Kaysun KC-FC-XT Fan Coil Thermostat Owner’s Manual

June 3, 2024
Kaysun

Kaysun KC-FC-XT Fan Coil Thermostat Owner PART NUMBER

  • KC-FC-2T:Control Motorized Valve and 3-speed fan, when the temperature reaches the set-point, it will close the Motorized Valve and Fan both
  • KC-FC-4T:Control 4 pipe fan coil units, Control two Motorized Valves and 3-speed fan, when the temperature reaches the set-point, it will close the Motorized Valves with the fan still running.
  • KC-FC-XT:Control 2 or 4 pipe fan coil units (via DIP switch), Control two Motorized Valves and 3-speed fan When the temperature reaches the set-point, it will close the Motorized Valves with the fan still running.

TECHNICAL DATA

  • Temperature Range: 10~30℃ adjustable Operating Voltage: AC220V±10%, 50/60Hz
  • Switching Differential: Approx.±1℃ Switch current rating: 1(0.5) A
  • Operating Temperature: 0~45℃ Wiring Diameter: 0.5~2.5mm2
  • Operating Humidity: 5~90%RH Dimension: 130×85×43mm(H×W×D)
  • Storage Temperature: -10~60℃ Hole pitch: 60mm

MOUNTING INSTRUCTION

Kaysun-KC-FC-XT-Fan-Coil-Thermostat-Owner-PART-
NUMBER-fig-1

OPERATION INSTRUCTION

There is temperature adjusting knob with scale mark on the front panel. There are also the Fan Speed Switch with HIGHMED- LOW and the System Switch with HEAT-OFF-COOL on the front panel. The operation steps as follows

  1. Turn On/Off: Slide the switch to HEAT when you want heating; slide the switch to COOL when you want cooling. Set the switch to OFF, the thermostat will be turned off.
  2. Set point: turn the adjusting knob to the desired temperature.
  3. Fan Speed Selection: slide the fan speed switch to any positions of HIGH-MED-LOW you wanted

WIRING DIAGRAMKaysun-KC-FC-XT-Fan-Coil-Thermostat-Owner-PART-NUMBER-
fig-2

Wire Attention

The correct model is compliant with the part number on packing label of thermostat box; Please checkout the correct model and use correct wiring diagram above when you wire

Note: Be sure to connect all the wires as per the wiring diagrams and keep it away from water, mud and other material so as to prevent the unit being spoiled

MAIN OFFICE MADRID Blasco de Garay, 4-6 08960 Sant Just Desvern (Barcelona) Tel. +34 93 480 33 22 Senda Galiana, 1 Poligono Industrial Coslada Coslada (Madrid) Tel. +34 91 669 97 01 http://home.frigicoll.es/
http://www.kaysun.es/ Fax. +34 91 674 21 00 madrid@frigicoll.es

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals