Klein Tools NCVT-2PKIT Electrical Test Kit Instruction Manual

September 28, 2024
KLEIN TOOLS

Klein Tools NCVT-2PKIT Electrical Test Kit

PRODUCT KEYS

  1. NCV Power On/Off Button
  2. Power On/Mode LEDs
  3. Voltage Detection LEDs (Inside Tip)
  4. Non-Contact Tip
  5. Pocket Clip
  6. O-ring Seal
  7. Battery Cap
  8. 2x AAA Batteries (Included)

NOTE: There are no user-serviceable parts inside the tester.

  • Detects AC voltage from 12 to 1000V with visual & audible indicators
  • Two detection ranges: 70 to 1000V and 12 to 1000V
  • Auto power-off feature conserves and extends battery life

DURABILITY

  • Drop Protection 6.6 ft. (2 m)
  • Safety Rating CAT IV 1000V

SYMBOLS ON TESTER

  • Warning – Risk of electric shock
  • Risk of danger. Important information: It is important that users of this tester read, understand, and follow all warnings, cautions, safety information, and instructions in this manual before operating or servicing this tester. Failure to follow instructions could result in death or serious injury.
  • Double insulated
  • Read instructions
  • Conformité Européenne
  • This product has been independently tested by Intertek and meets applicable published standards
  • For measurements performed at the source of low-voltage installation and outside lines.

RT105

Receptacle Tester

Designed to detect the most common wiring problems in standard receptacles: Open ground, reverse polarity, open hot, open neutral, hot/ground reversed

DURABILITY

  • Drop Protection 3.3ft. (1 m)
  • Safety Rating CAT II 125V

KEY :

  • Indicator Illuminated
  • Indicator Not Illuminated

DIAGNOSTICS CHART

GENERAL SPECIFICATIONS

The Klein Tools NCVT-2P is a dual-range non-contact voltage tester (NCVT). It can be set to detect voltage from 70 to 1000V AC (Mode 1), or from 12 to 1000V AC (Mode 2) for low voltage and higher sensitivity.

  • Environment: Indoor or outdoor
  • Measurement Range:
    • Mode 1: 70 to 1000V AC
    • Mode 2: 12 to 1000V AC
  • Frequency Range: 50 to 500 Hz
  • Batteries: 2x AAA 1.5V Alkaline
  • Operating and Storage Altitude: Up to 6562 ft. (2000 m)
  • Operating and Storage Temp: 14° to 122°F (-10° to 50°C)
  • Relative Humidity: <95% non-condensing
  • Dimensions: 5.82″ x 0.87″ x 1.08″ (147 x 22 x 27.4 mm)
  • Weight: 2.5 oz. (72 g) including batteries
  • Pollution degree: 2
  • Safety Rating: CAT IV 1000V AC
  • Drop Protection: 6.6 ft. (2 m)
  • Standards:
    • EN61010-1:2010, EN61010-2-030:2010,
    • EN61326-1:2013, EN61326-2-2:2013. Conforms to UL STD. 61010-1, 61010-2-030
    • Certified to CSA STD. C22.2 No. 61010-1, 61010-2-030.

Specifications subject to change.

FUNCTION BUTTONS

NCV POWER ON/OFF BUTTON 1

  • To activate the Non-Contact Voltage Testing feature, press and release the NCV Power-ON button.
  • After performing a self-test the tester will emit a single beep, one of the Power ON LED’s 2 will illuminate indicating which NCVT mode is active (see OPERATING INSTRUCTIONS), and a green light will illuminate in the tip 3 . To power-OFF the tester, press and hold the NCV button.

NOTE: The tester will automatically power-OFF following 4 minutes of inactivity to conserve battery life.

WARNINGS

To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in severe injury or death.

