dji T20P Intelligent Charger User Guide

June 3, 2024
DJi

T40/T20P
Intelligent Charger
User Guide

Disclaimer

Congratulations on purchasing your new DJITM product. Read this entire document and all safe and lawful practices DJI provided carefully before use. Failure to read and follow instructions and warnings may result in serious injury to yourself or others, damage to your DJI  product, or damage to other objects in the vicinity. By using this product, you hereby signify that you have read this document carefully and that you understand and agree to abide by all terms and conditions of this document and all relevant documents of this product. You agree to only use this product for proper purposes. You agree that you are solely responsible for your own conduct while using this product and for any consequences thereof. DJI accepts no liability for damage, injury, or any legal responsibility incurred directly or indirectly from the use of this product.
DJI is a trademark of SZ DJI TECHNOLOGY CO., LTD. (abbreviated as “DJI”) and its affiliated companies. Names of products, brands, etc., appearing in this document are trademarks or registered trademarks of their respective owner companies. This product and document are copyrighted by DJI with all rights reserved. No part of this
product or document shall be reproduced in any form without the prior written consent or authorization of DJI. This document and all other collateral documents are subject to change at the sole discretion of DJI. This content is subject to change without prior notice. For up-to-date product information, visit www.dji.com and go to the
product page for this product.

Warning

  1. Read these instructions carefully before use. Failure to follow the relevant instructions may result in property damage, personal injury, or death. The warnings and precautions in this manual do not cover all possible situations and the user must practice common sense in relation to the product that is not mentioned in this manual and maintain a cautious attitude.
  2. Only qualified electricians can wire the charger to three-phase AC power and they must wear insulating gloves.
  3. To use the T40 Intelligent Charger with a third-party generator, make sure to purchase a three-phase generator which has a rated voltage of 380 V and rated output of 12 kW or above. To use the T20P Intelligent Charger with a third-party generator, make sure to purchase a three-phase generator which has a rated voltage of 380 V and rated output of 6 kW or above.
  4. To disconnect or reconnect the connector between the DC module and the AC module, disconnect the charger from power supply first. DO NOT perform this operation while the charger is running.
  5. DO NOT use the charger under direct sunlight, during a thunderstorm, or in other wet environments.
  6. The charger should be kept in an environment with a temperature range of 23° to 104° F (-5° to 40° C).
  7. Keep the charger away from heat, pressure, water, flammable gases, and corrosives.
  8. Keep the charger away from inflammable materials while charging. DO NOT place the charger or charging batteries on a blanket or any carpeted surfaces when in use.
  9. Place the charger on a flat and stable surface. In order to prevent fire hazards, make sure the device is properly insulated and that there is at least 50 cm of space for ventilation.
  10. DO NOT use the charger in an area where batteries are stored. There should be a distance of at least 30 cm between the charger and any charging batteries. Otherwise, the charger or charging batteries may be damaged by excessive heating and may even lead to a fire hazard.
  11. Refer to the user guide of the batteries for more safety instructions before use.
  12. In case of fire, use a dry powder fire extinguisher. A liquid fire extinguisher may lead to an electrical hazard.
  13. DO NOT unplug the AC power cables or charging cable while the charger is in use. Remove the batteries after charging is completed.
  14. If there is any noticeable buildup on the charging cable connector, clean it up at the earliest possible opportunity. Make sure the charger is not connected to power before cleaning.
  15. DO NOT move or carry the charger by pulling the charging cable. Otherwise, the charging cable may be damaged.
  16. Handle the charging cable with care to avoid damage from strong impact.
  17. The dustproof cover should be cleaned regularly to ensure the cooling effect of the fans.
  18. Use the remote controller for DJI AGRASTM T40 or T20P to activate the chargers and update firmware. Before activation or firmware updates, make sure that the remote controller has been updated to the latest firmware.

In the Box

T40/T20P Intelligent Charger × 1| Three-Phase AC Power Cable
(Power Supply) × 1| Three-Phase AC Power Cable (Charger) × 1
---|---|---
| |
Single-Phase AC Power Cable
(Power Supply)* × 1| Single-Phase AC Power Cable (Charger) × 1
|

  • The single-phase AC power cable (power supply) is packaged in a separate box. The type of the single-phase AC power cable (power supply) may vary depending on the country or region and the illustration may differ from the actual product.

Introduction

The T40/T20P Intelligent Charger supports single-phase and three-phase AC power input and can connect with one battery. For compatible batteries, see the Specifications section.
While charging, the charger monitors the status of the battery and can automatically adjust the charging current if required. The intelligent power adjustment function ensures charging can continue even if the ventilation holes are blocked. The charger also boasts a self-diagnostics function. Users can check the status LEDs to confirm if there
are any errors. For more detailed information regarding any errors, users can connect the charger to a remote controller using a USB-C cable and launch the DJI Agras app.
Additionally, the charger includes overcurrent protection, overcharging protection, under-voltage protection, overheating protection, and status display.
The general descriptions in this user guide apply to both the T40 Intelligent Charger and the T20P Intelligent Charger. The T40 Intelligent Charger is used as an example below. The illustrations in this user guide may differ from the actual product.

Overview

1. Charging Cable 5. Cable Storage Cover
2. Status LEDs 6. AC Power Port
3. Dustproof Cover 7. Ventilation Holes
4. Handle

Status LEDs

  1. Charging Channel Status LED
  2. DC Module Status LED
  3. Generator (excl. DC Module)/AC Module Status LED
  4. USB-C Connector Cover
Status LED Blinking Pattern I- Description
Charging Channel Status LED Solid yellow The charger is ready to connect to

a battery
Blink green once continuously| Charging
Solid green| Fully charged
Blink yellow once continuously| Warning for the battery/charging channel
Blink red once continuously| Battery/charging channel error
DC Module Status LED| Blink yellow four times continuously| DC module is not activated
Blink yellow once continuously| Warning for the DC module
Blink red once continuously| DC module error
Generator (excl. DC Module)/AC Module tatus LED| Blink yellow four times continuously| Generator (excl. DC Module)/AC module is not activated
Blink yellow once continuously| Warning for the generator (excl. DC Module)/AC module
Blink red once continuously| Generator (excl. DC Module)/AC module error
Blink red four times continuously| Generator (excl. DC Module) maintenance is required

  • When the status LEDs blink for warning or error, connect the charger to the remote controller using a USB-C cable to see more information.
  • If any part of the charger is abnormal or damaged, it is recommended to contact a DJI-authorized dealer or DJI Support to repair or replace the part.

Activation
The intelligent charger must be activated before using for the first time. Connect the remote controller to the internet first. Use a USB-C cable to connect to the USB-C connector of the charger and the USB-A connector of the remote controller. Run the DJI Agras app on the remote controller and tap on the upper left corner of the
main interface to enter the charging device interface to activate the charger.

Using the Intelligent Charger

Connecting to Three-Phase AC Power

  • Strictly follow the steps described below in order.
  • Besides other electrical devices, make sure that the electrical distribution box can provide at least 12 kW of power (at least 16 A of current) for the T40 Intelligent Charger and at least 6 kW of power (at least 16 A of current) for the T20P Intelligent Charger. If you need to connect the charger to a third- party three-phase generator, make sure that the output power of the three-phase generator also meets the corresponding requirements.
  1. Turn off the air circuit breaker for the three-phase AC power supply.

  2. Rotate and open the cover of the three-phase AC power cable (power supply) and connect the two three- phase AC power cables. Connect the three-phase AC power Cable (charger) to the AC power port of the charger.

  3. Connect the intelligent charger to the three-phase AC power supply:
    Connect the three conductors (labeled L1, L2, L3) of the three-phase AC power cable (power supply) to the three hot terminals of the air circuit breaker and the one ground wire (labeled PE) to a grounding terminal of the electrical distribution box.
    •  Only qualified electricians can wire the charger to three-phase AC power and they must wear insulating gloves.
    •  DO NOT connect the ground wire to a neutral terminal or hot terminal.

