kaysun SUITE 1×1 Split Air Conditioner User Manual

June 3, 2024
Kaysun

SUITE 1×1
RESIDENTIAL PRODUCT RANGE
2021
User Manualkaysun SUITE 1x1 Split Air Conditioner
-

PRODIGY

PRODIGY is a KAYSUN wall unit that represents a revolution in installation and preventive maintenance. Easy installation, maintenance and fitted with Kaysun avant-garde TECHNOLOGY.

kaysun SUITE 1x1 Split Air Conditioner - 1

GENERAL CHARACTERISTICS

  • SCOP 4.6, over European Directive ErP, for a high energy efficiency.
  • Louvers position memory.
  • Leakage detection system.
  • Drainage pipe connection from left or right option.
  • Self-locking option for Heating-Only function.
  • Optional MULTFUNCTION BOARD, we can control the unit with a wall controller or even connect it with a centralized controller, BMS, or external compatible controllers (Airzone…)
  • Display and buzzer switch-off to improve ambient comfort.
  • Its white translucent smart display provides user with information on the equipment and alarm systems status.
  • KID-05.1 S controller included to control unit’s work parameters and change its configuration.
  • Mono-Multi compatible.
  • Optional WIFI control adding FRIWF-USB-02.
  • K-Ion Technology: Active bipolar ionization included, we can actively help neutralize particles, bacteria, virus cells, odorous gases, aerosols and volatile organic compounds (VOCs).

OTHER CONTROLLERS

Individuals
KC-03.2 SPS| WiFi
K01-WIFI
---|---
|
Multifunction board
KMB-01| Optional WiFi
FRIWF-USB-02
|

 PRODIGY

kaysun SUITE 1x1 Split Air Conditioner - icon3

Technical Specifications

SET| AKAY-26 DR9| AKAY-35 DR9| AKAY-52 DR9| AKAY-71 DR9
---|---|---|---|---
Indoor unit| KAY-26 DR9| KAY-35 DR9| KAY-52 DR9| KAY-71 DR9
Outdoor unit| KAE-26 DR9| KAE-35 DR9| KAE-52 DR9| KAE-71 DR9


Capacity

| Cooling rated (min./max.)| kW| 2.64 (1.03 / 3.22)| 3.52 (1.38 / 4.31)| 5.28 (3.4 / 5.91)| 7.03 (2.11 / 8.21)
Heating rated (min./max.)| kW| 2.93 (0.82 / 3.37)| 3.81 (1.07 / 4.38)| 5.57 (3.11 / 5.87)| 7.33 (1.55 / 8.21)
Heating rated at -7°C| kW| TBD| TBD| TBD| TBD
Cooling input rated (min./max.)| W| 628 (90 / 1140)| 1034 (130 / 1650)| 1550 (560 / 2050)| 1500 (780 / 2000)
Heating input rated (min./max.)| W| 666 (110 / 1080)| 1027 (160 / 1560)| 2340 (420 / 3200)| 2130 (300 / 3100)
Heating input rated at -7°C| W| TBD| TBD| TBD| TBD
Energy efficiency| SEER – Energy class| 8.8 – A+++| 8.5 – A+++| 7.5 – A++| 6.5 – A++
SCOP – Energy class| 4.6 – A++| 4.6 – A++| 4 – A+| 4 – A+




Working range

| Outdoor ambient temperature for cooling min./max.| °C| -15ºC / 50ºC| -15ºC / 50ºC| -15ºC / 50ºC| -15ºC / 50ºC
Outdoor ambient temperature for heating min./max.| °C| -15ºC / 30ºC| -15ºC / 30ºC| -15ºC / 30ºC| -15ºC / 30ºC
Indoor ambient temperature for cooling min./max.| °C| 17ºC / 32ºC| 17ºC / 32ºC| 17ºC / 32ºC| 17ºC / 32ºC
Indoor ambient temperature for heating min./max.| °C| 0ºC / 30ºC| 0ºC / 30ºC| 0ºC / 30ºC| 0ºC / 30ºC
INDOOR UNIT| KAY-26 DR9| KAY-35 DR9| KAY-52 DR9| KAY-71 DR9
---|---|---|---|---
Indoor unit| Air flow low/medium/high| m³/h| 305 / 365 / 480| 327 / 414 / 531| 540 / 710 / 800| 640 / 860 / 980
Sound pressure low/medium/high| dB(A)| 24 / 29 / 36.5| 25 / 33 / 39| 32 / 39 / 43.5| 33 / 42 / 46
Sound power level| dB(A)| 53| 53| 56.5| 62
Width/height/depth| mm| 805 / 302 / 193| 805 / 302 / 193| 964 / 325 / 222| 1106 / 342 / 232
Net weight| kg| 8.7| 8.7| 11.3| 14.2
OUTDOOR UNIT| KAE-26 DR9| KAE-35 DR9| KAE-52 DR9| KAE-71 DR9
---|---|---|---|---
Outdoor unit| Compressor type| Rotary| Rotary| Rotary| Rotary
Air flow| m³/h| 2150| 2200| 2100| 3500
Sound pressure| dB(A)| 54.5| 55| 56| 60.5
Sound power level| dB(A)| 59| 61| 64| 69
Width/height/depth| mm| 765 / 555 / 303| 765 / 555 / 303| 805 / 554 / 330| 890 / 673 / 342
Net weight| kg| 26.7| 26.7| 33.5| 43.9
Power supply| V/ph/ Hz| 220-240/1/50| 220-240/1/50| 220-240/1/50| 220-240/1/50
Power wiring| mm²| (2+T)x1.5| (2+T)x1.5| (2+T)x1.5| (2+T)x2.5
Communication wiring| mm²| (4+T)x1.5| (4+T)x1.5| (4+T)x1.5| (4+T)x2.5
Refrigerant| Type refrigerant| R-32| R-32| R-32| R-32
Refrigerant charge| kg| 0.62| 0.62| 1.1| 1.45
Liquid/gas pipe diameter| inch| 1/4″ / 3/8″| 1/4″ / 3/8″| 1/4″ / 1/2″| 3/8″ / 5/8″
Piping height difference| m| 10| 10| 20| 25
Piping max. length| m| 25| 25| 30| 50

Supplementary charge: Factory pre-charge for 5 m of installation. Additional charge per metre added after 5 m.
NOTE: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.

www.kaysun.es

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals