver has power but Receiver and Room Thermostat
are not paired.
---|---
Blinking Green| Waiting for pairing signal from the Room Thermostat.
Steady Green| The receiver and Room Thermostat are paired.
The heating/cooling unit is not operating.
3 Short Orange Blinking| Operate the heating/cooling unit signal has reached to
the Receiver.
Steady Orange| The heating/cooling unit is operating.
3 Short Green Blinking| Shut the heating/cooling unit down signal has reached
to the Receiver.
Blinking Orange| The heating/Cooling unit operates in manual mode.
Blinking Red| The receiver did not get any signal from the Room Thermostat for
22 minutes or longer.
The heating/cooling unit has shut down.
ROOM THERMOSTAT PLACEMENT
Room Thermostat needs to be placed in the room which is used most frequently.
For instance; the living room or lounge. Placing the Room Thermostat in a spot
that has air circulation like the entrance of a room or the side of a window
should be avoided. Also anywhere close to heating/cooling units such as
radiator, stove, and spots which get direct sun lights would not be suitable.
Room Thermostat needs to be located above the floor 150 cm height.
BATTERY PLACEMENT
Press the screwdriver forward from the space at the bottom of the Room Thermostat, bend the tabs, and separate the front cover. Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Replace both batteries at the same time. Align the front part of your Room Thermostat with the corresponding slot on the back, and then push gently until the thermostat snaps into place.
Low Battery Warning: When the “ ” icon appears on the screen, it means
“low battery warning”. It is recommended to replace the batteries when this
warning appears.
Warning: When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that may occur would be out of
warranty. Please throw your dead batteries into the waste bin for batteries.
RECEIVER PLACEMENT
The important things to note for the Receiver placement are avoiding physical contact between the Receiver and heating unit, and protecting it against materials such as liquid, dust etc.
The devices should be placed to minimize the damage to the received and transmitted signals by paying attention to the following points;
- The devices should not be mounted on metal surfaces.
- The devices should not be installed close to electrical cables and electronic equipment such as computers and television units.
- The devices should not be installed near large metal structures or other building materials using fine metal meshes such as special glass or special concrete.
- Distance between the Room Thermostat and the Receiver should not exceed 20 meters or 2 floors.
- The receiver must be installed at least 50 cm away from the heating/cooling unit.
RECEIVER SETUP
- First, shut down your heating/cooling unit and your heating/cooling unit’s power source with all electrical current (fuse, socket etc.)
- As shown in the connection diagram, connect one end of the heating/cooling unit connection cable to the COM and the other to the NO input of the Receiver.
- Connect the other ends of the cable -which you connected to the Receiver- to the room thermostat connection terminal as shown in your heating/cooling unit’s user manual.
- You must first connect the Receiver power cable to the Receiver and then to the fuse to which the heating/cooling unit is connected.
- After completing the cable connection process, firstly turn on your fuse and then your heating/cooling unit.
- By pressing the Receiver’s manual usage button for 2 seconds, you should see the Orange Light blinking on the Receiver. In this way, after making sure that the heating/cooling unit is operating, press the same button again for 2 seconds and see that the range LED turns off.
- Set up the Room Thermostat to pair the Receiver with the Room Thermostat.
RECEIVER WIRING DIAGRAM
Warning: Operations within the heating unit or the electrical installation must be carried out by professionally qualified persons.
PAIRING THE ROOM THERMOSTAT AND THE RECEIVER
- Primarily press the sync button of the Receiver for 2 seconds and see the blinking green light of the Receiver.
- While your device is turned off, press and hold the “On/Off” button for 3 seconds.
- Press the button until the “ ” menu appears.
- Press the “Up” or “Down” button of your Room Thermostat while the LED is flashing green.
- If the pairing is successful, the green flashing LED on the Receiver will be steady.
- The receiver and Room Thermostat have been paired to each other.
ROOM THERMOSTAT TEMPERATURE CALIBRATION
Temperature sensors that are used in Room Thermostats are highly sensitive.
You may need to calibrate your Room Thermostat if you would like to get the
same temperature values as other thermometers in your living space.
- While your device is turned off, press and hold the “On/Off“ button for 3 seconds. Press the “On/Off” button until the “ ” menu appears. To see the desired temperature, set the temperature difference by pressing the “Temperature Adjustment Buttons”. This value can be arranged between “-8° C” and “+8° C”.
- In order to save the settings and exit, press the “On/Off” button until the device turns off.
Note: Recommended temperature calibration is “0.0°C”.
FACTORY SETTINGS RESET
You can reset your Room Thermostat to its default factory settings. This
operation resets the mode temperature values, calibration setting, and
heating/cooling modes settings to factory setting. To reset your Room
Thermostat to factory setting:
- While your device is turned off, press and hold the “On/Off” button for 3 seconds.
- Press the “On/Off” button until the “ ” menu appears.
- While in the “ ” menu, select the “ ” option by using the “Up” or “Down” buttons and press the “On/Off” button.
- Your device will be turned off and reset to factory settings
KEY LOCK
- In the Room Thermostat, there is a key lock function to avoid any unintended contact.
- To unlock the Room Thermostat’s key lock the “On/Off” button should be pressed for 3 seconds. If buttons on the Room Thermostat are not touched for 10 seconds, the key lock will be reactivated.
DAY AND HOUR SETTINGS
- While your Room Thermostat is on, keep pressing the “Weekly Program” button for 3 seconds.
- At the first screen that appears, the hour part will be blinking. You may set the time with the “Up” and “Down” buttons.
- After setting the time, the “Heating & Cooling Option” button needs to be pressed once. For the minute setting, the minute part will be blinking. You may set the minute with the “Up” and “Down” buttons.
- After setting the minute, the “Heating & Cooling Option” button needs to be pressed once to set the day of the week.
- Monday has been set as the first day of the week and indicated with the number “1″.
- Numbers indicate the following days respectively 2-Tuesday, 3-Wednesday, 4-Thursday, 5-Friday, 6-Saturday and 7-Sunday
- When the setting is done, you may exit by pressing the “Weekly Program” button for 3 seconds.
MODE SETTING
Your Room Thermostat has 5 different modes. 3 of them (Comfort, Economy, and
Holiday Mode) are preset modes. Other modes are manual mode and weekly program
mode.
In preset modes, temperature values are based on the user’s choices which have
been set in the beginning. Manual mode allows the Room Thermostat to operate
within the temperature that is required and set directly by the user. Weekly
Program mode continues to work according to the weekly schedule determined by
the user.
To change the temperature values of preset modes:
-
Press and hold the “Mode” button for 3 seconds while your Room Thermostat is on.
-
Comfort Mode temperature value will appear. You may adjust the temperature value of Comfort Mode by pressing the “Up” and “Down” buttons.
-
When the setting is done, you may adjust the temperature value of Economy Mode with the “Up” and “Down” buttons by pressing the “Mode” button again.
-
You may exit the setting screen by pressing the “Mode” button for 3 seconds.
-
To change the manual mode temperature, press the “Up” or “Down” button while in the main screen. The Room Thermostat will switch to Manual
Mode once pressed the “Up” or “Down” button. -
You may press the “Mode” button to switch to the other modes
WEEKLY PROGRAM
You may set the operating schedule of your Room Thermostat with weekly program
mode. 7 different temperature values can be set for each day in weekly
programming. These values can be set in temperature adjustment screens ”
P0-P6”.
-
To set the weekly schedule, press and hold the “Weekly Program“ button for 3 seconds while your Room Thermostat is on. The “Hour, Minute, and Day” setting will appear. Press the “Heating & Cooling Option” button until the “Weekly Program” menu (P0) appears.
-
Days of the week will be blinking on the screen. You can initiate the weekly program setting if you wish to set the same schedule for every day of the week.
-
Press the “Up“ button once if you wish to set the same schedule for the weekdays. The first five days of the week will be blinking on the screen.
-
Press the “Up“ button once more if you wish to set the same schedule only for the weekend. The last two days of the week will be blinking on the screen.
-
Press the “Up“ button one more time if you wish to set the same schedule for every day of the week. 1st day of the week will be blinking on the screen. You can switch between the days by pressing the “Up“ button. Press the “Down“ button to switch to the previous day.
Press the “Weekly Program“ button once to set a schedule.
“P0” will be blinking on the screen. Set the temperature value of “P0” by pressing the “Weekly Program“ button once more. The hour setting of “P0” cannot be changed since it’s a factory setting. -
Press the “Weekly Program” button again. The day indicator will be blinking. If you will not change the day, press the “Weekly Program” button again and switch to the “P1” setting by pressing the “Up” button.
-
First, the hour setting will appear on the screen. Once you complete the hour setting, adjust the minute setting by pressing the “Weekly Program” button. After the minute setting, press the “Weekly Program” button to set the temperature value.
-
Follow the same steps for other schedule settings.
-
Once all changes are made, press and hold the “Weekly Program” button for 3 seconds to save.
Note: To check the weekly schedule which has been set without making any changes, press the “Weekly Program” button once while your Room Thermostat is on. Press the “Up” and “Down” buttons to see the days, and press the “Mode” button to see the settings between “P0-P6”.
TPI ROOM THERMOSTAT WORKING LOGIC
Your Room Thermostat works with the TPI algorithm. Room Thermostats using TPI
technology predict when the temperature of your home will rise above or below
the set temperature and turn the heating/cooling unit on and off accordingly.
