PRODIGY
PRODIGY is a KAYSUN wall unit that represents a revolution in installation and preventive maintenance. Easy installation, maintenance and fitted with Kaysun avant-garde TECHNOLOGY.
GENERAL CHARACTERISTICS
- SCOP 4.6, over European Directive ErP, for a high energy efficiency.
- Louvers position memory.
- Leakage detection system.
- Drainage pipe connection from left or right option.
- Self-locking option for Heating-Only function.
- Optional MULTFUNCTION BOARD, we can control the unit with a wall controller or even connect it with a centralized controller, BMS, or external compatible controllers (Airzone…)
- Display and buzzer switch-off to improve ambient comfort.
- Its white translucent smart display provides user with information on the equipment and alarm systems status.
- KID-05.1 S controller included to control unit’s work parameters and change its configuration.
- Mono-Multi compatible.
- Optional WIFI control adding FRIWF-USB-02.
- K-Ion Technology: Active bipolar ionization included, we can actively help neutralize particles, bacteria, virus cells, odorous gases, aerosols and volatile organic compounds (VOCs).
OTHER CONTROLLERS
Individuals
KC-03.2 SPS| WiFi
K01-WIFI
---|---
|
Multifunction board
KMB-01| Optional WiFi
FRIWF-USB-02
|
PRODIGY
Technical Specifications
SET| AKAY-26 DR9| AKAY-35 DR9| AKAY-52 DR9| AKAY-71
DR9
---|---|---|---|---
Indoor unit| KAY-26 DR9| KAY-35 DR9| KAY-52 DR9| KAY-71 DR9
Outdoor unit| KAE-26 DR9| KAE-35 DR9| KAE-52 DR9| KAE-71 DR9
Capacity
| Cooling rated (min./max.)| kW| 2.64 (1.03 / 3.22)| 3.52 (1.38 /
4.31)| 5.28 (3.4 / 5.91)| 7.03 (2.11 / 8.21)
Heating rated (min./max.)| kW| 2.93 (0.82 / 3.37)| 3.81 (1.07 /
4.38)| 5.57 (3.11 / 5.87)| 7.33 (1.55 / 8.21)
Heating rated at -7°C| kW| TBD| TBD| TBD| TBD
Cooling input rated (min./max.)| W| 628 (90 / 1140)| 1034 (130 /
1650)| 1550 (560 / 2050)| 1500 (780 / 2000)
Heating input rated (min./max.)| W| 666 (110 / 1080)| 1027 (160 /
1560)| 2340 (420 / 3200)| 2130 (300 / 3100)
Heating input rated at -7°C| W| TBD| TBD| TBD| TBD
Energy efficiency| SEER – Energy class| 8.8 – A+++| 8.5 – A+++|
7.5 – A++| 6.5 – A++
SCOP – Energy class| 4.6 – A++| 4.6 – A++| 4 – A+| 4 – A+
Working range
| Outdoor ambient temperature for cooling min./max.| °C| -15ºC
/ 50ºC| -15ºC / 50ºC| -15ºC / 50ºC| -15ºC / 50ºC
Outdoor ambient temperature for heating min./max.| °C| -15ºC /
30ºC| -15ºC / 30ºC| -15ºC / 30ºC| -15ºC / 30ºC
Indoor ambient temperature for cooling min./max.| °C| 17ºC /
32ºC| 17ºC / 32ºC| 17ºC / 32ºC| 17ºC / 32ºC
Indoor ambient temperature for heating min./max.| °C| 0ºC /
30ºC| 0ºC / 30ºC| 0ºC / 30ºC| 0ºC / 30ºC
INDOOR UNIT| KAY-26 DR9| KAY-35 DR9| KAY-52 DR9|
KAY-71 DR9
---|---|---|---|---
Indoor unit| Air flow low/medium/high| m³/h| 305 / 365 / 480|
327 / 414 / 531| 540 / 710 / 800| 640 / 860 / 980
Sound pressure low/medium/high| dB(A)| 24 / 29 / 36.5| 25 / 33 /
39| 32 / 39 / 43.5| 33 / 42 / 46
Sound power level| dB(A)| 53| 53| 56.5| 62
Width/height/depth| mm| 805 / 302 / 193| 805 / 302 / 193| 964 / 325
/ 222| 1106 / 342 / 232
Net weight| kg| 8.7| 8.7| 11.3| 14.2
OUTDOOR UNIT| KAE-26 DR9| KAE-35 DR9| KAE-52 DR9|
KAE-71 DR9
---|---|---|---|---
Outdoor unit| Compressor type| Rotary| Rotary| Rotary| Rotary
Air flow| m³/h| 2150| 2200| 2100| 3500
Sound pressure| dB(A)| 54.5| 55| 56| 60.5
Sound power level| dB(A)| 59| 61| 64| 69
Width/height/depth| mm| 765 / 555 / 303| 765 / 555 / 303| 805 / 554
/ 330| 890 / 673 / 342
Net weight| kg| 26.7| 26.7| 33.5| 43.9
Power supply| V/ph/ Hz| 220-240/1/50| 220-240/1/50| 220-240/1/50|
220-240/1/50
Power wiring| mm²| (2+T)x1.5| (2+T)x1.5| (2+T)x1.5| (2+T)x2.5
Communication wiring| mm²| (4+T)x1.5| (4+T)x1.5| (4+T)x1.5|
(4+T)x2.5
Refrigerant| Type refrigerant| R-32| R-32| R-32| R-32
Refrigerant charge| kg| 0.62| 0.62| 1.1| 1.45
Liquid/gas pipe diameter| inch| 1/4″ / 3/8″| 1/4″ / 3/8″| 1/4″ /
1/2″| 3/8″ / 5/8″
Piping height difference| m| 10| 10| 20| 25
Piping max. length| m| 25| 25| 30| 50
Supplementary charge: Factory pre-charge for 5 m of installation.
Additional charge per metre added after 5 m.