Kaysun MKT3-V200F Fan coil Unit of Duct Type
Specifications
- Model Numbers: MKT3-V200F, MKT3-V300F, MKT3-V500F, MKT3-V600F, MKT3-V800F
- Product Type: Fan coil Unit of Duct Type
- Model Variants: (KFC-PD-4T-200D), (KFC-PD-4T-300D), (KFC-PD-4T-500D), (KFC-PD-4T-600D), (KFC-PD-4T-800D)
Product Usage Instructions
Precautions
Before installation and use, ensure compliance with local, national, and
international laws and regulations. Read all precautions carefully before
proceeding.
Safety Precautions
Important safety checks have been conducted before leaving the factory.
Follow the installation instructions strictly to prevent water leakage,
electrical shocks, and fire hazards.
Installation Guidelines
- The unit must be installed 2.3m above the floor.
- Avoid installing the appliance in a laundry area.
- Disconnect all supply circuits before accessing terminals.
- Ensure the appliance is easily accessible for maintenance.
- Use specified parts and accessories for installation to prevent equipment damage.
Electrical Work
- Follow local wiring standards and regulations for electrical work.
- Use an independent circuit and a single outlet for the appliance.
- Ensure tight connections and cable clamping to prevent heat or fire hazards.
Wiring Arrangement:
Properly arrange wiring routing to secure the control board cover.
Inadequate fixing may lead to heat-up, fire, or electrical shock risks.
Thank you very much for purchasing our air conditioner. Before using your air conditioner, please read this manual carefully and keep it for future reference.
PRECAUTIONS
- Be sure to conform with the local, national and international laws and regulations.
- Read “PRECAUTIONS” carefully before installation.
- The following precautions include important safety items. Observe them and never forget.
- Keep this manual in a handy place for future reference.
- Before out from the factory, the FAN COIL UNIT (AIR UNITS) has passed the Fan Coil Overpressure Resistant Test, Statically and Dynamically Balanced Adjustment, Noise Test, Air (cool) Volume Test, Electric Property Test, and Outline Quality Detection.
The safety precautions listed here are divided into two categories. In either case, important safety information is listed which must be read carefully.
WARNING: Failure to heed a warning can result in serious injury.
CAUTION: Failure to observe a caution may result in injury or damage to
the equipment.
After completing the installation, make sure that the unit operates properly during the start-up operation. Please instruct the customer on how to operate the unit and keep it maintained.
WARNING: Be sure only trained and qualified service personnel install,
repair or service the equipment.
Improper installation, repair, and maintenance may result in electric shocks,
short-circuits, leaks, fire or other damage to the equipment.
-
Install according to this installation instructions strictly. If the installation is defective, it will cause water leakage, electrical shock and fire.
-
When installing the unit in a small room, take measures to keep refrigerant concentration from exceeding allowable safety limits in the event of refrigerant leakage. Contact the place of purchase for more information. Excessive refrigerant in a closed ambient can lead to oxygen deficiency.
-
Use the attached accessories parts and specified parts for installation.
otherwise, it will cause the set to fall, water leakage, electrical shock and fire. -
The appliance must be installed 2.3m above the floor.
-
The appliance shall not be installed in the laundry.
-
Before obtaining access to terminals, all supply circuits must be disconnected.
-
The appliance must be positioned so that the plug is accessible.
-
The enclosure of the appliance shall be marked by word, or by symbols, with the direction of the fluid flow.
-
For electrical work, follow the local national wiring standards, regulations and installation instructions. An independent circuit and single outlet must be used.
-
If the electrical circuit capacity is not enough or defects in the electrical work, it will cause an electrical shock fire.
-
Use the specified cable connect tightly and clamp the cable so that no external force will act on the terminal.
-
If the connection or fixing is not perfect, it will cause heat-up or fire at the connection.
-
Wiring routing must be properly arranged so that the control board cover is fixed properly.
-
If the control board cover is not fixed perfectly, it will cause heat-up at the connection point of the terminal, fire or electrical shock.
-
If the supply cord is damaged, it must be replaced by the manufacturer its service agent or a similarly qualified person to avoid a hazard.
-
An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring.
-
When carrying out a piping connection, take care not to let air substances go into the refrigeration cycle.
-
Otherwise, it will cause lower capacity and abnormally high pressure in the refrigeration cycle.
-
Do not modify the length of the power supply cord or use of extension cord, and do not share the single outlet with other electrical appliances.
-
Otherwise, it will cause fire or electrical shock.
-
If the water leaks during installation, ventilate the area immediately.
-
After completing the installation work, check that the water does not leak.
-
The cool water in the unit is not lower than 3℃, hot water is not higher than 80℃. Water in the unit must be clean, and air quality must meet the standard of PH=6.5~7.5.
CAUTION
- Before installing the unit, it is necessary to check whether the ground wire is charged.
- If it is, the unit shall not be installed before correction.
- Ground the air conditioner.
- Do not connect the ground wire to gas or water pipes, a lightning rod or a telephone ground wire. Incomplete grounding may result in electric shocks.
- Be sure to install an earth leakage breaker.
- Failure to install an earth leakage breaker may result in electric shocks.
- Connect the outdoor unit wires, then connect the indoor unit wires.
- You are not allowed to connect the air conditioner with the power source until wiring and piping the air conditioner is done.
- While following the instructions in this installation manual, install drain piping to ensure proper drainage and insulate piping to prevent condensation.
- Improper drain piping may result in water leakage and property damage.
- Install the indoor and outdoor units, power supply wiring and connecting wires at least 1 meter away from televisions or radios to prevent image interference or noise.
- Depending on the radio waves, a distance of 1 meter may not be sufficient enough to eliminate the noise.
- This appliance can be children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.
DISPOSAL: Do not dispose of this product as unsorted municipal waste.
Collection of such waste separately for special treatment is necessary.
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities.
- Contact your local government for information regarding the collection systems available.
- If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
- Disconnect the power supply before cleaning and maintenance. Use a dry cloth to clean the unit.
Don’t install the air conditioner in the following locations:
- There is petrolatum existing.
- There is salty air surrounding (near the coast).
- There is caustic gas (the sulphide, for example) existing in the air (near a hot spring).
- The Volt vibrates violently (in the factories).
- In buses or cabinets.
- In the kitchen where it is full of oil gas.
- There is a strong electromagnetic wave existing. There are inflammable materials or gas.
- There is acid or alkaline liquid evaporating.
- Other special conditions.
INSTALLATION INFORMATION
- To install properly, please read this “Owner’s & Installation manual” first.
- The air conditioner must be installed by qualified persons. When installing the indoor unit or its tubing, please follow this manual as strictly as possible.
- If the air conditioner is installed on a metal part of the building, it must be electrically insulated according to the relevant standards to electrical appliances.
- When all the installation work is finished, please turn on the power only after a thorough check.
- Regret for no further announcement if there is any change of this manual caused by product improvement.
FUNCTIONS & FEATURES
- Nested in the ceiling, space-saving and noble.
- High capacity of cooling/heating performance, high efficiency and energy-saving.
- Adjust the indoor temperature rapidly and average.
- Low noise design.
- The air outlet is laid out in the way you desire.
ACCESSORIES
OPERATION RANGE
Use the system in the following temperature for safe and effective operation.
Temperature
Mode
| Outdoor temperature| Room temperature| Water inlet temperature
---|---|---|---
Cooling operation| 0°C~43°C| 17°C~32°C| 3°C~20°C
Heating operating (cooling only type without)| -15°C~24°C| 0°C~30°C| 30°C~80°C
NOTE
- If the air conditioner is used outside the above conditions, it may cause the unit to function abnormally.
- The phenomenon is normal in that the surface of air conditioning may condense water when the relative humidity in the room, please close the door and window.
- Optimum performance will be achieved within this operating temperature range.
- Water system operating pressure: Max: 1.6MPa, Min: 0.15MPa.
PARTS NAMES
The above figure is an instance model, which would be different from the one that you purchased.
INSTALLATION
Installing site
- Install the unit where enough space of installation and maintenance is available.
- Install the unit where the ceiling is horizontal and enough to bear the weight of the indoor unit.
- Install the unit where the air inlet and outlet are not baffled and are the least affected by external air.
- Install the unit where the supply airflow can be sent to all parts of the room.
- Install the unit where it is easy to lead out the connective pipe and the drain pipe.
- Install the unit where connotative heat is emitted from a heat source directly.
CAUTION
- Installing the equipment in any of the following places may lead to faults of the equipment (if that is inevitable, consult the supplier):
- The site contains mineral oils such as cutting lubricant.
- Seaside where the air contains much salt.
- Hot spring areas where corrosive gases exist, e.g., sulphide gas.
- Factories where the supply voltage fluctuates seriously. Inside a car or cabin.
- A place like the kitchen where oil permeates.
- A place where strong electromagnetic waves exist.
- A place where flammable gases or materials exist.
- A place where acid or alkali gases evaporate.
- Other special environments.
Precautions before installation
- Decide the correct way of conveying the equipment.
- Try to transport this equipment with the original package.
- If the air conditioner needs to be installed on a metal part of the building, electric insulation must be performed, and the installation must meet the relevant technical standards of electric devices.
