DEVELCO PRODUCTS F0067Z0400 Intelligent Smoke Alarm Instruction Manual
- June 12, 2024
- Develco Products
Table of Contents
DEVELCO PRODUCTS F0067Z0400 Intelligent Smoke Alarm
Product description
The Intelligent Smoke Alarm will warn occupants about smoke, using a loud
siren. While away, they will be instantly notified of apotential fire through
an internet-connected gateway.
The Intelligent Smoke Alarm will report the status and temperature every two
minutes via your IoT system.
The smoke alarm is designed for private homes, camping trailers, mobile homes
and caravans. It is not recommended for boats.
Precautions
- Do not remove the product label as it contains important information.
- Do not paint the alarm.
- Avoid placing the Intelligent Smoke Alarm in dusty rooms.
- Do not place the alarm in a kitchen, garage, or in other places where damp, gases and smoke naturally occur.
Getting started
-
Pull out the battery isolation strip as shown
a. -
The Intelligent Smoke Alarm will now start searching (up to 15 minutes) for a Zigbee network to join.
-
Make sure that the Zigbee network is open for joining devices and will accept the Intelligent Smoke Alarm.
-
While the Intelligent Smoke Alarm is searching for a Zigbee network to join, the LED button flashes red.
b. -
When the LED button stops flashing, the Intelligent Smoke Alarm has successfully joined the Zigbee network.
c.
Placement
- Place the Intelligent Smoke Alarm indoors at a temperature between 0-50*C.
- It is important to place smoke alarms in bedrooms and on exit routes.
- The distance between the smoke alarm and walls, ventilation or other obstacles, should be at least 50 cm.
- The distance between the alarm and a fireplace or stove should be at least 4 meters.
- Rooms larger than 80 m2 require several smoke alarms in order to sustain full fire safety.
- The alarm should be placed within reach for battery testing and maintenance.
- The alarm should not be placed at the top of high pointed ceilings or in ceiling corners or within 50 cm of a wall.
d. PLACEMENT EXAMPLES
RECOMMENDED LOCATION
CEILING PLACEMENT
The smoke alarm should be a minimum of 50 cm from the wall.
e. WALL PLACEMENT
** The smoke alarm should be between 30 and 50 cm from the ceiling.
f.
There should be at least one smoke alarm per floor and a maximum distance between smoke alarms of 10 meters.
g.**
Mounting
-
Detach the alarm from the mounting base by twisting counterclockwise.
-
Use the mounting base ring to mark the screw holes on the ceiling or on the wall.
h. -
Use enclosed screws and plugs to install the mounting base in the marked position.
-
If the battery is missing or inserted incorrectly, it will be impossible to attach the alarm in the mounting base.
-
Attach the alarm by twisting clockwise until it clicks.
j.
Testing
- Always test the working order of the smoke alarm after installation or battery change.
- When pressing the alarm button, the alarm sound should be heard.
- A network alarm test can be performed by holding down the alarm button for at least 6.5 seconds (count 2 sets of 3 sound sweeps). k.
- A test message will be sent over the Zigbee network.
- Test all of your alarms once a week to ensure they are functioning correctly.
Resetting
Resetting is needed it you want to connect your smoke alarm to another
gateway or if you need to perform a factory reset to eliminate abnormal
behavior.
STEPS FOR RESETTING
- Detach the alarm from the mounting base by twisting it counterclockwise.
- Press and hold the LED button.
- While you are holding the button down, the LED first flashes once, then two times in a row, and finally numerous times in a row.
- Release the button while the LED is flashing numerous times in a row.
- After you release the button, the LED shows one long flash, and the reset is completed.
L.
Modes
SEARCHING GATEWAY MODE
Red LED light in the back of the device is flashing every second (up to 15
minutes)
NORMAL MODE
Front LED is flashing every 45 seconds.
ALARM MODE
When smoke is detected, the LED will speed up flashes, and simultaneously, the
device will emit a loud alarm sound. Press the “button/top” of the alarm to
acknowledge and stop the siren. The following 10 minutes, it will block
alarms, allowing time to ventilate the smoke.
LOW BATTERY MODE
Simultaneous audible signals and front LED flashes every 45 seconds means that
the battery should be replaced.
REPLACE DEVICE MODE
When audible signals and front LED flashes are not simultaneous, the device
should be replaced. The life expectancy of smoke alarms is generally 10 years,
after which their sensors begin to lose sensitivity.
Fault finding & cleaning
- Dust particles in the smoke chamber can be removed by vacuuming the mesh.
- High humidity condensing can be resolved by drying the smoke alarm.
- If the smoke alarm does not work when the test button is pushed, the probable cause is a faulty battery. Replace the battery if it is worn out.
- In case of a bad or weak signal, change the location of the smoke alarm. Otherwise you can relocate your gateway or strengthen the signal with a smart plug.
- If the search for a gateway has timed out, a short press on the LED button will restart it.
Battery replacement
CAUTION: RISK OF EXPLOSION IF BATTERIES ARE REPLACED BY AN INCORRECT
TYPE. DISPOSE OF THE BATTERIES IN ACCORDANCE WITH INSTRUCTIONS.
CAUTION: When removing cover for battery change – Electrostatic Discharge
(ESD) can harm electronic components inside.
-
To replace the battery, detach the smoke alarm from the mounting base by twisting counter-clockwise.
-
Replace the battery respecting the polarities. The Intelligent Smoke Alarm uses 1xCR123 battery.
m. -
Attach the alarm in the mounting base by
- Zigbee 3.0 certified
All rights reserved.
Develco Products assumes no responsibility for any errors, which may appear in
this manual. Furthermore, Develco Products reserves the right to alter the
hardware, software, and/or specifications detailed herein at any time without
notice, and Develco Products does not make any commitment to update the
information contained herein. All the trademarks listed herein are owned by
their respective owners.
- Copyright © Develco Products A/S
- Distributed by Develco Products A/S
- Tangen 6 8200 Aarhus N
Denmark
www.develcoproducts.com
Smoke alarm manufactured by CAVIUS Aps Julsøvej 16
8660 Silkeborg Denmark.
Manufactured in P.R.C.
EN14604 : 2005 + AC:2008
DoP no.: F0067Z0400
The paper version of the DoP is available free of charge on request
Declared performances 4.14-4.19+5.2-5.24: Passed Dowload