MI-HEAT E51 Thermostat
Range of application
The E51 thermostat can be used to control floor heating systems such as electric heating mats or heating foils, as well as for NC control valves (normally closed) for water-guided floor heating systems. Via the weekly programme, the thermostat ensures that the desired temperature is available at the desired time.
Important Notes
- We recommend leaving the installation of the temperature controller and the heating system to specialists.
- Only qualified electricians should carry out the electrical connections and the mains connection of the appliance.
- Disconnect the cables from the power supply before installing, checking or replacing a thermostat.
- The wiring diagram and installation instructions for the unit can be found in this manual.
- The manufacturer’s warranty does not cover malfunctions of the appliance that occur as a result of mechanical damage, faulty installation, improper handling and use for purposes or under conditions not specified in these instructions for installation and use.
Control and settings
Display layout
Function symbols
Events
Other
Functional description
-
MODE „Antifreeze“
If you do not use the room for a long time in winter, it is recommended to activate the “Frost protection” mode to avoid building damage. -
MODE „Hold temperature“
The thermostat maintains the temperature set for the room. Do not set the floor temperature higher than the maximum temperature specified by the floor covering manufacturer. -
MODE „Program“
The thermostat maintains the temperature set for the room. Do not set the floor temperature higher than the maximum temperature specified by the floor covering manufacturer.
Safety instructions
Disconnect the cables from the power supply before installing, checking or
replacing a thermostat. Work on electrical connections and the mains
connection of the appliance may only be carried out by qualified electricians.
Failure to do so will invalidate the warranty. Only plastic flush-mounted
boxes may be used for thermostat installation. During the installation of the
corrugated pipe and again before laying the screed, make sure that the sensor
can be placed in the corrugated pipe and removed again.
Attention!
The floor sensor functions as a temperature limiter. The max. the temperature
must be set in the “Advanced settings” (see page 13). Recommended settings:
- Max. Temperature tile floor: + 45 ° C
- Max. Temperature wood, laminate floor: + 27 ° C
- Max. Temperature vinyl, PVC flooring: the maximum temperature specified by the flooring manufacturer must be set.
Factory settings
Technical data
- Voltage 230 VAC, 50-60 Hz
- Max. Switching capacity 16A
- Power consumption 2 W
- Weight 150g
- Dimensions 86x90x43mm
- IP protection IP20
- Ambient temperature range +5 bis +50°C
- Temperature setting range +5 bis +90°C
- Color Weiß
- Floor Sensor R25°C 10kOhm
Circuit diagram
Set day and time (adjust day and time)
Lock / unlock thermostat operation
Hold temperature” mode (set holding temperature)
Change operating mode (select mode)
Programme mode (set time and temperature) – part 1
Programme mode (set time and temperature) – part 2
Personal settings
Make a note of the settings you have made here.
Sensor error indications
Dimensions
Installation
Sensor installation
We recommend installing the floor sensor in a corrugated tube (Ø 16mm – see
picture) in order to be able to replace it easily in the event of a fault. For
information on how to install the floor sensor on your heater, please read the
installation and operating instructions for your heating mat.
Thermostat installation
Advanced settings
Disposal note
Do not dispose of this appliance in household waste! Electronic devices must be disposed of in accordance with the Waste Electrical and Electronic Equipment Directive via the local collection points for waste electronic equipment.
Note on conformity
The CE mark is an over-the-counter mark that is addressed exclusively to the
authorities and does not imply any assurance of properties.
Documentation © 2022 Mi-Heat Heizsysteme GmbH
All rights reserved. No part of this manual may be reproduced or duplicated in
any form without the written consent of the publisher. It is possible that
this manual contains typographical defects or printing errors. We accept no
liability for errors of a technical or printing nature and their consequences.
Mi-Heat Heizsysteme GmbH
Ol Streek 39a
26607 Aurich
Germany
Internet: mi-heat.com
E-Mail: info@infrarot-fussboden.de
References
- fussboden.de - This website is for sale! - Fussboden,belag Resources and Information.
- Mi-Heat | Elektrische Fußbodenheizung & Infrarot Heizung
- Mi-Heat | Elektrische Fußbodenheizung & Infrarot Heizung
- Mi-Heat | Elektrische Fußbodenheizung & Infrarot Heizung
- Mi-Heat | Elektrische Fußbodenheizung & Infrarot Heizung
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>