Dimmer

Please read before installing.
Sunnata LED+ RF Dimmer
HRST-PRO-N 120 V~ 50 / 60 Hz

|
---|---
250 W  LED / CFL| 500 W Inc. / Hal. / ELV
400 VA MLV

Companion Dimmer (for 3-way wiring) HRST-RD
120 V~ 50 / 60 Hz 8.3 A

Help

HW Support Center
For additional support with installing,programming, and troubleshooting.

lutron.com/HWsupport

Find the right LED

lutron.com/LEDfinder

Use our mobile friendly self-paced installation tool: www.lutron.com/wiringwizard
Find more product information: www.lutron.com/support
– Videos
– Frequently Asked Questions
Call us: U.S.A.
1.844.LUTRON1 (588.7661) (24/7)
Mexico:  +1.888.235.2910
Others: +1.610.282.3800
www.lutron.com/support
Limited Warranty:
www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
For FCC/IC information:
Please visit: www.lutron.com/fcc-ic)Lutron, Lutron, Sunnata, Claro, Clear Connect, FASS, LED+, Pico, HomeWorks, and Satin Colors are trademarks or registered   ademarks of Lutron Electronics Co., Inc. in the US and/or other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries.
All other product names, logos, and brands are property of their respective owners.
©2022 Lutron Electronics Co., Inc.

Turn power OFF at circuit breaker

WARNING: ELECTRIC SHOCK HAZARD.
May result in Serious Injury or Death. Turn off power at circuit breaker or fuse before installing.

Load types and operation

* Maximum Allowable Load

Load Type Minimum Load Maximum Load Neutral Required Phase
Single Gang EGnadnogf MiGdadnlegof
LED 1 bulb 250 W 200 W 150 W
MLV Transformer with LEDs See Application Note #559 (P/N 048559) at
www.lutron.com Forward
ELV Transformer with LEDs Reverse
MLV Transformer with Halogen 10 W 400 VA (300 W) No Derating Required

Forward
ELV Transformer with Halogen| 10W| 500W| 400W| 300W| Reverse
Incandescent/ Halogen| 10 W| 500 W| 400 W| 300 W| Either
Dimmable Fluorescent Ballast| 1 ballast| 3.3A (400 VA)| No Derating Required| Forward
Hi-lume 1% 2 wire (LTE)  ED  Driver| 1 driver| 3.3 A (400 W)
20 drivers max.| No Derating Required| Forward
PHPM PA/3′ and GRX- TVI| 1 interface| 3 interfaces| No Derating Required| Forward

See Section 7 on page 2 of this guide for phase-select instructions.
Note: For dimming MLV fixtures, the maximum lamp wattage is typically 70%85% of the transformer’s VA rating. For actual transformer efficiency, contact emanufacturer. The total VA rating of the transformer(s) shall not exceed the VA rating of the dimmer.

IMPORTANT

  1. CAUTION: Use only with permanently installed fixtures with dimmable screw-in LED, dimmable self-ballasted compact fluorescent, halogen, or incandescent lamps. Use only to control the primary side of permanently installed transformer supplied low-voltage lighting, or in combination with incandescent lamps. To reduce the risk of overheating and possible damage to other equipment DO NOT use to control receptacles, fluorescent lighting fixtures, non-ballasted or externally ballasted compact fluorescent lamps, motor operated appliances or transformer supplied appliances.
  2. Neutral is required for all load types.
  3. Install in accordance with all national and local electrical codes.
  4. When no “grounding means” exist within the wallbox, the NEC® 2011, Article 404.9 allows a dimmer without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, twist a wire connector onto the green ground wire or remove the green ground wire on the dimmer and use an ap pro pri ate wallplate such as Claro or Satin Colors series wallplates by Lutron.
  5. Protect the dimmer from dust and dirt when painting or spackling the wall.
  6. This dimmer is not compatible with standard 3-way or 4-way switches. Use only with Lutron companion dimmers listed above.
  7. In any 3-way / 4-way circuit use only one dimmer with up to 4 companion dimmers.
  8. Maximum wire length between the dimmer and the farthest companion dimmer is 150 ft (45 m).
  9. Operate between 32 °F and 104 °F (0 °C and 40 °C).
  10. It is normal for the dimmers to feel warm to the touch during operation.
  11. Clean the dimmer with a soft damp cloth only. Do not use any chemical cleaners. For more information, please see www.lutron.com/cleaning
  12. For indoor use only.

Determine wiring configuration

Fully wrap the wires around the screw and tighten (A), or strip insulated wires to 1/2 in (13 mm) and insert into the push-in terminals (B). Solid copper wire only.

3B For lights controlled from two locations:
NOTE: Only one dimmer can be used per circuit.
NOTE: Dimmer must be wired on the load side. Connect Neutral to the dimmer. Up to four companion dimmers may be used. For additional wiring assistance go to www.lutron.com/wiringwizard

For more information please go to www.lutron.com/wiringwizard
3C For lights controlled from three or more locations:
NOTE:** Dimmer must be wired on the load side. Connect Neutral to the dimmer. Up to four companion dimmers may be used. For additional wiring assistance go to www.lutron.com/wiringwizard

Mount all devices using the provided screws and attach wallplate

Turn power ON at circuit breaker

Operation

FASS
(Front Accessible Service Switch) Pull tab out to change the room’s light bulb.
Setup
Adjust Low-End Trim (PRO-N Only)

  1. Press and hold middle (LED 5) of light bar until dimmer goes tolow-end and low-end setting starts to flash.
  2. Slide up or down on the light bar.
  3. Press and release Off to save and exit.
    Setup for use WITHOUT a system

NOTE: If setting up as part of system, phase settings and low-end trim levels made on the dimmer will be over-written by the system software.
Phase-Select Mode – Refer to Section 2 (PRO-N Only)

  1.  Pull out the Front Accessible Service Switch (FASS).

  2. Press and hold On . Push in the Front Accessible Service Switch (FASS) and continue to hold On until LED 1 and LED 9 start flashing.

  3. Release the On . LED 1 or LED 9 will be flashing to indicate current phase mode.
    LED 9 – Forward-Phase
    LED 1 – Reverse-Phase (default)

  4. Touch the light bar to select the desired phase.

  5. Press and hold On to save and exit.

See the Sunnata Dimmer MyLevel Personalization Application Note #734 (P/N 048734) at www.lutron.com/HWsupport for details on how to change these settings.
Setup for use WITH a system

NOTE: If setting up as part of system, local MyLevel changes, including phase setting and low-end trim, made locally on the dimmer will be over- written by the system  oftware.
For use in a HomeWorks system, please refer to www.lutron.com/HWsupport For reliable performance in a system, Clear Connect-Type X devices must be placed within 25 t (7.6 m) of two additional compatible Clear Connect-Type X devices. Clear Connect-Type X devices include, for example, HomeWorks Sunnata dimmer, switch, keypad and  omeWorks wireless processor/gateway devices. Companion devices are excluded from the list of compatible devices because they are not Clear Connect-Type X devices.  ompanion devices have wired communication with the main device. For more information please refer to the Wireless Setup guide: www.lutron.com/HWsupport

Troubleshooting

Symptom Cause Action

Main dimmer: LEDs 6, 8, and 9 are flashing slowly (once per second)
Some companions: LEDs 1, 2, and 4 are flashing quickly (three times per second)
Other companions: LEDs 7, 8, and 9 are flashing slowly
(once per second) or no LEDs are illuminated| One or more companion dimmer ronnertse %la% Idoea.d side of the main| 1.Str,iraepetthnezain dimmer with a companion dimmer that has LEDs 1, 2, and 4 flashing quickly
2.kepeat actiof))1re.main dimmer stops flashing LEDs 6, 8 and 9 slowly (once per second).
Main dimmer: LEDs 1,7,and 9 are flashing Companion: No LEDs illuminated| Wiring error| 1.Swap wires on black and brass terminals on main dimmer.
2.Ensure wiring matches wiring diagrams.
Main dimmer: LEDs 7, 8,and 9 are flashing Companion: No LEDs illuminated| Wiring error| 1.Swap wires on blue and brass terminals on the main dimmer.
2.Ensure wiring matches wiring diagrams.
Main dimmer: LEDs 1 and 7 are flashing Companion: No LEDs illuminated| Improper phase selection| Change to forward-phase. Confirm load compatibility in Step 2 and use instructions in Step 7/Phase-Select Mode to change phase.
Incoming line voltage is too high| Ensure that the input voltage to the dimmer is less than 130 V—.
Main dimmer: LEDs 1, 2, and 3 are flashing Companion: No LEDs illuminated| Incompatible load| Check if lamp is compatible on www.lutron.corn/ledfinder. Change to compatible lamp.
Hot and Neutral connections are reversed| Swap wires on the black and silver terminals.
Main dimmer: LED 5 is flashing Companion: No LEDs illuminateds| Load or ambient temperature exceed ratings| Ensure Vngii:irtte. within ratingsiri ZisiaiN-°1tVlieqt(Vs.fdir. multi gang applications.3.Pull FASS and replace. See Step 6.
Main dimmer: LEDs 1-9 are flashing Companion: No LEDs illuminated| A.Wiring issue at main dimmer
B.Wiring issue at load or load failure
C.Improper phase selection
D.Incompatible load| 1. Swap*. on the silver and brass terminals on the main dimmer.
i. Check at all the terminals.
4: RegovelrosadInVenlefual °arsgZinodrtin all wiring locations, including at the load. . Thaleclelitanlep   gin7paWIT)741.ttirnZon21/1aelf iunr1 nsCriact’stncompatiblest e7haraer-Select Kt mc” change Phase.
LED lights do not operate well or they flicker/b.| The phase is not set to the correct setting for your load type| Fjlie-IfiirnnsTri:gsoZVer;)Iggea_dsUgA .Voed-ertleciPag:Ppriase.
The low-end is not adjusted| Perform low-end trim adjustment in Step 7.
The lamp is not compatible with your Luton dimmer| Find a compatible lamp by visiting Lutron’s LED compatibility tool at www.lutron.com/ledfinder
LED lights do not dim low enough| The low-end is not adjusted| Perform low-end trim adjustment in Step 7.

For additional Troubleshooting, please visit www.lutron.com/HWsupport
FCC / IC / IFT Information
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and(2) This device must accept any interference, including interference that may cause undesired operation. Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radio/TV technician for help.

 This equipment complies with FCC/ISED radiation exposure limits set forth for an uncontrolled environment. The user should avoid prolonged exposure within 7.9 in (20 cm) of the antenna, which may exceed FCC/ISED radio frequency exposure limits.
This Class B digital apparatus complies with Canadian ICES-003.

MODELO: HRST-PRO-N
02132-22-10376

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals