Kaysun KC-FC-XT Fan Coil Thermostat Owner’s Manual

June 3, 2024
Kaysun

Kaysun KC-FC-XT Fan Coil Thermostat Owner PART NUMBER

  • KC-FC-2T:Control Motorized Valve and 3-speed fan, when the temperature reaches the set-point, it will close the Motorized Valve and Fan both
  • KC-FC-4T:Control 4 pipe fan coil units, Control two Motorized Valves and 3-speed fan, when the temperature reaches the set-point, it will close the Motorized Valves with the fan still running.
  • KC-FC-XT:Control 2 or 4 pipe fan coil units (via DIP switch), Control two Motorized Valves and 3-speed fan When the temperature reaches the set-point, it will close the Motorized Valves with the fan still running.

TECHNICAL DATA

  • Temperature Range: 10~30℃ adjustable Operating Voltage: AC220V±10%, 50/60Hz
  • Switching Differential: Approx.±1℃ Switch current rating: 1(0.5) A
  • Operating Temperature: 0~45℃ Wiring Diameter: 0.5~2.5mm2
  • Operating Humidity: 5~90%RH Dimension: 130×85×43mm(H×W×D)
  • Storage Temperature: -10~60℃ Hole pitch: 60mm

MOUNTING INSTRUCTION

Kaysun-KC-FC-XT-Fan-Coil-Thermostat-Owner-PART-
NUMBER-fig-1

OPERATION INSTRUCTION

There is temperature adjusting knob with scale mark on the front panel. There are also the Fan Speed Switch with HIGHMED- LOW and the System Switch with HEAT-OFF-COOL on the front panel. The operation steps as follows

  1. Turn On/Off: Slide the switch to HEAT when you want heating; slide the switch to COOL when you want cooling. Set the switch to OFF, the thermostat will be turned off.
  2. Set point: turn the adjusting knob to the desired temperature.
  3. Fan Speed Selection: slide the fan speed switch to any positions of HIGH-MED-LOW you wanted

WIRING DIAGRAMKaysun-KC-FC-XT-Fan-Coil-Thermostat-Owner-PART-NUMBER-
fig-2

Wire Attention

The correct model is compliant with the part number on packing label of thermostat box; Please checkout the correct model and use correct wiring diagram above when you wire

Note: Be sure to connect all the wires as per the wiring diagrams and keep it away from water, mud and other material so as to prevent the unit being spoiled