Product description
The Window Sensor 2 detects and reports opening and closing of doors and
windows. Easily installed on any door or window, the sensor triggers a signal
when parted. This lets you know when a room is entered, if a window or a door
has been left open, etc.
The Window Sensor 2 is also available with vibration detection.
Disclaimers
CAUTION:
- Choking hazard! Keep away from children. Contains small parts.
- Please follow the guidelines thoroughly. The Window Sensor 2 is a preventive, informing device, not a guarantee or insurance that sufficient warning or protection will be
provided, or that no property damage, theft, injury, or any similar situation will take place. Develco Products cannot be held responsible in case any of the abovementioned situations occur.
Precautions
- When removing the cover for battery change – electrostatic discharge can harm electronic components inside.
- Always mount indoors as the sensor is not waterproof.
- Do not place the sensor close to magnetic or electromagnetic fields. This deviceincludes a magnet. The magnet creates a magnetic field that may cause damage to e.g. computer hard drives, magnetic cards, data storage devices, hearing aids, and speakers. Therefore, we strongly advise you to never position the magnet close to electronic devices.
Getting started
-
Open the casing of the device by pushing the fastening on top of the device to remove the front panel from the back cover.
-
Insert the enclosed batteries into the device, respecting the polarities
-
Close the casing
-
The window sensor will now start searching (up to 15 minutes) for a Zigbee network to join.
-
Make sure that the Zigbee network is open for joining devices and will accept the window sensor.
-
While the window sensor is searching for a Zigbee network to join, the yellow LED is flashing.
-
When the yellow LED stops flashing, the window sensor has successfully joined the Zigbee network.
Placement
- Place the sensor indoors at a temperature between 0-50°C.
- The magnet has to be placed on that side of the sensor which is marked with a small triangle.
- The magnet and sensor also have to be aligned/centered thickness-wise on as similar level as possible.
- For sensors with vibration, it is recommended to mount the magnet on the frame, and the sensor on the door. For sensors without vibration, it is recommended to mount the magnet on the door, and the sensor on the frame.
SEE PAGE 2 FOR ILLUSTRATIONS
Mounting
-
Clean the surface before mounting.
-
The window sensor (a) should be mounted to the frame using the double stick tape, already applied on the back of the sensor and magnet. Press firmly to secure sensor.
-
The magnet (b) should be mounted on the door or window no further than 5mm away from the arrow on the sensor.
-
There are many ways to mount the sensor and magnet, as windows and doors vary greatly. The most important consideration is for the magnet to be placed as near to the point on the sensor indicated by the grey arrow.
-
The sensor and magnet may be placed on separate three dimensional planes, though this does affect the maximum distance allowed. The magnet may also be placed either facing the side of the sensor or sitting parallel to it.
Testing
You can test if the positioning of the sensor and
magnet are correct by checking whether the
green light on the Window Sensor 2 is flashing
when you open or close the window/door.
Resetting
Resetting is needed if you want to connect your
window sensor to another gateway or if you
need to perform a factory reset to eliminate
abnormal behavior.
The reset button is marked with the small ring
on the front of the sensor.
STEPS FOR RESETTING
-
Press and hold down the reset button for approximately 14-16 seconds.
-
While you are holding the button down, the LED first flashes once, then two times in a row, and finally numerous times in a row.
-
Release the button while the LED is flashing numerous times in a row.
-
After you release the button, the LED shows one long flash, and the reset is completed.
Modes
ACTIVATION MODE
A single green flash means that the sensor and the magnet are moving either
away from or towards each other.
SEARCHING GATEWAY MODE
Yellow flashes every second for a longer period, means that the device is
searching for a gateway.
LOST CONNECTION MODE
When the yellow LED flashes 3 times, it means that the device has failed to
connect to a gateway.
LOW-BATTERY MODE
Two consecutive yellow LED flashes every 60 seconds, means that the battery
should be replaced.
Fault finding
- If the window sensor does not work when the window or door is parted, the probable cause is a faulty battery. Replace the batteries if they are worn out.
- In case of a bad or weak signal, change the location of the window sensor. Otherwise you can relocate your gateway or strengthen the signal with a smart plug.
- If the search for a gateway has timed out, a short press on the button will restart it.
Battery replacement
CAUTION:
- Do not attempt to recharge or open the batteries.
- Risk of explosion if batteries are replaced by an incorrect type.
- Dispose of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery can result in an explosion
- Leaving a battery in an extremely high temperature surrounding environment can result in an explosion or the leakage of flammable liquid or gas.
- A battery subjected to extremely low air pressure may result in an explosion or the leakage of flammable liquid or gas
- Maximum operation temperature is 50°C / 122°F
- If you experience leakage from the batteries, immediately wash your hands and/or any affected area of your body thoroughly!
CAUTION: When removing cover for battery change – Electrostatic Discharge (ESD) can harm electronic components inside
- Open the casing of the device by pushing the fastening on top of the device to remove the front panel from the back cover.
- Replace the batteries respecting the polarities. The window sensor uses 2xAAA batteries.
- Close the casing.
- Test the window sensor.
Other information
Note local regulations about information to your insurance company regarding installed window sensors.
Disposal
Dispose the product and battery properly at the end of life. This is electronic waste which should be recycled.
Placement Instructions
- The most beneficial distance between the sensor and the magnet is 0.2-0.5 cm.
- Be aware that on magnetic surface (e.g. metal door), the distance between the sensor and the magnet has to be 0.1-0.3 cm.
- The sensor and magnet should be mounted on the side opposite from the hinge/pivot point.
- Alternatively, if the sensor is placed on a window that slides open, the sensor and magnet may be mounted in many positions,
- Pay careful attention to the arrow printed on the sensor. This should be oriented to face the magnet. The distance between the two should not exceed 5mm.
Placement Examples – no vibration
- If your sensor does not detect vibration, place the sensor on the frame and the magnet on the door/window.
|
---|---
Placement Examples – with vibration
• If your sensor is a combined window and vibration sensor, it is recommended to place the sensor on the door/window and the magnet on the frame.
|
---|---
FCC statement
Changes or modifications to the equipment not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/ TV technician for help. This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
IC statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may
causeundesired operation of the device.
This equipment complies with IC RSS-102 radiation exposure limits set forth
for an uncontrolled environment. This equipment should be installed and
operated with inimum distance 20 cm between the radiator and your body.
ISED statement
Innovation, Science and Economic Development Canada ICES-003 Compliance Label:
CAN ICES-3 (B)/NMB-3(B).
CE certification
The CE mark affixed to this product confirms its compliance with the European
Directives which apply to the product and, in particular, its compliance with
the harmonized standards and specifications.
IN ACCORDANCE WITH THE DIRECTIVES
- Radio Equipment Directive (RED) 2014/53/EU
- RoHS Directive 2015/863/EU amending 2011/65/EU
Other certifications
- Zigbee 3.0 certified.
All rights reserved.
Develco Products assumes no responsibility for any errors, which may appear in
this manual. Furthermore, Develco Products reserves the right to alter the
hardware, oftware, and/ or specifications detailed herein at any time without
notice, and Develco Products does not make any commitment to update the
information contained herein. All the trademarks listed herein are owned by
their respective owners.
Distributed by Develco Products A/S
Tangen 6
8200 Aarhus N
Denmark
www.develcoproducts.com
Copyright © Develco Products A/S
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>