- Before installing the unit, be sure to confirm with the user whether there are wires, water pipes, air pipes and so on in the wall or ground of the installation site to avoid accidents due to damage.
Installing the fan coil units
Confirm the dimensions of the indoor unit against the following figure.
- Install Φ10 pendant bolts (4 bolts)
- The intervals of the pendant bolts are shown in the following figure.
- Use the Φ10 pendant bolts.
- The treatment of the ceiling varies between buildings. For detailed measures, negotiate with the construction and fit-out staff.
- Scope of dismantling the ceiling…Please keep the ceiling horizontal. Reinforce the beams and girders of the ceiling lest vibration of the ceiling.
- Cut off the beams and girders of the ceiling.
- Reinforce the cut-off part, beams and girders of the ceiling.
- After the main body is suspended, work on the pipes and wires in the ceiling. Decide the lead-out direction of the pipes after selecting the installation site. Especially, in a circumstance where a ceiling is available, extend the refrigerant pipe, drain pipe, indoor/outdoor connection wires and wire controller lines to the connection position before suspending the unit.
The procedure of installing the pendant bolts.
-
Based on the unit structure, please set the screw pitch according to the size of the following figures: Wooden structure
-
Put rectangular sticks across the beams, and set pendant bolts.
-
Old concrete roughcast
Use embedded bolts and embedded pulling plugs. -
Steel beam and girder structure
Set and use supportive angle steel. -
New concrete roughcast
Set it with embedded bushes or embedded bolts.
Suspending the indoor unit
Use tools such as pulleys to hoist the indoor unit to the pendant bolt.
Use tools such as gradienter to settle the indoor unit horizontally. Lack of
horizontality may cause water leak.
Connect the duct
The duct length is determined according to the external static pressure.
Install the wire control switch
For installation of the wire control switch, see the installation manual of
the wire controller.
Space requirement.
Sample unit specification figure
Four pipe type (unit:mm)
The quantities of the fans and motors are only for reference, please prevail
in kind!
Model
Size
| ****
200-Model
| ****
300-Model
| 400-Model 500-Model| ****
600-Model
| ****
800-Model
---|---|---|---|---|---
A| 545| 645| 745| 965| 1265
B| 485| 585| 685| 905| 1205
C| 513| 613| 713| 933| 1233
D| 485| 585| 685| 905| 1205
E| 741| 841| 941| 1161| 1461
F| 583| 683| 783| 1003| 1303
NOTE
- The above figure is an instance model, which would be different from the one that you purchased.
- The broken lines in the above figures illustrate the dimensions of air return box. (Lower side air return box and rear air return box)
- If you need to order air return box from us, please be specific and describe which kind you need.
Connect the accessional plastic water tray (no air return box type)
- The grooves of the accessional plastic water tray can be locked at the brim of the main water tray.
- Please hang up the accessional plastic water tray to the pipes or ceiling by a rope.
PIPES CONNECTION
- With an air release valve, the other side is a water inlet pipe.
- When connecting the water collecter, set the tightening torque to 6180~7540N.cm(630~770kgf.cm), and use a spanner to tighten it as shown in Figure.
- The diameter of the connective junction in the water inlet pipe and water outlet pipe is RC3/4 tapper pipe thread inside.
- The diameter of the condensate pipe is ZG3/4 tapper pipe thread outside.
INSTALLATING DRAINAGE PIPE
Install the drain pipe of the fan coil unit
Before out from factory, the scupper adopts the pipe thread.
NOTE
- Be sure to perform heat insulation for the drain pipe of the indoor unit. Otherwise, condensate will occur. The joint of the indoor unit should also undergo heat insulation treatment.
- When performing the pipes connection, use the rigid PVC binder, and make sure that no leak exists.
- Same as the joint of the indoor unit. Be careful not to apply force at the pipe side of the indoor unit.
- The downward gradient of the drain pipe should be higher than (1/100), without bend in the middle.
- The total length of the drain pipe when pulled out traversely shall not exceed 20m, when the pipe is over long, a prop stand must be installed prevent winging.
- The centralized pipes should be distributed against the figure shown on the right side.
Drain test
- Before the test, ensure that the drain pipes are smooth and the adapters are sealed.
- Newly built rooms should undergo the drain test before the ceiling is laid.
WIRING
CAUTION
- The air conditioner should use a separate power supply with a rated voltage.
- The external power supply to the air conditioner should have ground wiring, which is linked to the ground wiring of the indoor and outdoor unit.
- The wiring work should be done by qualified persons according to the circuit drawing.
- An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring. The appliance shall be installed by national wiring regulations.
- Be sure to locate the power wiring and the signal wring well to avoid cross-disturbance.
- Do not turn on the power until you have checked carefully after wiring.
- The temperature of the refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
AIR FLOW(CFM)
| 200~800
---|---
POWER
| PHASE| 1-phase
FREQUENCY AND VOLT| 220-240V~ 50Hz
CIRCUIT BREAKER/FUSE(A)| 15/15
INDOOR UNIT POWER WIRING(mm2)
| BELOW 20M| Twisted pairwire:2.5
BELOW 50M| Twisted pairwire:6
GROUND WIRING(mm2)| 2.5
The power cord type designation is H05RN-R or above/H07RN-F.
Wiring Diagram
- The default model of the DC fan coil is set as 12Pa when leaving the factory.
- Clients can dial to the responding position to choose the model and static pressure according to the nameplate and actual static pressure requirements of the models and static dial code table .
Models and static dial code table
Fault and Protection
When the unit is subject to failure, main board corresponding LED4 will
flash. Fault code table and Protection:
NO. | Fault Name | Main board LED4 light |
---|---|---|
1 | Fan failure | LED4 light flash 4 (flashing frequency 2Hz) stop 2s, cycle of |
action
2| Not set models| LED4 light continue to flashing(flashing frequency 2Hz)
The A-weighted sound pressure level is below 70dB.
Tables
MODE:MKT3-V200F
Information to identify the model(s)to which the information relation:
Item| Symbol| Value| Unit
Cooling capacity(sensible)| Prated,c| 1.374| kW
Cooling capacity(latent)| Prated,c| 0.29| kW
Heating capacity| Prated,h| 2.453| kW
Total electric power input| Pelec| 0.017| kW
Sound power level(per speed setting,if applicable)| LWA| 51.1/41.1/38.7| dB
contact details|
MODE:MKT3-V300F
Information to identify the model(s)to which the information relation:
Item| Symbol| Value| Unit
Cooling capacity(sensible)| Prated,c| 2.106| kW
Cooling capacity(latent)| Prated,c| 0.447| kW
Heating capacity| Prated,h| 3.467| kW
Total electric power input| Pelec| 0.022| kW
Sound power level(per speed setting,if applicable)| LWA| 51.7/45.0/38.7| dB
contact details|
MODE:MKT3-V400F
Information to identify the model(s)to which the information relation:
Item| Symbol| Value| Unit
Cooling capacity(sensible)| Prated,c| 2.445| kW
Cooling capacity(latent)| Prated,c| 0.534| kW
Heating capacity| Prated,h| 4.309| kW
Total electric power input| Pelec| 0.03| kW
Sound power level(per speed setting,if applicable)| LWA| 54.3/48.3/40.0| dB
contact details|
MODE:MKT3-V500F
Information to identify the model(s)to which the information relation:
Item| Symbol| Value| Unit
Cooling capacity(sensible)| Prated,c| 2.821| kW
Cooling capacity(latent)| Prated,c| 0.449| kW
Heating capacity| Prated,h| 4.705| kW
Total electric power input| Pelec| 0.043| kW
Sound power level(per speed setting,if applicable)| LWA| 57.6/50.5/42.5| dB
contact details|
MODE:MKT3-V600F
Information to identify the model(s)to which the information relation:
Item| Symbol| Value| Unit
Cooling capacity(sensible)| Prated,c| 3.601| kW
Cooling capacity(latent)| Prated,c| 0.805| kW
Heating capacity| Prated,h| 6.034| kW
Total electric power input| Pelec| 0.05| kW
Sound power level(per speed setting,if applicable)| LWA| 59.1/52.2/43.7| dB
contact details|
MODE:MKT3-V800F
Information to identify the model(s)to which the information relation:
Item| Symbol| Value| Unit
Cooling capacity(sensible)| Prated,c| 4.73| kW
Cooling capacity(latent)| Prated,c| 0.988| kW
Heating capacity| Prated,h| 7.226| kW
Total electric power input| Pelec| 0.065| kW
Sound power level(per speed setting,if applicable)| LWA| 60.2/52.2/44.4| dB
contact details|
FAQ
- Q: Can I install the appliance in a small room?
- A: When installing in a small room, take precautions to prevent refrigerant concentration from exceeding safety limits in case of leakage. Contact the seller for more information.
- Q: What should I do if the appliance malfunctions after installation?
- A: Ensure only trained service personnel handle repairs or maintenance to prevent electrical hazards or equipment damage.
OFICINA CENTRAL
- Blasco de Garay, 4-6 08960 Sant Just Desvern Barcelona
- Tel. 93 480 33 22 http://www.frigicoll.es
BUREAU CENTRAL
- Pare Silic-lmmeuble Panama 45 rue de Villeneu 94150 Rungis
- Tel. +33 9 80 80 15 14 http://www.frigicoll.es
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>