  • Risk of electric shock and burn. Contact with live circuits could result in death or serious injury.
  • Use caution with voltages above 25V AC as a shock hazard may exist.
  • A blinking LED or a steadily illuminated LED in the tip and audible beeps indicate presence of voltage. If no indication, voltage could still be present.
  • Before and after each use, verify operation by testing a known working circuit that is within the rating of this unit.
  • Never assume neutral or ground wires are de-energized. Neutrals in multi-wire branch circuits may be energized when disconnected and must be retested before handling.
  • The tester WILL NOT detect voltage if:
  • The wire is shielded.
  • The operator is not grounded or is otherwise isolated from an effective earth ground.
  • The voltage is DC.
  • The tester MAY NOT detect voltage if:
  • The user is not holding the tester.
  • The user is insulated from the tester with a glove or other materials.
  • The wire is partially buried or in a grounded metal conduit.
  • The tester is at a distance from the voltage source.
  • The field created by the voltage source is being blocked, dampened, or otherwise interfered with.
  • The frequency of the voltage is not a perfect sine wave between 50 and 500Hz.
  • The tester is outside of operating conditions (listed in Specifications section).
  • Operation may be affected by differences in socket design and insulation thickness and type.
  • In bright light conditions, the LED visual indicators will be less visible.
  • When powered-ON, one of the “power-ON” LED’s will be illuminated, and a green light will illuminate the tip. DO NOT USE TESTER UNLESS ONE OF THE “POWER-ON” LEDs IS ILLUMINATED .
  • Do not use if tester appears damaged or is not operating properly. If in doubt, replace the tester.
  • Do not apply more than the rated voltage as marked on the tester (1000V).
  • Do not apply to uninsulated hazardous live conductors.
  • Detection above 70V AC in Mode 1, or above 12V AC in Mode 2 is specified under “normal” conditions as detailed below. The tester may detect at a different threshold at different conditions, or may not detect at all unless:
  • The tip of the tester is within 0.25″ (6 mm) of an AC voltage source radiating unimpeded.
  • The user is holding the body of the tester with his or her bare hand.
  • The user is standing on or connected to earth ground.
  • The air humidity is nominal (50% relative humidity – non-condensing).
  • The tester is held still.
  • Always wear approved eye protection.
  • Comply with local and national safety requirements.
  • If this product is used in a manner not specified by the manufacturer, protection provided by the product may be affected.

CAUTION

  • DO NOT attempt to repair this tester. It contains no serviceable parts.
  • DO NOT expose tester to extremes in temperature or high humidity.

OPERATING INSTRUCTIONS

SELECTING VOLTAGE TESTING MODE NCVT-2P can detect voltage in two distinct modes, defined by the voltage ranges to which the tester is sensitive. Mode 1 detects 70 to 1000V AC, Mode 2 detects 12 to 1000V AC. With the tester powered-ON, successive presses of the NCV Power-ON button 1 will switch the tester between modes 1 and 2. The Power-ON indicator LED’s 2 will indicate the currently active mode. The tester will power-ON in the mode that was most recently used.

OPERATING INSTRUCTIONS

CHECKING FOR THE PRESENCE OF AC VOLTAGE

  1. Press NCV Power On/Off button. After performing a self-test, a green light will illuminate the tip when no voltage is detected.
  2. Prior to use, test on a known live circuit to verify tester functionality.
  3. Place tip of the tester 4 near AC voltage. If voltage is present, the unit will emit audible beeps and the LEDs in the tip 3 will illuminate:
Mode Power-On LED Color 12 to 70V AC > 70 to 1000V AC

Mode 1

70 – 1000V

Range

| Red| No illumination, no sound| Red LED in tip 3

illuminated, continuous audible beep

Mode 2

12 – 1000V

Range

| Blue| Blue LED in tip 3

blinking, pulsing audible beep

| Red LED in tip 3

illuminated, continuous audible beep

NOTE: In Mode 2, the tester is more sensitive to high voltage sources and electrically noisy environments. It is recommended to set the tester to operate in Mode 1 when expected voltages are above 70V AC.

SILENT OPERATION

To activate silent operation, power-ON by pressing and holding the NCV Power- ON button 1 for more than 2 seconds. Power-ON in this manner each time silent operation is desired.

MAINTENANCE

BATTERY REPLACEMENT

When the battery is low, the unit powers on with a blinking red or blue LED 2 , depending on mode most recently used, and the batteries must be replaced.

  1. Unscrew the battery cap 7 and remove/recycle spent batteries.
  2. Install two new AAA batteries. Note proper polarity.
  3. Screw battery cap tightly to ensure a tight seal with the O-Ring 6 .

RT105

GENERAL SPECIFICATIONS

The Klein Tools RT105 is a receptacle tester designed to detect the most common wiring problems in standard receptacles.

