INSTALLATION
The SA-201 is a smoke detector set for discovery of fire in the first stage. If smoke develops, the SA-201 will give a loud beep of at least 85dB (A). As part of the link function all the smoke alarms within range will sound the alarm. We advice to test the smoke detectors weekly using the test button on the detectors. Save this manual in a safe place or inside of the electricity meter cupboard.
RECOMMENDED INSTALLATION LOCATIONS FOR THE SA-201
- Install the first smoke detector near the bedroom. Ensure that it is placed so, if it would detect fire, at least one exit route would still be accessible. We recommend to place one alarm near each potential blockade of your exit route, so you are alerted before a fire would block off escape.
- Use multiple smoke detectors to increase safety and ensure an alert before the escape route is blocked.
- Install at least one smoke detector on each floor of your house.
- Install at least one smoke detector in each room where people smoke or where there is equipment that may potentially cause a fire.
- Smoke and heat will first move upwards towards the ceiling; after that the smoke and heat will travel horizontally.
- Install the detector on the ceiling. Except for rooms smaller than 1m, you should stay at least 50 cm away from the wall and 61cm from any corner. Smoke and heat do not gather in such corners, preventing the detector from alerting you on time.
DO NOT INSTALL IN THE FOLLOWING LOCATIONS:
- In the kitchen; Steam from cooking might give a false alarm.
- In the shower or bathroom; water dampness might cause a false alarm and the moist environment might damage the detector.
- The garage: The car exhaust might cause a false alarm.
- In front of a fan or nearby the exhaust of an air conditioner or heater.
- In a ceiling nook.
- In rooms where the temperature could reach below -10°C or beyond 40°C.
- Do not paint or otherwise cover this smoke detector.
INSTALLATION INFORMATION:
Attach the ceiling plate using the included plugs and screws to the ceiling at
a location of your choice. Wall mounting is not recommended for smoke
detection. Then put the detector on the ceiling plate and, twist it clockwise
to lock it in place. Perform the first test by holding the key for two
seconds. Also see the paragraph: “Testing”.
USING, TESTING AND MAINTENANCE
Using
The smoke detector works if it has been mounted to the ceiling. The red LED
will now flash every 300-to-350 seconds. Once smoke is detected, the alarm
will sound. Once the smoke disappears, the smoke alarm will stop
automatically.
Time-out function:
This function will deactivate the alarm for about 10 minutes. This function
can be enabled by pushing the HUSH/TEST button very shortly. The LED will now
blink once every 10 seconds to indicate the deactivated smoke alarm.
After 10 minutes, the alarm will be fully active once again. If there is
(still) any smoke in the environment, the alarm will go off again.
This function can be used repeatedly.
Test:
Hold the button for at least 2 seconds. The operation is still correct if you
hear 2 or three signal tones. Check the smoke detectors weekly. In alarm
status the smoke detector will generate about 85dB(A). Do not use candles,
open fire or cigarettes to test the smoke detector.
Memory function:
When the alarm is triggered, the smoke detector LED will flash green every 45
seconds or so and will emit short beeps. This way you will know that the alarm
has gone off when you are away. Briefly press the test button to confirm the
message and return to standard operation
ATTENTION:
- If the cause of an alarm is unclear, assume it’s caused by fire. Immediately evacuate the building.
- Keep the smoke detectors out of the range of children.
- Protect against dust during renovations. Without protection, the smoke detectors will lose their functionality.
Maintenance:
- The smoke detector is maintenance-free. In very dusty rooms they may be cleaned by vacuum.
PLAN AN ESCAPE ROUTE:
- Make a map and mark all locations of doors and windows and a possible escape route. Note that you may need an escape ladder on high floors.
- Ensure everyone in the house knows the sound the smoke alarms produce and regularly practice use of the escape route.
- Leave the house immediately according to the plan when hearing the alarm. Every second counts: so respond quickly. If you do not notice smoke or heat, check if everyone in the house is in a secure location.
- Do not open any doors without feeling wether the door is warm or if there is smoke coming from underneath the doors. If it is, do not open that door. If the door is cold, put your shoulder firmly against the door and open it a small amount to check for any heat or smoke first.
- If there is much smoke, keep low and take shallow breaths, preferably through a moist towel. Call the fire department as soon as you are safe outside.
REPLACING THE BATTERIES:
- The detector is supplied using a built-in lithium battery. Under normal conditions the battery will last at least ten years. If the detector is about to need replacement, the smoke detector will make a chirping sound every 30 to 40 seconds for at least 30 days. If the smoke detector does not function, please contact your supplier.
ENVIRONMENT:
- Do not throw away used batteries, but recycle them using your local chemical depot. Product may not be thrown out as normal waste, but must be recycled as electrical waste.
DECLARATION OF PERFORMANCE:
- You can find it on our website:
- http://DOC.hesdo.com/SA-201_DOP_1.pdf
Photoelectric Smoke Alarm Device
20 1008
1008-CPR-MC 69265305
DOP nr.: SA-201_DOP_1 EN14604 : 2005 / AC: 2008
SA-201 made in China
Hesdo b.v. Aziëlaan 12
5232 BA ‘S-Hertogenbosch The Netherlands
(+31) (0)73 6411 355
Fire detection in buildings
Essential characteristic 1: Pass Essential characteristic 2: Pass Essential characteristic 3: Pass Essential characteristic 4: Pass Essential characteristic 5: Pass Essential characteristic 6: Pass Essential characteristic 7: Pass Essential characteristic 8: Pass
Mounting type | Ceiling |
---|---|
Main power source | Batteries, lithium, built-in |
Autonomy | At least: 10 years |
Interconnectible device | No |
Suitable for installation in a recreational vehicle | No |
Individual alarm indicator | Yes |
Alarm prevention facility | Yes |