HOMEWORKS HRST-PRO-N Sunnata LED+ RF Dimmer Instruction Manual
- June 3, 2024
- HOMEWORKS
Table of Contents
HOMEWORKS HRST-PRO-N Sunnata LED+ RF Dimmer
How-to videos
Find the right LED Help
Use our mobile friendly self-paced installation tool:
www.lutron.com/wiringwizard
Find more product information:
www.lutron.com/support
- Videos
- Frequently Asked Questions
- Online Chat (8 am – 5 pm EST)
Call us:
U.S.A. | Canada | Caribbean
1.844.LUTRON1 (588.7661) (24/7)
Mexico +1.888.235.2910
Others +1.610.282.3800
Limited Warranty:
www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
For FCC/IC information:
Please visit: www.lutron.com/fcc-ic
)Lutron, Lutron, Sunnata, Claro, FASS, LED+, Pico, HomeWorks, and Satin Colors
are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the
US and/or other countries.
App Store is a service mark of Apple Inc., registered in the U.S. and other
countries.
All product names, logos, and brands are property of their respective owners.
Turn power OFF at circuit breaker
WARNING: ELECTRIC SHOCK HAZARD.
May result in Serious Injury or Death. Turn off power at circuit breaker or
fuse before installing
Load types and operation
__
Load Type
| Minimum Load| Maximum Load| __
Neutral
| Required Phase Mode 1
---|---|---|---|---
Single Gang| End of Gang| Middle of Gang
LED| 1 bulb| 250 W| 200 W| 150 W| Required| Either
MLV
Transformer with LEDs
| __
__
See Application Note #559 (P/N 048559) at www.lutron.com
| __
__
Required
| __
Forward
ELV
Transformer with LEDs
| __
Reverse
MLV
Transformer with Halogen
| __
10 W
| 400 VA
(300 W)
| __
No Derating Required
| __
Required
| __
Forward
ELV
Transformer with Halogen
| __
10 W
| __
500 W
| __
400 W
| __
300 W
| __
Required
| __
Reverse
Incandescent /
Halogen
| 10 W| 500 W| 400 W| 300 W| Required| Either
Dimmable Fluorescent
Ballast
| __
1 ballast
| 3.3 A (400 VA)| __
No Derating Required
| __
Required
| __
Forward
Hi-lume 1% 2-wire
(LTE) LED
Driver
| __
1 driver
| 3.3 A (400 W) 20 drivers
max.
| __
No Derating Required
| __
Required
| __
Forward
PHPM-PA / 3F
and GRX-TVI
| 1 interface| 3 interfaces| No Derating Required| Required| Forward
CFL| 1 bulb| 250 W| 200 W| 150 W| Required| Forward
1 See Section 7 on page 2 of this guide for phase-select instructions.
Note: For dimming MLV fixtures, the maximum lamp wattage is typically 70%-85% of the transformer’s VA rating. For actual transformer efficiency, contact the manufacturer. The total VA rating of the transformer(s) shall not exceed the VA rating of the dimmer.
IMPORTANT
- CAUTION: Use only with permanently installed fixtures with dimmable screw-in LED, dimmable self-ballasted compact fluorescent, halogen, or incandescent lamps. Use only to control the primary side of permanently installed transformer supplied low-voltage lighting, or in combination with incandescent lamps. To reduce the risk of overheating and possible damage to other equipment DO NOT use to control receptacles, fluorescent lighting fixtures, non-ballasted or externally ballasted compact fluorescent lamps, motor operated appliances or transformer supplied appliances.
- Neutral is required for all load types.
- Install in accordance with all national and local electrical codes.
- When no “grounding means” exist within the wallbox, the NEC® 2011, Article 404.9 allows a dimmer without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, twist a wire connector onto the green ground wire or remove the green ground wire on the dimmer and use an ap pro pri ate wallplate such as Claro or Satin Colors series wallplates by Lutron.
- Protect the dimmer from dust and dirt when painting or spackling the wall.
- This dimmer is not compatible with standard 3-way or 4-way switches. Use only with Lutron companion dimmers listed above.
- In any 3-way / 4-way circuit use only one dimmer with up to 4 companion dimmers.
- Maximum wire length between the dimmer and the farthest companion dimmer is 150 ft (45 m).
- Operate between 32 °F and 104 °F (0 °C and 40 °C).
- It is normal for the dimmers to feel warm to the touch during operation.
- Clean the dimmer with a soft damp cloth only. Do not use any chemical cleaners. For disinfecting, please refer to App Note #758 (048758), “Cleaning Recommendations for Lutron Products” at www.lutron.com.
- For indoor use only.
Determine wiring configuration
Fully wrap the wires around the screw and tighten (A), or strip insulated wires to 1/2 in (13 mm) and insert into the push-in terminals (B). Solid copper wire only.
OR
Mount all devices using the provided screws and attach wallplate Turn power ON at circuit breaker
Operation
Setup
Setup for use WITHOUT a system
NOTE: If setting up as part of system, phase settings and low-end trim levels
made on the dimmer will be over-written by the system software.
Adjust Low-End Trim
- Press and hold middle (LED 5) of light bar until dimmer goes to low-end and low-end setting starts to flash.
- Slide up or down on the light bar.
- Press and release Off to save and exit.