  4. Turn on the air circuit breaker of the three-phase AC power supply.

  5. Connect the charger to the battery.
    • If using Agras T40, connect the charging cable to the air-cooled heat sink before putting the battery into the heat sink. The charger starts to charge the battery. The four LEDs of the battery blink in sequence while charging. Remove the battery when the four LEDs turn solid or off and put another battery inside the heat sink to charge.
    • If using Agras T20P, connect the charging cable to the battery directly. The charger starts to charge the battery. The four LEDs of the battery blink in sequence while charging. Remove the battery when the four LEDs turn solid or off and connect another battery to charge.

  6. When charging is finished, turn off the air circuit breaker before disconnecting the three-phase AC power cable from the charger.

Connecting to Single-Phase AC Power

  1. Connect the two single-phase AC power cables. Connect the single-phase AC power cable (charger) to the charger and then connect the single-phase AC power cable (power supply) to a power outlet.
    • The type of the power outlet may vary depending on the country or region. Choose the appropriate power outlet accordingly.
    • The power outlet should provide at least 16 A of current.

  2. Connect the charger to the battery following the same method described in the Connecting to Three-Phase AC Power section.

  3. When charging is finished, disconnect the AC power cable from the power outlet and then disconnect the AC power cable from the charger.

Updating Firmware

There will be notifications when firmware updates are available on the DJI website. Pay attention to the Download page of the product on the DJI website to get the latest firmware. Follow the instructions below to update the firmware of the charger using the remote controller.

  1. Connect the remote controller to the internet and then connect the charger to the remote controller using a USB-C cable.
  2. Run the DJI Agras app on the remote controller and update the firmware by following the instructions.

Storage and Maintenance

Storage
When you are not using the charger, disconnect the charger from AC power and disconnect the charging cable from the battery. Place the charger in a stable place.

  • DO NOT place the charger under direct sunlight or in rain or other wet environments.
  • Keep the charger away from heat, pressure, water, flammable gases, and corrosives.

Maintenance
Clean the dustproof cover regularly to ensure the heat dissipation performance.

  1. Remove the four screws and remove the dustproof cover.
  2. Clean the dustproof cover and install it back in place. Install the four screws to secure the dustproof cover.

Specifications

Item T40 Intelligent Charger T2OP Intelligent Charger
Model Number CSX602-9500 CSX602-4500
Operating Temperature -5° to 40° C (23° to 104° F) -5° to 40° C (23° to 104°

F)
Output Channel| 1| 1
Input/Output| Input: 3 Phase 380-420 VAC, 50/60 Hz, 16 A MAX Output: 59.92 VDC, 150 A MAX
Input: 1 Phase 220-240 VAC, 50/60 Hz, 16 A MAX Output: 59.92 VDC, 50 A MAX| Input: 3 Phase 380-420 VAC, 50/60 Hz, 16 A MAX Output: 59.92 VDC, 70 A MAX
Input: 1 Phase 220-240 VAC, 50/60 Hz, 16 A MAX Output: 59.92 VDC, 46 A MAX
Compatible Battery| T40/130/T2OP Intelligent Flight Battery| T40/T30/T2OP Intelligent Flight Battery
,
Dimensions| 400 x266x 120 mm| 318.5x254x108 mm
Weight| Approx. 12.7 kg| Approx. 8.8 kg

WE ARE HERE FOR YOU

| |
---|---|---
https://www.dji.com/support| https://www.facebook.com/qr/901489424133812| https://www.youtube.com/c/DJIAgriculture

For the latest information on Agras products, scan the Facebook or YouTube QR code.
Download the latest version from
www.dji.com/t20p/downloads or www.dji.com/t40/downloads

This content is subject to change.
If you have any questions about this document, please contact DJI by
sending a message to [email protected]
and AGRAS are trademarks of DJI.
Copyright © 2022 DJI All Rights Reserved.

Documents / Resources

| dji T20P Intelligent Charger [pdf] User Guide
T40, T20P, T20P Intelligent Charger, T20P, Intelligent Charger, Charger
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>