This ensures that your home stays at the temperature you set without maximum
deviations up and down.
-
What is TPI?
-
TPI technology is designed to ensure that you get the best possible energy efficiency from your heating/cooling system. It measures and applies the best possible timings to deliver and maintain your home at the set temperature level.
-
How does TPI work?
Thanks to the advanced artificial intelligence technology found in the software, it adapts to the temperature change of the environment in which it is located. By creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how to maintain this temperature. In this way, it provides minimum energy consumption by calculating how long your heating/cooling unit should work for. -
What is the difference?
-
In non-TPI room thermostats, the heating/cooling unit works and stops continuously until it exceeds the set temperature value. If the set temperature drops below a certain amount, the heating/cooling unit will work again. This creates greater temperature fluctuations and less energy control. TPI Room Thermostats, on the other hand, provide higher savings and comfort compared to On/Off room thermostats with the advantages it has.
Heating Mode
Your room thermostat takes the average room temperature of the last 40 seconds
as a basis. With the TPI algorithm in the product by creating a general
temperature map of your home, it learns how long it takes to reach the desired
room temperature and how this temperature is maintained. Thus, it ensures that
the room temperature remains within a certain range.
TPI ROOM THERMOSTAT HEATING MODE WORKING GRAPHIC
TEMPERATURE (ºC) Desired Temperature TPI Room Thermostat 30
Cooling Mode
Your room thermostat takes the average room temperature of last 40 seconds as
basis. With the TPI algorithm in the product by creating a general temperature
map of your home, it learns how long it takes to reach the desired room
temperature and how this temperature is maintained. Thus, it ensures that the
room temperature remains within a certain range.
TPI ROOM THERMOSTAT COOLING MODE WORKING GRAPHIC
Your Room Thermostat sends the last status signal to the Receiver every 6 minutes. Thus, your Room Thermostat and Receiver work synchronously. If the signal cannot reach to the Receiver from the Room Thermostat for 22 minutes, it perceives that the connection is broken and stops the heating/cooling operation for safety reasons. Likewise, in cases where the electricity comes back after a power failure, the Receiver does not operate the heating/cooling unit until the ‘operate’ signal reaches the Room Thermostat. However, in this case, if the Room Thermostat continues to operate normally, it will continue to work properly without any need for intervention since it sends a status signal to the Receiver every 10 minutes.
WHAT TO KNOW ABOUT TPI ROOM THERMOSTAT
- If the placement of the TPI Room Thermostats is changed, the learning process will restart. The learning process should be considered as 7 days.
- If the TPI Room Thermostats are de-energized (battery replacement), the learning process will restart. The learning process should be considered as 7 days.
FREQUENTLY ASKED QUESTIONS
-
Is my Room Thermostat compatible with my heating/cooling unit?
If your heating/cooling unit has On-Off connections, your Room Thermostat is compatible. You can find information about your heating/cooling unit from your heating/cooling unit operating manual or from your heating/cooling unit service. -
How will I connect my heating/cooling unit with my Receiver?
We recommend that the connection between the Receiver and heating/cooling unit should be made by professionally qualified persons.
2×0.75 mm cable is sufficient for the Receiver–heating/cooling unit connection. Connect one end of the cable pair to the room thermostat connection terminals stated in the user manual of your heating/cooling unit.
Connect the other end of the cable pair to COM and NO inputs of the terminal
inside the Receiver as shown in the “RECEIVER WIRING DIAGRAM” section.
The direction of the cable ends does not matter.
DECLARATION OF CONFORMITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş. which Head Office
and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç – Gaziemir
– İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its
specifications below is covered by the provisions of the mentioned directive.
- Brand: GENERAL Life
- Product Name: HT300S RF
- Product Type: Digital Room Thermostat
Compatible Directives:
- Radio and Telecommunications Terminal Equipment Regulation 2014/53/EU (ETSI EN 301 489-1 V2.2.3 (2019-11),
- ETSI EN 301 489-17 V3.2.4 (2020-09), EN 300 220-1 V3.1.1,
- EN 300 220-2 V3.2.1 (2018-06), EN 62479: 2010, EN 62368-1:2014+A11:2017) Electromagnetic Compatibility Regulation 2014/30/EU
- (ETSI EN 301 489-1 V2.2.3, ETSI EN 301 489-3 V2.1.1)
- Low Voltage Directive 2014/35/EU (EN 60730-2-9)
Additional Information: The mentioned product can be used with heating/cooling units with On-Off output and compliance with the directives only covers the product. ISIPARK is not responsible for the entire system’s compliance with the directives. This statement is not valid if changes are made to the product without our approval.
WARRANTY CONDITIONS
- The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years.
- Devices and apparatus are delivered to the customer in working condition in our company. On-site commissioning is subject to a service fee.
- The repair of the devices and apparatus covered by the warranty is carried out in our company factory and should be sent by a contracted transportation company. In on-site services, the transportation and accommodation expenses of the service personnel belong to the customer. The shift fee during transportation is added to the service fee and collected in advance.
- The maintenance of devices and apparatus is done in our company. For the maintenance of the devices and apparatus, the round travel fares belong to the customer.
- In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault, and it is reported with a report issued by our company.
- In case of detection of manufacturer-induced errors of devices and apparatus whose warranty period continues, the customer can request a replacement or repair of the devices and apparatus at full expense by the manufacturer, unless it’s higher than the product’s price.
- If the faults of the devices and apparatus whose warranty period continues are determined as caused by the customer, all expenses would belong to the customer.
- Customers should be aware of damages (if there is any) to the product and warn the manufacturer from the day the warranty duration starts. If the customer does not warn the manufacturer with knowledge of the damage, the customer loses the rights of Article 6.
- Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty.
- Devices and their apparatus are out of warranty if they are beaten, broken, or scratched by the customer.
- Damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty.
- Battery leakage and errors due to rust, oxidation, and liquid contact by working in acidic/humid environments are not covered by the warranty.
- When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that will occur are out of warranty.
- Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. Customers can take transportation insurance.
- Damages caused by mains voltage / faulty electrical installation are not covered by the warranty.
- Devices and apparatuses are out of warranty for malfunctions caused by force majeure such as fire, flood, and earthquake, etc.
- All of the devices and apparatuses, including all their parts, are under the warranty of our company.
- In case of malfunction of the devices and apparatuses within the warranty period, the time spent during the repair period is added to the warranty period. The repair period of the product cannot exceed 20 working days. This period starts from the date of notification to the service station of the malfunction related to the product or, in the absence of a service station, to the seller, dealer, agency, representative, importer or manufacturer of the product. Consumers can report the problem by; phone, fax, e-mail, registering and replying to paid letters, or a similar way. However, in case of a conflict, the responsibility of proving belongs to the customer. If the malfunction of the product is not repaired within 20 working days, the manufacturer-producer or importer; has to allocate another product with similar features to the use of the consumer until the repair of the product is completed,
- Although the consumer uses his/her repair rights, -If the product breaks down 4 times in a year or 6 times in warranty duration and these problems affect the main purpose of the product. (Starting from delivery time during warranty.) -Exceeding the maximum time required for repair, -If the service station is not available, if it is determined that the repair of the defect is not possible with the report prepared (in order) by one of the sellers, dealer, agency, representative, importer or manufacturer, a refund or a price discount at the rate of defect can be requested.
- The customer can make complaints and appeals to consumer courts or consumer arbitration committees.
- The warranty document must be kept by the customer during the warranty period. If the document is lost, a second document will not be issued. In case of loss, repair, and replacement of devices and apparatus will be made for a fee.
WARRANTY CERTIFICATE
Manufacturer
- Title: ISIPARK İÇ DIŞ TİC. A.Ş.
- Address: Fatih Mah. 1188 Sk. No:13/A Sarnıç
- Gaziemir İzmir-TÜRKİYE
- Tel: + 90 (232) 457 99 50
- Fax: +90 (232) 457 91 22
- E-Mail: generallife@generallife.com.tr
Authorised Signatory:
Company Stamp:
Product
- Type: Digital Room Thermostat
- Brand: GENERAL Life
- Model : HT300S RF
- Guarantee Period: 5 Years
- Max. Time to Repair : 20 Days
- Banderole and Serial Number
FAQ
- Q: How do I change the batteries in the Room Thermostat?
- A: Refer to the user manual for instructions on battery placement for the Room Thermostat.
- Q: What should I do if the heating unit is not working?
- A: Check if the Heating Indicator on the Receiver is blinking. If it is steady, the heating unit is not working. Ensure that the heating unit is properly connected and powered on. If the issue persists, consult a professional technician.
- Q: Can I program different temperatures for different days of the week?
- A: Yes, the HT300S RF allows for daily and weekly programming. Use the Weekly Program Button and Temperature Adjustment Buttons on the Room Thermostat to set different temperatures for each day of the week.
- Q: How do I activate the manual operation of the heating/cooling unit?
- A: Press the Manual Operation Button on the Receiver to activate the manual operation. Use the heating/cooling unit manually as desired. Press the Manual Operation Button again to deactivate manual operation and return to normal operation mode.
- Q: How do I pair the Room Thermostat with the Receiver?
- A: Ensure that both the Room Thermostat and Receiver are powered on. Press the Pairing Button on the Receiver to enter pairing mode, then press any button on the Room Thermostat to initiate the pairing process. The devices will automatically pair and establish a wireless connection.
Isıpark reserves the right to change product specifications and user manuals.