Phase-Select Mode
-
Pull out the Front Accessible Service Switch (FASS).
-
Press and hold On . Push in the Front Accessible Service Switch (FASS) and continue to hold On LED 1 and LED 9 start flashing.
LED 9 – Forward-Phase
LED 1 – Reverse-Phase (default) -
Release the On . LED 1 or LED 9 will be flashing to indicate current phase mode
-
Press and hold On to save and exit.
See the Sunnata MyLevel Personalization Application Note #734 (P/N 048734) at www.lutron.com/HWsupport for details on how to change these settings.
Setup for use WITH a system
NOTE: If setting up as part of system, phase settings and low-end trim levels
made on the dimmer will be over-written by the system software.
For use in a HomeWorks system, please refer to the Getting Started Guide:
www.lutron.com/HWsupport
For reliable performance in a system, this device should be placed within 25
ft (7.6 m) of two additional compatible HomeWorks Sunnata dimmer, switch,
keypad or HomeWorks processor wireless devices. For more information please
refer to the Wireless Setup guide: www.lutron.com/HWsupport
Troubleshooting
Symptom | Cause | Action |
---|---|---|
LED lights do not operate well or they flicker/buzz | The lamp is not | |
compatible with your Lutron dimmer | Find a compatible lamp by visiting |
Lutron’s led compatibility tool at
www.lutron.com/ledfinder
The phase is not set to the correct setting for your load type| 1. Confirm
Phase Setting for your load type. See Table in Step 2
2. Change Phase Select Mode in Step 7
The low-end is not adjusted| Perform low-end trim adjustment in Step 7
LED lights do not dim low enough| The low-end is not adjusted| Perform low-end
trim adjustment in Step 7
LEDs 1, 7 and 9 are flashing (Hot-Dimmed Wire Miswire)| Wiring error. Product
may be permanently damaged| Check wiring to be sure it matches installation
instructions and wiring diagrams
LEDs 7, 8 and 9 are flashing (Blue Screw Miswire)| Wiring error. Product may
be permanently damaged| Check wiring to be sure it matches installation
instructions and wiring diagrams
LEDs 1 and 7 are flashing (Over Voltage Protection)| The phase is not set to
the correct setting for your load type| 1. Confirm Phase Setting for your
load type. See Table in Step 2
2. Change Phase Select Mode in Step 7
Bottom three LEDs 1, 2, and 3 are flashing (Shorted FET Detection)| Wiring
error. Product may be permanently damaged| Check wiring to be sure it matches
installation instructions and wiring diagrams
Middle LED 5 is flashing (Over Temperature)| Load may exceed maximum load
rating| Ensure load does not exceed the maximum allowable load. See Table in
Step 2
Ambient temperature may exceed maximum product rating| Turn unit off until the
ambient temperature returns to the normal operating range
Unit needs to be reset| Cycle power to the unit using the Front Accessible
Service Switch (FASS) to reset
All LEDs are flashing (Over Current Protection)| The phase is not set to the
correct setting for your load type| 1. Confirm Phase Setting for your load
type. See Table in Step 2
2. Change Phase Select Mode in Step 7
Bulbs may have failed| Verify that no bulbs have failed
Wiring error. Product may be permanently damaged| Check wiring to be sure it
matches installation instructions and wiring diagrams
The dimmer may need to be reset| Cycle power to the unit using the Front
Accessible Service Switch (FASS) to reset
The lamp is not compatible with your Lutron dimmer| Find a compatible lamp by
visiting Lutron’s led compatibility tool at
www.lutron.com/ledfinder
Load is OFF and there is no LED lit on the dimmer| Power Not Present
Circuit breaker OFF or tripped Load is not installed or connected
Front Accessible Service Switch (FASS) is in the OFF position
|
Ensure breaker is On
Dimmer must have a load to operate.
Move Front Accessible Service Switch (FASS) to the ON position by pushing it in
Wiring Error
Product is not wired correctly
|
Check wiring to be sure it matches installation instructions and wiring diagrams
Light turns ON and OFF continuously| Improper load type or less than the
required minimum load| Recommended minimum load is 10 W/ 10 VA or one
compatible LED lamp listed at
www.lutron.com/ledfinder
Dimmer LED is ON but load cannot be turned on or off| Wiring error| Check
wiring to be sure it matches installation instructions and wiring diagrams
Lamps failed or not installed| Replace or install lamp
Lights don’t turn ON/OFF from a keypad or from other remote device| Improper
programming| Refer to the HomeWorks software or Lutron App to ensure proper
programming
Out of RF range| Reposition to be within 25 ft (7.6 m) of an RF signal
repeater or another RF device
FCC / IC / IFT Information
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation. Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate
this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC/ISED radiation exposure limits set forth for an uncontrolled environment. The user should avoid prolonged exposure within 7.9 in (20 cm) of the antenna, which may exceed FCC/ISED radio frequency exposure limits. This Class B digital apparatus complies with Canadian ICES-003.
References
- Lutron Support Center
- LED Compatibility Tool | Lutron
- lutron.com/fcc-ic
- Lutron Support Center
- LED Compatibility Tool | Lutron
- Lutron Support Center | Lutron
- How to Install a Dimmer Switch | Dimmer Switch Wiring | Lutron Web Tools
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>