  • Operating Temperature: 32° to 104°F (0°C to 40°C) < 80% R.H.
  • Storage Temperature: 14° to 122°F (-10°C to 50°C) < 70% R.H. Weight: 1.5 oz. (43 g)
  • Nominal Voltage: 110-125V AC at 50/60Hz in 3-wire outlet Nominal Power: 0.3W
  • Certification: Conforms to: UL61010-1,
  • Certified to: CSA-C22.2 #61010-1 Safety: CAT II 125V, Class 2, Double Insulation Drop Protection: 3.3 ft. (1 m)

WARNINGS

Read, understand, and follow all warnings and instructions before operating testers. Failure to follow instructions could result in death or serious injury. Before each use, verify tester operation by testing on a known live and correctly wired receptacle. Do not use if the tester appears damaged in any way. The tester is intended for indoor use only. Other equipment or devices attached to the circuit being tested could interfere with the tester. Clear the circuit before testing. Always consult a qualified electrician to resolve wiring problems.

WIRING CONFIGURATION TESTING

  • Conditions indicated: The wiring conditions that may be identified are correct wiring, open ground, hot-ground reversed polarity, open hot, open neutral, hot-neutral reversed polarity.
  • Conditions NOT indicated: Quality of ground, multiple hot wires, combinations of defects, and reversal of grounded and grounding conductors.
  1. Verify tester operation by testing on a known live and correctly wired receptacle.
  2. Insert the tester into the receptacle under test to check for correct wiring (Fig. 1). Lights on the tester should illuminate.
  3. Compare lit bulbs on tester to the key code printed on the tester.
  4. If tester does not show the receptacle to be wired correctly, consult a qualified electrician.

CLEANING

  • Be sure tester is turned off and wipe with a clean, dry lint-free cloth. Do not use abrasive cleaners or solvents.

STORAGE

  • Remove the batteries when not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications section, allow the tester to return to normal operating conditions before using.

DISPOSAL / RECYCLE

****Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations. Please seewww.epa.gov or www.erecycle.org for additional information.

CUSTOMER SERVICE

KLEIN TOOLS, INC. 450 Bond Street, Lincolnshire, IL 60069 1-800-553-4676

FREQUENTLY ASKED QUESTIONS

What is the brand and model of this electrical test kit?

The brand is Klein Tools, and the model is NCVT-2PKIT.

What is the price of the Klein Tools NCVT-2PKIT Electrical Test Kit?

The Klein Tools NCVT-2PKIT is priced at $29.48.

What is the power source for the Klein Tools NCVT-2PKIT?

The Klein Tools NCVT-2PKIT operates on a corded electric power source.

What is the item weight of the Klein Tools NCVT-2PKIT?

The item weight of the Klein Tools NCVT-2PKIT is 1.6 ounces.

What is the voltage detection range for the Klein Tools NCVT-2PKIT?

The voltage detection range is 12 to 1000V AC.

What is the low voltage detection range for the Klein Tools NCVT-2PKIT?

The low voltage detection range is 12 to 48V AC.

What is the standard voltage detection range for the Klein Tools NCVT-2PKIT?

The standard voltage detection range is 70 to 1000V AC.

What visual indicators are included in the Klein Tools NCVT-2PKIT?

The Klein Tools NCVT-2PKIT features a green LED (operational) and a red LED (voltage detected).

What type of batteries does the Klein Tools NCVT-2PKIT require?

The Klein Tools NCVT-2PKIT requires 2 x AAA batteries.

What is the battery life of the Klein Tools NCVT-2PKIT?

The battery life can last up to 142 hours.

What is the drop protection for the Klein Tools NCVT-2PKIT?

The Klein Tools NCVT-2PKIT offers drop protection from heights of up to 6.6 feet (2 meters).

What is the ingress protection rating for the Klein Tools NCVT-2PKIT?

The ingress protection rating is IP54, indicating it is dustproof and waterproof.

What are the product dimensions of the Klein Tools NCVT-2PKIT?

The product dimensions are 1 x 1 x 1 inches.

What is the overall length of the Klein Tools NCVT-2PKIT?

The overall length is 5.82 inches (14.8 cm).

What is the overall height of the Klein Tools NCVT-2PKIT?

The overall height is 0.86 inches (2.2 cm).

VIDEO – PRODUCT OVERVIEW

DOWNLOAD THE PDF LINK:Klein Tools NCVT-2PKIT Electrical Test Kit Instruction Manual