MI-HEAT MST1 Room Thermostat for Underfloor Heating User Manual

June 3, 2024
MI-HEAT

MI-HEAT MST1 Room Thermostat for Underfloor Heating

MI-HEAT-MST1-Room-Thermostat-for-Underfloor-Heating-
product

Range of application

The MST1 thermostat can be used to control floor heating systems such as electric heating mats or heating films, as well as for NC control valves (normally closed) for water-guided floor heating systems. But other electrical heating devices such as infrared radiant heaters or convectors can also be operated via the thermostat.
IMPORTANT!: The unit only has the external temperature sensor. This must therefore be connected for operation.

Important notes

  • We recommend leaving the installation of the temperature controller and the heating system to specialists.
  • Only qualified electricians should carry out the electrical connections and the mains connection of the appliance.
  • Disconnect the cables from the power supply before installing, checking or replacing a thermostat.
  • The wiring diagram and installation instructions for the appliance can be found in this manual.
  • The manufacturer’s warranty does not cover malfunctions of the appliance that occur as a result of mechanical damage, incorrect installation, improper handling and use for purposes or conditions not specified in these installation and use instructions.

Safety instructions

Disconnect the cables from the power supply before installing, checking or replacing a thermostat. Work on electrical connections and the mains connection of the appliance may only be carried out by qualified electricians. Failure to do so will invalidate the warranty. Only plastic flush-mounted boxes may be used for thermostat installation. During installation of the corrugated pipe and again before laying the screed, make sure that the sensor can be laid in the corrugated pipe and removed again.

Technical data

Voltage 230 VAC, 50-60 Hz
Max. Switching capacity 16A
Power consumption <1 W
Weight 150g
Dimensions 80x80x38mm
IP protection IP20
Ambient temperature range -5 to +50°C
Temperature setting range +5 to +45°C
Switching differential ± 0,5K
Colour Weiß
Floor Sensor R25°C NTC, 10kOhm

Wiring diagramm

Assembly

Thermostat placement: Place the thermostat on the wall up to a height of 80 to 150cm. In locations with increased humidity, install the thermostat as far as possible from the sources of humidity according to the applicable standards. Do not place the thermostat on a wall exposed to sunlight or on the outside wall of the building. Install the floor temperature sensor at least 50cm into the heating surface and always in the installation pipe (so-called corrugated pipe), which is covered at the end to prevent building material from entering the pipe.

installation

Sensor installation

We recommend installing the floor sensor in a corrugated tube (Ø 16mm – Fig.

  1. so that it can be easily replaced in the event of a fault.
    For information on how to install the floor sensor on your heater, please refer to the installation and operating instructions of your heating mat.

Thermostat installation

Turn the control knob (fig. 2) to minimum temperature (OFF) and lever it off with a screwdriver (fig. 3). This is done in the direction away from the thermostat cover. Loosen the left screw and remove the thermostat cover and the inner frame (fig. 4). MI-HEAT-MST1-Room-Thermostat-for-Underfloor-
Heating-fig 3

Temperature setting

The thermostat can be set in the temperature range +5 ~ 45°C. When used with underfloor heating, the temperature must be limited and must not exceed the temperature specified by the manufacturer of the floor covering (usually max. 27°C). The locking mechanism is located under the control knob. With its setting, unintentional temperature changes can be avoided (e.g.: by children, hotel guests, etc.). By loosening the small screw on the right and adjusting the limiting discs, the temperature scale can be locked (e.g. between 20°C and 25°C). The red limiting disc indicates the maximum temperature, the green limiting disc the minimum temperature. If the floor temperature is lower than the temperature set on the thermostat, the LED display indicates the switching of the thermostat relays. As soon as the temperature is reached, the relays switch off and the LED display goes out.

Disposal note

  • Do not dispose of this appliance in household waste! Electronic devices must be disposed of in accordance with the Waste Electrical and Electronic Equipment Directive via the local collection points for waste electronic equipment.

Note on conformity

The CE mark is an over-the-counter mark that is addressed exclusively to the authorities and does not imply any assurance of properties.

Documentation © 2022 Mi-Heat Heizsysteme GmbH
All rights reserved. No part of this manual may be reproduced or duplicated in any form without the written consent of the publisher. It is possible that this manual contains typographical defects or printing errors. We accept no liability for errors of a technical or printing nature and their consequences.

Mi-Heat Heizsysteme GmbH
Ol Streek 39a
26607 Aurich
Germany
Internet: mi-heat.com
E-Mail: info@infrarot-fussboden.de

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals