Kaysun KHP-08-80 ACS1 Wall Hung Compak Owner’s Manual

June 1, 2024
Kaysun

Kaysun KHP-08-80 ACS1 Wall Hung Compak

Kaysun-KHP-08-80-ACS1-Wall-Hung-Compak-product

Specifications

  • Models: KHP-08/80 ACS1, KHP-09/100 ACS1, KHP-09/150 ACS1
  • Parts: Front plate, Front cover plate, Control box, Compressor, Water tank, 4-Way valve, Electronic expansion valve, Top plate, Upper cabinet, Evaporator, Mount bracket, Black Cover plate, Heater, Drain pan, Lower cabinet
  • Installation Requirement: Reliable earthing connection needed
  • Safety Precautions: Minimum water pressure of 0.15MPa, pressure reducer required for pressures above 5 bar (0.5 MPa)
  • Operation Principle: Heat pump transfers heat from lower to higher temperature source efficiently

Product Usage Instructions

Safety Information:

Please read thoroughly all of the instructions before installing or operating the unit. Always obey safety symbols provided in the manual.

Parts Names:

1: Front plate, 2: Front cover plate, 3: Control box, 4: Compressor, 5: Water tank, 6: 4-Way valve, 7: Electronic expansion valve, 8: Top plate, 9: Upper cabinet, 10: Evaporator, 11: Black Cover plate, 12: Drain pan, 13: Mount bracket, 14: Heater, 15: Lower cabinet

Basic Operation Principle:

The heat pump transfers heat from a lower temperature source to a higher temperature source with high efficiency.

Before Installation:

  1. Install the appliance in a frost-free room to avoid excess pressure caused by blockages in safety valves.
  2. Ensure the wall can support the weight of the appliance filled with water.
  3. Place the appliance in an accessible location for maintenance.

FAQS

  • Q: What should I do if I am unsure about the earthing of my house power supply?
    • A: If you are unsure about the earthing of your house power supply, do not install the unit yourself. Contact a qualified person such as a licensed plumber or authorized electric company personnel for assistance.
  • Q: Is it necessary to use a pressure reducer?
    • A: A pressure reducer is needed when the water pressure exceeds 5 bar (0.5 MPa) to ensure proper functioning of the unit.

“`

INSTALLATION & OWNER’S MANUAL
Wall Hung Compak

KHP-08/80 ACS1

KHP-09/100 ACS1

KHP-09/150 ACS1

Thank you very much for purchasing our product, Before using your unit , please read this manual carefully and keep it for future reference.

WARNING
This unit is required reliable earthing before usage, otherwise might cause injury.
If you can’t make sure that your house power supply is earthed well, please don’t install the unit. Please have a qualified person perform the reliable earthing connection and the installation of the unit. Examples of a qualified person include: licensed plumbers, authorized electric company personnel, and authorized service personnel. This installation manual needs to be used in conjunction with the safety manual.
Your safety is the most important thing we concerned!

PARTS NAMES

12

3

45

67

8 9 10 11 12 13 14 15

1:Front plate 2:Front cover plate 3:Control box

4:Compressor 5:Water tank 6:4-Way valve

7:Electronic expansion valve 8:Top plate 9:Upper cabinet

10:Evaporator

13:Mount bracket

11:Black Cover plate 14:Heater

12:Drain pan

15:Lower cabinet

NOTE
All the picture in this manual are for explanation purpose only. They may be slightly different from the heat pump water heater you purchased (depand on model). Please refer to the real sample instead of the picture of this manual.

CONTENTS

PAGE

SAFETY INFORMATION……………………………………………………………… 1 BASIC OPERATION PRINCIPLE…………………………………………………… 1 BEFORE INSTALLATION……………………………………………………………. 3 INSTALLATION………………………………………………………………………… 4 TRIAL- RUNNING…………………………………………………………………….. 10 OPERATION ………………………………………………………………………….. 13 TROUBLE SHOOTING………………………………………………………………. 19 MAINTENANCE………………………………………………………………………. 21 SPECIFICATIONS……………………………………………………………………. 23

0. SAFETY INFORMATION
Please read thoroughly all of the instrucitons before installing or operating the unit. Following safety symbol is very important, always read and obey all safety symbol:

cWhen the fan is rotating at high speed, it will cause injury.
cNever use a flammable spray such as hair spray, lacquer paint near the unit.It may cause a fire.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person.
cThe Minimum water pressure of the water transmission pipeline system is 0.15MPa.
cA pressure reducer (not supplied) is needed when pressure is more than 5 bar (0.5 MPa) and it will be placed on the main supply.

BASIC OPERATION PRINCIPLE

As we know with our experience, the natural flow of heat, which moves from a higher to a lower temperature source. the heat pump can transfer heat from a lower temperature source to a higher temperature source with high efficiency.

The advantage of a heat pump water heater is that it can supply more heat energy, normally 3 times than input electricity power by extracting the heat from ambient atmosphere in a free charge way to Sanitary Hot Water, compare to the traditional water heater, such as electric water heater or gas burner water heater, their efficiency is normally less than 1, which means it will dramatically cut off the bill of family daily SHW by the application of heat pump water heater, following data will show more details.

Power consumption comparison under the same condition to heat 1 ton water from 15°C to 55°C

The equivalent heat load Q=CM(T1-T2)=1(kCal/kg*°C ) X1000

(kg)(55-15)°C =40000kCal=46.67kWh

Table.0-1

HPW H

Gas Burner

E-heater

Energy

Resource

Air,Electricity

Gas

Electricity

Transfer Factor 860kCal/KWh 24000kCal/m³ 860kCal/kWh

Average Efficiency
(W /W )
Energy Consumption

3.9 11.93kW *h

0.8

0.95

2.08m³

49.13 kW*h

Unit Cost 0.09 USD/kWh 2.84 USD/m³ 0.09 USD/kWh

Running Cost

1.1

USD

5.9

4.42

Running Cost USD

E-heater

Gas Burner

HPWH

0

1

2

3

4

5

6

7

Fig.0-1

NOTE Above calculation is based on the ideal condition, the final cost bill will be different caused by the actual running conditions, such as running period, ambient temperature, etc.

1

cThe water inlet temperature of the equipment shall not be lower than 4°C, and the Maximum water temperature of the equipment can be set as 65°C(by changing the Settings, it can be raised to 70).
cInstall the appliance in a frost-free room. The warranty does not cover destruction of the appliance through excess pressure caused by a blockage in the safety valve.
cEnsure that the wall on which it is mounted can support the weight of the appliance filled with water.
cIf the appliance has to be installed in a room or location with an ambient temperature always above 35°C, this room must be ventilated.
cPlace the appliance in an accessible place. cTo allow the possible exchange of the heating
element, leave a clearance of 450 mm below the ends of the tubes of the water heater. cA new safety unit must be installed at the intake to the water heater, in a frost-free environment, with dimensions of G1/2″ and with pressure of 0.75 MPa, compliant with local regulations in force. cConnect the safety unit to a drain pipe kept in the open air, in a frost-free environment, with a permanent downward gradient, to remove any expansion water from the heating process, or drainage water from the water-heater cNo device (shut-off valve, pressure reducer, etc.) should be placed between the safety group and the cold water supply line of the water heater. cDo not connect hot water piping directly to the copper piping. It must be equipped with a dielectric connection ( not supplied with the appliance). cIn the event of corrosion of the threads of the hot water sprinkler not equipped with this protection, could not be applied. cSMART mode is not recommended when water consumption is low or irregular
This symbol indicates that this product shall not be disposed with other household wastes at the end of its service life. Used device must be returned to official collection point for recycling of electrical electronic devices. To find these collection systems please contact to your local authorities or retailer where the product was purchased. Each household performs important role in recovering and recycling of old appliance. Appropriate disposal of used appliance helps prevent potential negative consequences for the environment and human health.
2

! DANGER
HOT
BURN

BEFORE INSTALLATION

2.1 Unpacking
2.1.1 Accessories

Table.2-1

Accessory Name Qty. Sharp

Purpose

Owner’s & Installation Manual

1

Safety Valve (0.75MPa)

1

Installation and use instruction This manual
Prevent tank overpressure, prevent flowing backwards

Expansion screw

4

Fixed unit

2.1.2 How to transport

  1. In order to avoid scratch or deformation of the unit surface, apply guard boards to the contacting surface. No contact of fingers and other things with the vanes. Don’t incline the unit more than 75° in moving, and keep it vertical when installing.

75°
Gradient limit>75°

  1. This unit is heavy, it need to be carried by two or more persons, othewise might cause injury and damage.

2.2 Location requirements

  1. Enough space for installation and maintenance shall be preserved.
  2. The air inlet and outlet should be free from obstacles and strong wind.
  3. The wall surface should be flat, surface should be inclined no more than 2°and able to bear the weight of the unit and suitable for installing the unit without increasing noise or vibration.
  4. The operation noise and air flow expelled shall not affect neighbors.
  5. No flammable gas is leaked nearby. 6) It is convenient for piping and wiring. 7) If it is installed in indoor space, it might cause indoor temp
    decreased and noise. Please take preventive measures for this. 8) If the unit has to be installed on a metal part of building, make
    sure the well electric insulation which should meet the relevant local electric standard.

3

INSTALLATION

3.1 Maintenance space requirements (unit: mm)
Air outlet

350
Air intlet

350 Wall

Display
500

Fig.2-1

300

350

350

450

Fig.2-2

4

Make sure there is enough installation space.Outline dimensional drawing(see Fig.2-3,Fig.2-4)
3.2 Mounting dimension

If the wall is not load-bearing :

)
345
” installation holes

Model KHP-08/80 ACS1 KHP-09/100 ACS1 KHP-09/150 ACS1

A

B

H

317

270

1164

415

277

1328

558

475

1675

Fig.3-1
cPlace the water heater in a room protected from frost. cPlace it as close as possible to important points of use. cMake sure that the support element is sufficient to
receive the weight of the water heater full of water.
It is mandatory to install a retention basin below the water heater if installed above a living area. A drain connected to the sewer is required.
If the wall is load-bearing (concrete, stone, brick):

It is mandatory to install the water heater on a support . Place the water heater on the bracket to mark the fixing points. Make the holes and then reinstall the water heater in its place. The anti-tilting fixing by the upper bracket is obligatory (fixing Ø 10mm minimum adapted to the wall).

Wall

The hole size for hanging the 15-17mm wall should refer to the
corresponding hole size in Figure 3-1 (two racks for each water tank, a total of four expansion bolts need to be fixed).

After the expansion bolt is tightened, the distance between the inner side of the bolt and the wall surface should be controlled within 15mm-17mm, as shown in the figure.

  1. Installation of the Safety Valve: The spec of the One Way Valve thread in accessories is G1/2″. It is used to prevent water from flowing backwards and prevent tank overpressure

  2. After water system piping work, turn on the cold water inlet valve and hot water outlet valve and start effusing the tank. When water flow smoothly out from water outlet pipe(tap water outlet), the tank is full, turn off all valves and check pipeline to make sure there is no any leakage.

  3. If the inlet water pressure is less than 0.15MPa, a pump should be installed at the water inlet. For guarantee the safety usage of tank at the condition of water supply pressure higher than 0.5MPa, a reducing valve should be installed at the water inlet pipe.

  4. Condensate may be leaked from unit if drainage pipe is blocked or unit operates in high humidity environment, a drainage pan is recommanded as shown as following figure:

Max.22mm

Heat Pump Water Heater

Mark the wall with reference to the requirements of the installation size (size drawing). Proceed to the bolting of bolts Ø 10mm. The wall must hold a minimum load of 300 kg.

50mm larger than the dia. of unit

Fig.3-2

The water heater must be located in a space >15m³, and must have unrestricted air flow. As an example, a room that has an 2.5 tall ceiling and is 3 meter long by 2 meter wide would contain 15m³ .

5

Water inlet or outlet pipes: The spec of the water inlet or outlet thread is G1/2″ (external thread). Pipes must be heat-insulated well.
Unit outline dimension (unit: mm)

3.3 Air duct connection

  1. Air inlet and outlet with duct. (A+B5m)

B Air inlet

A Air outlet

160mm

H

Model
KHP-08/80 ACS1 KHP-09/100 ACS1 KHP-09/150 ACS1

Dimension 500cL×1196cH 500cL×1360cH 500cL×1708cH

Fig.3-1

L Fig.2-3 500

  1. Air inlet without duct, air outlet connects to duct. A5m

Air inlet

A Air outlet

160mm

Fig.2-4
NOTE Use tools to disassemble the filter for cleaning

*/

065

Fig.3-2
It is recommended to install unit by this way in the winter where there is other heat source in the room.

6

  1. Air inlet connects to duct, air outlet without duct.(A5m)

A Air inlet

Air outlet

Fig.3-3
It is recommended to install unit by this way in summer that could charge fresh air into room.

  1. Duct Description Duct

Round duct

Table.3-1
Rectangle duct

Dimension(mm)
Straight-line pressure drop (Pa/m) Straight-line length (m) Bent pressure drop(Pa)
Bent’s qty.

160 2 5 2 5

160X160 2 5 2 5

NOTE
The resistance of duct will decrease air-flow-rate, which will lead to capacity of unit decreased. For the case of unit with duct, the duct total length should be no more than 5m or the maximus static pressure should be within 20Pa, and the quantity of bending should be no more than 5.
For unit air outlet with duct, when unit operating, condensate will be generated aroud outside of duct. Please pay attention to the drainage work, we sugest to wrap the thermal insulated layer around ouside of the duct.
Must be install the unit in the indoor space, it is not allow to install the unit at the rainy space.

Weather shed

Rain

Unit Fig.3-4

7

  1. Filter installing at the unit inlet. In terms of the unit with duct, filter in there must be put on the position of duct inlet. (Fig.3-8/3-9)

inlet Filter

oulet

3.4 Electric Connection

Fig.3-5 D

2.5D

Filter

Owner should install the filter by self; and the mesh size is about 1.2mm.

Fig.3-6
6) To smoothly drain condensate from unit, please install the unit at a horizontal floor. Otherwise, please ensuring the drain vent is at the lowest place. Recommending the inclination angle of unit to the ground should be no more than 2°.

Water Outlet

Water Inlet
Drain

2o
Fig.3-7

3.4.1 Specifications of Power Supply
Model Name Power Supply MIin. Diameter of Power Supply Cord (mm2 ) Earth Cord(mm2 )

Table. 3-2 KHP-08/80 ACS1 KHP-09/100 ACS1 KHP-09/150 ACS1 220-240V50Hz
1.5
1.5

Please choose the power cord according to above table, and it should comply with local electric standard.
The power cord model, recommanded power cord mode is H05VV-F.
When wiring the power supply, please add additional insulation sheath at the place without rubber insulation layer.

8

3.5 Cold water connection
Before connection check that the piping is clean without any particles from installation. The installation has to include a new safety valve set to 7 bar ( 0,75 MPa ), compliant to EN 1487 and connected directly on the cold water inlet.
No hydraulic device (stop valve, pressure reduction, flexible…) is allowed between the safety valve and the cold water inlet of the water heater.
As water can flow from the safety valve the drain should be kept in open air. In any type of installation there should be a cold water stop valve, before the safety valve. The overflow of the safety valve has to be connected to the used water evacuation through a siphon. Installation has to be in a frost-free environment. The safety valve has to be operated regularly to check the working condition (1 – 2 times per month). The installation should be equipped with a pressure reduction if the main water supply pressure is higher than 5 bar (0,5 MPa). The pressure reducing device has to be installed at the beginning of the distribution network (before the safety valve). We recommend a supply pressure of 3 – 4 bar (0,3 to 0,4 MPa. The appliance cannot connected by a hose-set.

Safety valve

Cold water inlet
Siphon

Pressure reduction

3.6 Hot water connection
Do not connect copper tubes directly on the tank connection. You have to fit the supplied insulation union (not included in the supply). In case that the tank connection is corroded without this protection the warranty will not apply.
If the installation is made with synthetic pipes (e.g. : PER, multi-layer…), install mandatory a thermostatic control valve at the connection pipes of the water heater. The setting should be done in relation with the specification of the installed piping.
3.7 Condensate evacuation
The temperature drop of the air passing through the exchanger forms condensation from humidity in the air. The condensed water is evacuated on the rear of the tank using the supplied plastic tube.

Insulation union Water outlet Water intlet

Insulation union Drain pipe

shut off valve

Safety valve (include in the supply)

Depending on the degree of humidity in the air you can get up to 0,25l/h of condensation. The evacuation of condensate should not been made directly to sew water because of possible corrosive gasses damaging the exchanger fins and water heater parts.

EXPLOSION

3.7.1 Electric leakage protector

Power Supply

L
N
GND

Creepage Protector

Socket

Power Cable with Creepage Breaker

Fig.3-8

9

3.8 Installation checklist
3.8.1 Location
The wall must hold a minimum load of 300 kg.
Located indoors (such as a basement or garage) and in a vertical position. Sheltered from freezing temperatures.
Provisions made to shelter the area from water damage. Metal drain pan installed and piped to an adequate drain.
Sufficient room to service the water heater.
Sufficient air for the heat pump to function, the water heater must be located in a space >15m³, and must have unrestricted air flow. All piping properly installed and free of leaks. Unit completely filled with water. Water temperature limit valve or mixer tap(recommanded) installed per manufacturer’s instructions. The installation has to include a new safety valve set to 0,75 MPa, compliant to EN 1487 and connected directly on the cold water inlet. No hydraulic device (stop valve, pressure reduction, flexible…) is allowed between the safety valve and the cold water inlet of the water heater. As water can flow from the safety valve the drain should be kept in open air. In any type of installation there should be a cold water stop valve, before the safety valve.The overflow of the safety valve has to be connected to the used water evacuation through a siphon. Installation has to be in a frost-free environment. The safety valve has to be operated regularly to check the working condition (1 – 2 times per month).The installation should be equipped with a pressure reduction if the main water supply pressure is higher than 5 bar (0,5 MPa). The pressure reducing device has to be installed at the beginning of the distribution network (before the safety valve). We recommend a supply pressure of 0,3 to 0,4 MPa
3.8.2 Water System Piping
All piping properly installed and free of leaks.
Unit completely filled with water.
Water temperature limit valve or mixer tap(recommanded) installed per manufacturer’s instructions.
3.8.3 Condensate Drain Line Installation
Must be located with access to an adequate drain or condensate pump.
Condensate drain lines installed and piped to an adequate drain or condensate pump.

3.8.4 Electrical Connections The water heater requires 220-240 VAC for proper operation.
Wiring size and connections comply with all local applicable codes and the requirements of this manual.
Water heater and electrical supply are properly grounded.
Proper overload fuse or circuit breaker protection installed.
3.8.5 Post Installation Review
Understand how to use the User Interface Module to set the various modes and functions.
Understand the importance of routine inspection/maintenance of the condensate drain pan and lines. This is to help prevent any possible drain line blockage resulting in the condensate drain pan overflowing.
IMPORTANT: Water coming from the plastic shroud is an indicator that both condensation drain lines may be blocked. Immediate action is required.
To maintain optimal operation check, remove and clean the air filter.

TRIAL-RUNNING

4.1 Water affusion before operation
Before using this unit, please follow the steps below.
Water Affusion: If the unit is used for the first time or used again after emptying the tank, please make sure that the tank is full of water before turning on the power. Method: see Fig.4-1

Open the cool water inlet valve and the hot water outlet valve.

Open

Open

Cool water inlet

Hot water outlet

Water Affusion
When water flows out from the water outlet, the tank is full. Turn off the hot water outlet valve and water affusion is finished.
Close Hot water outlet

Water out

Fig.4-1

10

4.2 Trial- running
4.2.1 Checking list before commisionning.

  1. Checking list before trial-running. 2) Correct installation of the system.
  2. Correct connection of water/air piping and wiring;. 4) Condensate draining smoothly well insulation work for all
    hydraulic part. 5) Correct power supply. 6) No air in the water pipeline and all valves opened. 7) Effective electric leakage protector installation. 8) Sufficient inlet water pressure (between 0.15MPa and 0.5MPa).
    4.2.2 About Running
  3. System Structure Figure Unit has two kinds of heat sources: heat pump(compressor) and electric heater. Unit will automatically select heat sources to heat water to the target temperature.

Close the cool water inlet valve, open the hot
water outlet valve and open drainpipe. Open

Close

Hot water outlet

Cool water inlet

Open Drainpipe shut-off valve

Emptying
After emptying, please replace the nut of drainpipe.
Close Drainpipe shut-off valve

Fig.4-2

Temperature sensor(T5U) Temperature sensor(T5L)

Water outlet

Water inlet

Fig.4-3
2) Water Temperature Display The temperature shown on the display depends on the maximum of the upper sensor and the lower sensor.
3) Modes will be automatically selected by unit. manually mode selection is unavailable. Running Temperature Range Setting water temperature target range: 38~65ºC.
Table. 4-1

Min. temperature of room of installation
Max. temperature of room of installation
Heat pump
Minimum air inlet temperature(a)
E-heater
Heat pump
Maximum air inlet temperature(a)
E-heater

0ºC 43ºC -7ºC -20ºC 43ºC 45ºC

(a):Air inlet temperature range through air duct from outside (for models with air inlet duct).

11

Water temperature limits:

Table.4-2

Ambient air inlet Temp.(T4)

T4

-7T4-2 -2T42 2T435 35T443 43T4

Max.Temp.

(Heat pump) —

45

55

65

60

Max. Temp. (E-heater)

70°C(The maximum outlet temperature is set to 65°C by default.)

  1. Heat Source Shift
    The default heating source is heat pump. If ambient is range out of heat pump, heat pump will stop running, the unit will shift automatically to activate E-heater, then if the ambient temperature goes into the running range of heat pump again, it will stop E-heater and shift automatically to heat pump again.
    If the target setting water temperature is higher than Max. temp(Heat pump), the unit will activate heat pump firstly to the Max. temperature, then stop heat pump, activate E-heater to continually heat water to the target temperature.
    If manually activate the E-heater running when heat pump running, E-heater and heat pump will work together until the water temperature gets to target temperature. So if want to heat quickly, please manually activate E-heater.
    NOTE
    E-heater will be activated once for the current heating progress, if want to apply E-heater again, plsease push again.
    If system occurs some malfunctions, error code “EHHP” and will be shown on the display, then heat pump will stop running, and the unit will activate automatically E-heater as the backup heat source, but the code “EHHP” and will be shown until power off.
    Defrosting During Water-heating In heat pump running period, if the evaporator frosted in lower ambient temperature, the system will defrost automatically to keep effective performance(about 3~10min). At defrosting time(when the ambient temperature is below 5°C), the fan motor will stop, but compressor will still run.
    Heat-up Time There are different heat-up times in different ambient temperature. Normally lower ambient temperature result longer heat-up time because of lower effective performance. In the ECO mode, the heating time of the water temperature is 9-55°C,please refer to Table.4-3.Time difference may occur due to different installation scenarios. This is normal.

Timeh

Table.4-3

16.0

14.0

12.0

10.0

8.0

150L

100L

80L 6.0

4.0

2.0

0.0

-7

0

2

7

15

20

25

30

32

35

40

43

Ambient temp(

When ambient temp below 2°Cheat pump and E-heater will take different portions of heating capacity,

About TCO The power of compressor and E-heater will be automatically shut-off or turn on by TCO .
If the water temperature is higher than 85°C, the TCO will automatically shut off the power of compressor and E-heater. After that it needs to be reset manually.
Restart After a Long Term Stop When the unit is restarted after a long term stop(trail running included), it is normal that outlet water is unclean. Keep the tap on and the water will be clean soon.
NOTE
While the ambient air inlet temperature below than -7°C, heat pump efficiency will decrease dramatically, the unit will automatically shift to E-heater running.

4.2.3 Basic function

  1. Weekly disinfect function Under disinfection unit immediately start to heat water up to 65°C to kill the potential legionella bacteria inside water of tank, icon will light on the display screen during disinfection. Unit will quit disinfection if water temperature is higher than 65°C and extinguish icon.

  2. Vacation function

Press the

button to select VACATION , unit will automati

cally heat water to 15°C for the purpose of energy saving during

vacation days.

  1. How is the unit running

If unit is OFF->press

->unit will be waken->press

to set target water temperature(38-65°C)->press

->unit

will automatically select heat source and start to heat water to

target temperature.

  1. Remote shutdown function: Users can connect a switch. If the switch is closed, the unit will be stopped forcibly. If switch breaks, the unit can run normally according settings.

4.2.4 Query function

Press and hold the

button for 1 second then system running

parameters will be shown one by one with following sequence by

each pushing of

or button.

12

Table.4-3

Hour Min. No. low bit high bit

Min. Low bit

unit

Explenation

1T

5

2T

5

3T

5

4

T

5

T

6

T

7

T

8

T

9

O

10 T

F

11

T

12

C

13

F

14

15

16

17 P

U

18

P

19

F

20

H

21

H

22 F

S

23 S

1

24 P

4

25

U

26

U

27

U

28

U

U

Temp.

T5U

L

Temp.

T5L

1

Temp.

S

Temp. Heat pump stop temp

3

Temp.

T3

4

Temp.

T4

P

Temp.

TP

H

Temp.

Th

n

r

T

Temp. Disinfect temp.

O

Compressor and Current electric heating current

Ac Fan

O

Fan

0OFF 3HIGH 1LOW Dc Fan

2MID Real speed/10

O

Machine parameters

0~255

r

Eheater control type

C

Compression mechanism

hot water demand

P

5

T

0Ac Fan 1Dc Fan

T

1(Eheater control type)

P

0(Compressor control type)

1

O

Tank capacity

P

Four-way valve status

U

0

1

Version Host software version

2

Version LCD panel software version

3

Version 000

29

U

4

30

U

T

31 1

E

r

32 2

E

r

33 3

E

r

34 H

H

H

35 T

L

F

36

d

0One electric heater 1Two electric heaters 3 Last error code Previous 1 st error or protection code Previous 2 nd error or protection code
Maintenance time
Target Temp End sign

OPERATION

5.1 Control Panel Explanation

Display

Operation

Fig.5-1
5.2 Display Explanation
1 5 19 9 22 8 23 20 11 24 18 25 4 21 26 12 13 14 15 16 17

3

7 10 2 6

Fig.5-2

13

No Icon Description

Table.5-1

will be lightened if screen is unlocked.

It shows water temperature on normal;

It shows remaining vacation days on vacation;

It shows setting temperature on setting;

It shows unit setting/running parameters,

error/protection code on querying.

Time and clock setting

shows the clock. Whenever there is any setting for clock,

SET TIME will be lightened.

There are daily or weekly TIMER icon.

If anyone of them has been set, this icon

will lighten the corresponding one when screen is

3

unlocked

If there is none of timers has been set, it will keep

extinguished.

If timer is being set, this icon will flash the

corresponding one with 2Hz frequency as

well lighten the timer which has been set.

4

It flashes to remind the user to maintain the water tank.

5

It will be lightened when the machine is disinfecting.

Electronic magnesium rod reminder:

6

It will be lightened when the electronic magnesium

rod reaches the end of its service life.csome units

Lock:

7

If button is locked, the icon will be lightened,

otherwise it will be extinguished.

EVU:

8

When the photovoltaic effective signal is detected, this

icon lights up, this time the target temperature of the

machine is adjusted to the highest set temperature, and

the machine makes hot water quickly. csome units

E-heat: It will be lightened when E-heat is running, otherwise it will be extinguished.

NOTE: When the operating conditions are not met

9

to turn on this function, the corresponding icon on

the wire controller lights up briefly and then goes

out.

High temp. Alarm

10

If water temp is higher than 50°C, it will be lightened,

otherwise it will be extinguished.

11

Error: It will be lightened when unit is under protection/error.

VACATION MODE:

For the outgoing vacation mode, the water tank is set

12

at 15°C. Maintains low tank water temperature,

preheats hot water and anti-freeze lines, while

reducing on/off operation of the tank.

HYBRID MODE:

Operating in heat pump mode, the electric heater and

heat pump will heat up together when in extremely low

13

ambient temperatures or when the heat pump has been

running for a long time without reaching the set Temp.

E-HEATER MODE:

14

Operate in accordance with the heat pump mode, the

heat pump outdoor unit and the electric heater running

at the same time.

ECONOMY MODE: In accordance with the heat pump mode of operation,

the heat pump external unit heats up to the maximum

water temperature before turning on the electric

15

auxiliary heater for heating, the heat pump and the

electric auxiliary heater will not be turned on at the

same time.

It is recommended to use this mode of operation when

making hot water alone, which is more energy-saving.

HEAT PUMP MODE:

16

It will be lightened when the machine is running in

HEAT PUMP mode.csome units

SMART MODE:

Records the hot water usage habits of users over the

past 7 days and turns on the heating in advance

according to the user’s peak water usage hours. All

17

other unconventional hot water hours are in standby mode, without heating operation (it is recommended

that users set this mode after 7 days of regular and

normal operation of the water heater to avoid affecting

the normal use of the water heater by failing to record

the complete user habits.)csome units

18

When any key is invalid, this icon will flash 3 sec.

19

The icon lights up when the water temperature is being set.

20

The icon lights up when the clock is being set.

Wireless:

will be lightened when Wireless is connected;

will be extinguished when Wireless is not

21

connected;

will flash with 2Hz frequency when setting Wireless.

HEAT PUMP ICON:

22

When the heat pump is operating and producing hot

water, the icon lights up.

23

Smart Grid ICON: When the SG signal is invalid, this icon does not light

up and the machine does not switch on normally.

csome units

14

7

8 6

Fig.5-3 Any pressing of button is effective only under button and display unlocked state.
Table.5-2 No. Icon Description
Use this key to switch mode Default HYBRID mode
Switch to E-heater mode

No Icon
3

Description
INCREASE AND DECREASE If screen is unlocked, corresponding value will increase by pressing the button. When setting temperature, press more than 1s, temperature value will be increased continuously; When setting clock/timer, press more than 1s, clock/timer value will be increased continuously; When setting vacation days, press more than 1s, day value will be increased continuously; On querying, check items will page up by pressing it.

Checking function

  1. In the main interface, press and hold the search

key for 1 second to enter the spot check function,

and use the up and down keys to switch the spot

check channel, and the attribute value of the

channel will be displayed when switching to the

channel, and the specific channel can be found in

4

the function book.

  1. After 30 seconds from the last operation of the up

and down keys, or by pressing the return key or the

on/off key, you can directly exit the engineering

mode;

3Query mode can be entered in both power-on

and power-off state.

Switch to ECONOMY mode 1
Switch to VACATION mode
Adjust vacation days (1-360 days)
Switch to HYBRID mode

Click the button to turn on the forced sterilization function.

Icon

will light up. then the unit will

heat up water to 65°C at least for

disinfection.

When the machine is disinfectedpress this button to cancel it then the will be extinguished
2

This key is used to cancel all settings and exit the setting state. When Wireless connection is normal, long press the Cancel button for more than 8s to exit Wireless connection.
NOTE: When the operating conditions are not met to turn on this function, the corresponding icon on the wire controller lights up briefly and then goes out.

Engineering Mode

  1. In the main interface, press and hold the copy key

for 3 seconds to enter the engineering mode; use

the up and down keys to switch the inspection

channel, and the attribute value of the channel will

be displayed when switching to the channel. By up

and down key, you can modify a parameter setting,

after setting and adjusting, press confirm key to

return to the main interface to make the setting

effective (channel 2, 3, 4, 34, 35 will be effective

immediately). Press the Return button to return to

the previous interface (channel selection interface).

After 30 seconds from the last operation of the up

and down buttons, or by pressing the return button

or the on/off button, you can directly exit the

engineering mode.

5

2Engineering mode can be accessed in both

power-on and power-off state.

The factory default setting is air conditioning priority,

during engineering installation, it is necessary to

confirm its priority selection settings with the

customer and guide the instructions for use.

It is strictly prohibited for the customer to change the

parameter settings of other channels in the

engineering mode without authorisation to avoid

affecting the normal operation of the unit or causing

damage to the prototype.

  1. The current maximum set temperature is 65°C , if

you need to use a higher temperature, you can enter

the engineering mode 18 channel, raise the set

temperature upper limit, set the temperature upper

limit to 70°C

6

Power on/off button

Press the button to turn the device on or off.

15

No Icon 7

Description

TIMER (Daily setting)

  1. Press the TIMER button to the day timer icon

,

press the confirmation button to enter the day timer

setting interface, the day timer has a total of 6 time

periods, each time period can be set to open the time,

close the time, mode, set the temperature of the water;

when set the first time period set the temperature of the

water, press the confirmation button to enter the next

time period of the set; when set the sixth time period set

the temperature of the water, press the confirmation

button to return to the main interface; during this period,

you can press the return button

Return to the

previous setting or main interface;

  1. When setting the on time and off time, press the delete

button , the time can be restored to the default value,

and displaying ( -. –).

  1. If there is a conflict between the set time periods, the

time period set at the back will be the valid time period,

and the time period in front will be the invalid time period;

the invalid time period restores the default setting

  1. You can enter the daily timer setting in both power-on

and power-off state.

TIMER (Weekly setting)

  1. Press the TIMER button to the weekly timer icon

,

press the confirmation button to enter the weekly

timer setting interface, weekly timer a total of 7 days,

there are 6 time slots can be set each day, each time

slot can be set to open the time, close the time, the

mode, set the water temperature; when the first time

slot set the water temperature, press the confirmation

button to enter the next time slot settings; when the

sixth time slot set the temperature, press the confirma-

tion button to return to weekly After setting the water

temperature for the 6th period, press the confirmation

key to return to the selection of week; during this period,

you can press the return key to return to the previous

level of setting or the main interface;

  1. When setting the on time and off time, press the delete

button to restore the time, mode and set water

temperature to the default value, and displaying (-. –).

  1. If you adjust the timing time again after the setting is

completed, then all the settings after the adjustment

time period will be canceled. For example, if you adjust

the timer on for time period 2, the timer off for time

period 2, and the settings for time periods 3, 4, 5, and 6

will all be canceled to (-:—) after adjustment. Mode and

setting water temperature become default values

(Energy saving mode, 60°C)

  1. In the weekly timer setting, in the weekly selection,

use the copy button , you can locate the setting of a

certain day to the base day, select other days, press the

copy button to change the status of the day, the fast

flashing is selected, the slow flashing is unselected, and

after pressing on the confirmation button, you can copy

the setting of the base day to the selected day;

  1. You can enter the weekly timer setting in both power-on

and power-off state.

CONFIRM/UNLOCK

If screen and buttons are unlocked, press it to

7

upload setting parameters after setting any

parameter.

5.3 Combination button

Table.5-3

No.

Icon

Setting the date and clock

++

Description

  1. In the main interface, press and hold the timer button for 3 seconds to enter the date setting, press the up/down button to select the date, press the confirmation button to enter the clock setting, press the up/down button to modify the time, and press and hold to accelerate the increase/decrease of the time. After setting the clock, press the confirm button to return to the main interface to complete the setting of date and time. (2) After 30 seconds from the last operation of the up/down button or pressing the return button or the power on/off button, you can directly exit the date and time setting; 3) Setting can be done in both power-on and power-off state.

connecting the wireless function

Press for 3 sec

  1. In the main interface, long press the on/off key for 3 seconds to enter the AP wireless network mode, there will be a wireless icon in the upper right corner of the line controller. At this time, enter the APP, select the category of air water heater, choose the correct model, and then network according to the APP prompts, and after the network is completed, the wireless icon will be always on; (2) Wireless matching can last up to 8 minutes, after 8 minutes, if the matching is not successful, the wireless icon will go out;
  2. Long press the delete button for 8 seconds in the main interface to reset the wireless function; 4) It can be set in both power on and power off state. NOTE: Please check the 5.4 Using the SmartHome App for details.

Child lock function

Press for 2 sec

  1. In the main interface, long press the key combination for 2 seconds to enter the child lock state; (2) In the state of child lock, long press the key combination again for 2 seconds to release the child lock state; 3) In the locked state, there will be an icon next to the water temperature display.

16

5.4 Use Your Appliance with the NetHome Plus App
NOTE
Before you start, make sure that: 1.Your smartphone is connected to home
Wireless network, and you know the network password. 2.Make sure you are next to home appliances. 3.The 2.4GHz band wireless signal is enabled on your wireless router.
Download NetHome Plus App CAUTION: The following QR code is only available for downloading App. It is totally different with the QR code packed with uint. Android Phone users: scan Android QR code or go to google play, search “Nethome Plus” App and download it. IOS users: scan IOS QR code or go to APP Store, search “Nethome Plus” app and download it.

Add your appliance Tap the “+”icon to add home appliance to your NetHome Plus account.
Choose Air Source Heat Pump Water Heater.

Android

IOS

Register or Login account Open the App and create a user account, if you already have one, just log in.

Connected to the network.
Follow the instructions in the app to set up the Wireless connection. If the network connection fails,please refer to the App tips for operation.

17

5.5 Compliance
We, hereby declare that this device is in compliance with the relevant provisions of RE Directive 2014/53/EU. A copy of the full DoC is attached (Europen Union products only).
Wireless module models:
EU-SK110, US-SK110: FCC ID: 2ADQOMDNA23 IC: 12575A-MDNA23
BLE:2402-2480MHzTX Power:10dBm Wi-Fi:2400-2483.5MHzTX Power:20dBm
This device complies with Part 15 of the FCC Rules and it contains licence exempt transmitter(s) / receiver(s) that comply with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference; (2) This device must acceptany interference, including
interference that may cause undesired operation of the device.
Only operate the device in accordance with the instructions supplied. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) during normal operation.
In Canada:
CAN ICES-3(B)/NMB-3(B) Le présent appareil est conforme aux CNR Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fomctionnement du dispositif.

· Reorient or relocate the receiving antenna.
· Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
· Consult the dealer or an experienced radio/ TV technician for help.

5.6 Auto-restart If electricity power failed, unit can memorize all setting parameters, unit will be back to the previous setting when power recover.
5.7 Button Auto Lock When there is no operation of button for 1 minute, button will be

locked except Unlock button +

for 2s, unlock buttons.

5.8 Screen Auto Lock If there is no operation of button for 60s, screen will be locked(extinguished)
except for error code and alarm icon.Press any button will unlock the screen(lighten).Enter engineering mode 35 channel enable this
function.

Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu’aucune autre antenne ou émetteur. Cet équipement devrait être installé et actionné avec une distance minimum de 20 millimètres entre le radiateur et votre corps.

NOTE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
18

TROUBLE SHOOTING

6.1 Non-error tips
Q: Why compressor can’t start immediately after setting? A: Unit will wait for 3 min to balance the pressure of system before
start compressor again, it’s a self protection logic of unit.
Q: Why sometimes the temperature shown on the display panel decreased while unit is running?
A: When the upper tank temperature is much higher than the bottom part, upper part hot water will be mixed by the bottom cold water which is continually flow from inlet tap water so that will decrease the upper part temperature.
Q:Why sometimes the temperature shown on the display decreased but unit still keep closed?
A: to avoid unit ON/OFF frequently, unit will activate heat source only when bottom tank temperature is lower than setting temperature.
Q:Why sometimes the temperature shown on the display will decreased dramatically?
A: Because tank is pressure-bearable type, if there is massive hot demand, hot water will quickly tapped out from upper part of tank as well as cold water will quickly tapped into bottom part of tank, if the cold water surface emerge the upper temperature sensor, temperature shown on the display will decreased dramatically.
Q:Why sometimes the temperature shown on the display is decreased a lot, but there is still a mount of hot water can be tapped?
A:Because the upper water sensor is located on the upper 1/4 tank, when tapping hot water out, it means there is at least 1/4 tank of hot water available.
Q:Why sometimes unit shows “EHLA” on display ? A: When the unit does not have electric heating function, the heat pump available running ambient air inlet range is -7-43°C,if ambient air inlet temperature is out of range, system will show above-mentioned signal to let user notice it.
Q: Why sometimes the buttons are unavailable? A: if there is no operation on panel for 60s, unit will lock the panel,
shows ” “, to unlock the panel, please press the ” “+ ” “button for 2 seconds.
Q: Why sometimes there is some water flowed from drainage pipe of safety valve?
A: Because the tank is pressure-bearable one, when water is heated inside the tank, water will expand, so the pressure inside of tank will increase, if pressure goes up more than 1.0Mpa, safety valve
will activate to relief the pressure and hot water drop will be discharged correspondingly. If water drop is continually discharged from safety valve drainage pipe, it is abnormal, please contact qualified stuff to repair.

6.3 When Error happened

  1. If some normal errors happen, unit will automatically shift to E-heater for emergent SHW supply, please contact qualified staff to repair.
  2. If some sever error happen, unit will not start, please contact qualified staff to repair.

6.4 Error phenomenon shooting

Error phenomenon

Possible reason

Table.6-1 solution

Cold water tapped out and display screen extinguished

1. Bad connection between power supply plug and socket;
2. Setting water temperature too low;
3. Temp. sensor broken; PCB of indicator broken.

1. Plug in; 2. Setting water temp. higher; 3. Contact service center.

No hot water tapped out

1. Public water supply ceased;
2. Cold water inlet pressure too low (<0.15 MPa);
3. Cold water inlet valve closed.

1. Waiting for public water supply recover;
2. Waiting for inlet water pressure increase;
3. Open water inlet valve.

Water leakage

Hydraulic pipeline joints are not sealed well.

Check and reseal all joints.

6.2 Something about self-protection of unit

  1. When the self-protection happens, the system will be stopped and start self-check, and restart when the protection resolved.
  2. When the self-protection happens, the will flash and error code will be shown at water temperature indicator. But the and error code does not disappear until protection resolved.
    In the following circumstance, self-protection may happen: Air inlet or outlet is blocked; 3) The evaporator is covered with too much dust; Incorrect power supply(exceeding the range of 220-240V).

19

6.5 Error code shooting table

Display Malfunction Description EH0b Tank and LCD panel communication error.

Corrective action

Table.6-2

Maybe the connection between LCD panel and PCB has released or PCB has been broken.

EH00 EH03 PH15 EC54 EH5H

Machine working parameters are abnormal.

Contact a qualified person to service the unit.

Dc fan fault.

Maybe the connection between fan and PCB has released or fan has been broken. Contact a qualified erson to service the unit.

Electric leakage error. If PCB current_induction_circuit

check the current difference between L,N >14mA,

Maybe some wires have been broken or bad wire

system consider it as”electric leakage error”.

connection. Contact a qualified person to service the unit.

Compressor discharge temperature sensor TP error.

Maybe the connection between sensor and PCB has released or sensor has been broken. Contact a qualified person to service the unit.

Compressor suction temperature sensor TH error.

Maybe the connection between sensor and PCB has released or sensor has been broken. Contact a qualified person to service the unit.

EC53 Ambient temperature sensor T4 error.

Maybe the connection between sensor and PCB has released or sensor has been broken. Contact a qualified person to service the unit.

EC52 EH5L EH5U
EHLA EH5d EHHP

Evaporator temperature sensor T3 error. Error of sensor T5L(lower water temperature sensor)

Maybe the connection between sensor and PCB has released or sensor has been broken. Contact a qualified person to service the unit.
Maybe the connection between sensor and PCB has released or sensor has been broken. Contact a qualified person to service the unit.

Error of sensor T5U(upper water temperature sensor)

Maybe the connection between sensor and PCB has released or sensor has been broken. Contact a qualified person to service the unit.

When the ambient temperature T4 is out of the compressor operating range, the compressor stops, and EHLA is displayed until T4 returns to the normal It is normal, and no necessary to repair. range. Only works on units without electric heaters. Devices with electric heaters will never display “EHLA”.

electric heater open-circuit error

Maybe the electric heater has been broken or bad wire connection after repair.

Heat pump system fault. When PH20, PH21, PC30, PC06 any protection appears 3 times or the protection lasts 1 hour.

The compressor works abnormally. Contact a qualified person to service the unit.

PHdH Dry burning protection.

Ensure that there is water in the water tank before heating.

PH20 PH21 PH24 PC30 PC06 PH9b PH91

Compressor abnormally stopped protection The

Maybe because of compressor broken or bad connection

discharge temperature is not so higher than evaporator between PCB and compressor. Contact a qualified person

temperature after compressor running a term.

to service the unit.

The working current of the compressor is too large.

Maybe because of compressor broken, system blocked, air or water or more refrigerant in system(after repair), water temperature sensor malfunction, ect. Contact a qualified person to service the unit.

Frost protection.T5L< 4°C and T4 < 7°C

The cold water temperature is too low, which will affect the water tank. The electric heater will work.

System high pressure protection 3.0MPa active2.4Mpa inactive
High TP protection.Tp>110°CProtection active Tp<90°CProtection inactive
Overtemperature protection.The current water temperature exceeds the target temperature by more than 5 °C.
Low T3 protection.

Maybe because of system blocked, air or water or more refrigerant in system(after repair), water temperature sensor malfunction, ect. Contact a qualified person to service the unit.
Maybe because of system blocked, air or water or less refrigerant(leakage) in system( after repair), water temperature sensor malfunction, ect. Contact a qualified person to service the unit.
The water temperature sensor is faulty or the current water temperature is too high. In case of burns, contact a qualified person to check.
If the fault persists, Contact a qualified person to service the unit.

20

MAINTENANCE

  1. Checking of protective anodes.For more details, please contact the supplier or the after-sale service.

7.1 Maintenance

  1. Check the connection between power supply plug and socket and ground wiring regularly;
  2. In some cold area (below 0°C), if the system will be stopped for a long time, all the water should be released in case of freezing of inner tank and damage of E-heater.
  3. It is recommended to clean the inner tank and E-heater every half year to keep an efficient performance.For more details, please contact the supplier or the after-sale service.
  4. Check the anode rod every half year and change it, if it has been used out. For more details, please contact the supplier or the after-sale service.
  5. It is recommended to set a lower temperature to decrease the heat release, prevent scale and save energy if the outlet water volume is sufficient.
  6. Clean the air filter every month in case of any inefficiency on the heating performance. In terms of the filter set in air inlet directly (namely, air inlet without connect with duct), the method of dismantle the filter is: anti- clockwise unscrew the air inlet ring, take out the filter and clean it completely, finally, remount it to the unit.
  7. Before shutting the system off for a long time, please: Shut off the power supply; Release all the water in water tank and the pipeline and close all the valves; Check the inner components regularly.
  8. Reset the safety temperature limiter.For more details, please contact the supplier or the after-sale service. Before resetting the back-up temperature limiter , ensure that the operation has not been interrupted by activating a energy-saving contact ora time schedule. Check whether the safety temperature limiter of the additional electric heating has been set due to overheating (> 85 °C) or if it was triggered by a fault. Loosen the screws on the undercoat. Remove the undercoat . Press the key to reset the safety temperature limiter.

E-heater 4
nuts 3
undercoat 2
screws 1

5 Anode Rod

Empty the product. loosen the screws on the undercoat Remove the undercoat. Remove the cable from the electrical immersion resistance. Remove the nuts . Extract the groupwith the electrical resistance to immersion and the anode, the protective anode and the seal. Unscrew the protective anode and remove it from the hot water heater. Remove the protective anode and check the following point. Diameter (whole length): > 16 mm uniform wear of the protective anode. Check whether there are deposits of limestone on the immersion resistance. Check the anode of electrical resistance under immersion. If the protective anode is worn out, it shall be replaced by the same procedure as the immersion electric resistance anode. Replace the lining.

Fig.7-1

Reset

7.2 Recommended regular maintenance table
Table.7-1

Checking Item
1

Checking content
air filter (inlet)

Checking frequency every month

Action Clean the filter

2

anode rod

every half year

Replace it if it has been used out

3

inner tank

every half year

Clean the tank

4

E-heater

every half year

Clean E-heater

5

Safety valve every month

Check for blockage

For more details, please contact the supplier or the after-sale service.
21

8. SPECIFICATIONS
Model
Water-heating cap.(a)

KHP-08/80 ACS1 950W

KHP-09/100 ACS1 980W

Table. 8-1 KHP-09/150 ACS1 1300W

Rated power/AMPS

1950W/9A

1950W/9A

2250W/10.5A

Power supply

220-240V~ 50Hz

Operation control Protection
E-heater power Refrigerant

Auto/Manual startup, error alarm, timer,etc Over-load Protector, Temp Controller&Protector, Electric Leakage Protector, etc
1500W
R290/0.15kg

Water pipeline system

Outlet water temp.(b)

Default 50°C,(38-65°C adjustable

Water side exchanger

Aluminum microchannel heat exchanger

Inlet pipe Dia. Outlet pipe Dia.

DN15 DN15

Drain pipe Dia. Max. operating pressure

DN12 0.8MPa

Exchanger air side

Material

Aluminum fin, inner groove copper tube

Motor power Air circulation way

34W

34W

34W

Outlet/inlet vertically, duct connection available

Dimension Water tank cap.
Net weight

500×548×1195mm 500×548×1357mm 500×548×1707mm

78L

98L

145L

57kg

62kg

81kg

Fusible link type

T5A 250VAC/T16A 250VAC

The test conditions:
(a)aAmbient temperature 15/12°C(DB/WB), Water temperature from 15°C up to 45°C. (b)a70°C(The maximum outlet temperature is set to 65°C by default.)

22

RSJ- SMS 16122300001657
20230927

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Kaysun User Manuals

Related Manuals