TCL THMLd4D-3HBp-A Mono Split Heating and Cooling System Owner’s Manual
- September 27, 2024
- TCL
Table of Contents
TCL THMLd4D-3HBp-A Mono Split Heating and Cooling System
Product Usage Instructions
- Ensure the power supply matches the specifications provided.
- Follow the installation manual to set up the unit securely.
- Make appropriate piping connections for cooling and heating.
- Power on the unit using the designated power switch.
- Set the desired temperature using the control panel.
- Select the mode of operation (heating, cooling, hot water) based on your requirement.
- Regularly clean the air filters to ensure efficient operation.
- Schedule professional maintenance checks at least once a year.
FAQ
- Q: What is the recommended power supply for this product?
- A: The recommended power supply is 220-240V/1/50Hz.
- Q: How often should I clean the air filters?
- A: It is recommended to clean the air filters every 2-3 weeks for optimal performance.
- Q: Can this product be used for both heating and cooling?
- A: Yes, this product is designed for both heating and cooling applications.
Mono product parameters
Model name
| THMLd- 4D/3HBp
– A
| THMLd- 6D/3HBp
-A
| THMLd- 8D/3HBp
– A
| THMLd- 10D/3HBp
– A
| THMLd- 12D/3HBp
– A
| THMLd- 14D/3HBp
– A
| THMLd- 16D/3HBp
– A
| THMLd- 12S/6(9) HBp-A| THMLd- 14S/6(9) HBp-A| THMLd- 16S/6(9) HBp-A
---|---|---|---|---|---|---|---|---|---|---
Power supply| V/Ph/Hz| 220-240/1/50| 220-240/1/50| 380-415/3/50
Heating A7W35
| Capacity| kW| 4.20| 6.22| 8.00| 9.50| 12.10| 14.50| 16.00| 12.10| 14.50|
16.00
Rated input| kW| 0.82| 1.27| 1.60| 1.98| 2.42| 3.05| 3.54| 2.42| 3.05| 3.54
COP| 5.10| 4.90| 5.00| 4.80| 5.00| 4.75| 4.52| 5.00| 4.75| 4.52
Heating A7W45
| Capacity| kW| 4.35| 6.35| 8.00| 9.50| 12.05| 14.25| 16.00| 12.05| 14.25|
16.00
Rated input| kW| 1.14| 1.69| 2.11| 2.60| 3.14| 3.83| 4.42| 3.14| 3.83| 4.42
COP| 3.80| 3.75| 3.80| 3.65| 3.84| 3.73| 3.62| 3.84| 3.73| 3.62
Heating A7W55
| Capacity| kW| 4.40| 6.00| 7.40| 9.00| 12.00| 14.00| 16.00| 12.00| 14.00|
16.00
Rated input| kW| 1.49| 2.03| 2.38| 3.00| 3.85| 4.65| 5.49| 3.85| 4.65| 5.49
COP| 2.95| 2.96| 3.11| 3.00| 3.12| 3.01| 2.91| 3.12| 3.01| 2.91
Cooling A35W18
| Capacity| kW| 4.50| 6.00| 8.00| 9.50| 12.00| 13.50| 15.00| 12.00| 13.50|
15.00
Rated input| kW| 0.81| 1.22| 1.67| 2.07| 3.00| 3.60| 4.35| 3.00| 3.60| 4.35
EER| 5.55| 4.92| 4.80| 4.60| 4.00| 3.75| 3.44| 4.00| 3.75| 3.44
Cooling A35W7
| Capacity| kW| 4.50| 6.00| 7.00| 8.00| 11.60| 12.95| 14.30| 11.60| 12.95|
14.30
Rated input| kW| 1.28| 1.93| 2.14| 2.53| 4.20| 4.98| 5.70| 4.20| 4.98| 5.70
EER| 3.50| 3.11| 3.27| 3.16| 2.76| 2.60| 2.51| 2.76| 2.60| 2.51
SCOP2| LWT at 35⁰C| 4.60| 4.65| 5.07| 5.05| 4.77| 4.63| 4.56| 4.77| 4.63| 4.56
LWT at 55⁰C| 3.35| 3.49| 3.47| 3.51| 3.48| 3.43| 3.48| 3.54| 3.46| 3.49
Seasonal space heating energy efficiency| LWT at 35⁰C| A+++
LWT at 55⁰C| A++
Electric heater power input| kW| 3| 3| 3| 3| 3| 3| 3| 6(9)| 6(9)| 6(9)
MOP(Maximum overcurrent protection)3| A| 18| 18| 19| 19| 32| 32| 32| 14| 14|
14
MCA( Minimum circuit amps)| A| 12| 14| 16| 17| 25| 26| 27| 10| 11| 12
Compressor| Type| Twin rotary DC inverter
Outdoor fan
| Motor type| Brushless DC motor
Number of fans| 1
Throttle type| Electronic expansion valve
Air side heat
exchanger
| Type| Finned tube
Water-side heat exchanger| Type| Plate type
Refrigerant
| Type| R32
Factory charge| kg| 1.30| 1.30| 1.40| 1.40| 1.74| 1.74| 1.74| 1.74| 1.74| 1.74
Sound power Level4| dB| 56| 59| 60| 61| 64| 66| 68| 64| 66| 68
Sound pressure level5| dB| 44| 46| 47| 50| 53| 54| 55| 53| 54| 55
Net dimensions (W×H×D)| mm| 1220×709×390| 1293×860×495
Packing dimension (W×H×D)| mm| 1315×844×430| 1395×996×535
Net/Gross weight| kg| 76.0/87.0| 76.0/87.0| 95.0/116.0| 95.0/116.0|
112.0/133.0| 112.0/133.0| 112.0/133.0| 124.0/145.0| 124.0/145.0| 124.0/145.0
Piping connections| R1″| R1″| R5/4″| R5/4″| R5/4″| R5/4″| R5/4″| R5/4″| R5/4″|
R5/4″
Operation range
| Cooling| ⁰C| – 5~ 43
Heating| ⁰C| – 25~ 35
DHW| ⁰C| – 25~ 43
Water outlet
| Cooling| ⁰C| 5 ~ 20
Heating| ⁰C| 25 ~ 65
DHW| ⁰C| 20 ~ 60
Abbreviations:
- DHW: Domestic hot water
- LWT: Leaving water temperature
Notes
- Relevant EU standards and legislation: EN14511; EN14825; EN50564; EN12102; (EU) No 811/2013; (EU) No 813/2013; OJ 2014/C 207/02.
- Seasonal space heating energy efficiency class tests in average climate conditions.
- Sound power test condition :EN12102- 1.
- Sound pressure level is the maximum value tested under the two conditions of A7W35 and A35W18.
Split product parameters
Model name
| THF-4D/ HBpO-A| THF-6D/ HBpO-A| THF-8D/ HBpO-B| THF-10D/ HBpO-B| THF-12D/
HBpO-A| THF-14D/ HBpO-A| THF-16D/ HBpO-A| THF-12S/ HBpO-A| THF-14S/ HBpO-A|
THF-16S/ HBpO-A
---|---|---|---|---|---|---|---|---|---|---
Power supply| V/Ph/Hz| 220-240/1/50| 220-240/1/50| 220-240/1/50| 380-415/3/50
Heating A7W35| Capacity| kW| 4.20| 6.22| 8.00| 9.50| 12.10| 14.50| 16.00|
12.10| 14.50| 16.00
Rated input| kW| 0.82| 1.27| 1.60| 1.98| 2.42| 3.05| 3.54| 2.42| 3.05| 3.54
COP| 5.10| 4.90| 5.00| 4.80| 5.00| 4.75| 4.52| 5.00| 4.75| 4.52
Heating A7W45| Capacity| kW| 4.35| 6.35| 8.00| 9.50| 12.05| 14.25| 16.00|
12.05| 14.25| 16.00
Rated input| kW| 1.14| 1.69| 2.11| 2.60| 3.14| 3.83| 4.42| 3.14| 3.83| 4.42
COP| 3.80| 3.75| 3.80| 3.65| 3.84| 3.73| 3.62| 3.84| 3.73| 3.62
Heating A7W55| Capacity| kW| 4.40| 6.00| 7.40| 9.00| 12.00| 14.00| 16.00|
12.00| 14.00| 16.00
Rated input| kW| 1.49| 2.03| 2.38| 3.00| 3.85| 4.65| 5.49| 3.85| 4.65| 5.49
COP| 2.95| 2.96| 3.11| 3.00| 3.12| 3.01| 2.91| 3.12| 3.01| 2.91
Cooling A35W18| Capacity| kW| 4.50| 6.00| 8.00| 9.50| 12.00| 13.50| 15.00|
12.00| 13.50| 15.00
Rated input| kW| 0.81| 1.22| 1.67| 2.07| 3.00| 3.60| 4.39| 3.00| 3.60| 4.39
EER| 5.55| 4.92| 4.80| 4.60| 4.00| 3.75| 3.42| 4.00| 3.75| 3.42
Cooling A35W7| Capacity| kW| 4.50| 6.00| 7.00| 8.00| 11.60| 12.95| 14.30|
11.60| 12.95| 14.30
Rated input| kW| 1.28| 1.93| 2.14| 2.53| 4.20| 4.98| 5.70| 4.20| 4.98| 5.70
EER| 3.50| 3.11| 3.27| 3.16| 2.76| 2.60| 2.51| 2.76| 2.60| 2.51
SCOP2| LWT at 35⁰C| 4.60| 4.65| 5.07| 5.05| 4.78| 4.63| 4.56| 4.70| 4.58| 4.56
LWT at 55⁰C| 3.35| 3.49| 3.47| 3.51| 3.48| 3.47| 3.48| 3.48| 3.35| 3.44
Seasonal space heating energy efficiency class2| LWT at 35⁰C| A+++
LWT at 55⁰C| A++
MOP(Maximum overcurrent protection)3| A| 18| 18| 19| 19| 32| 32| 32| 14| 14|
14
MCA( Minimum circuit amps)| A| 12| 14| 16| 17| 25| 26| 27| 10| 11| 12
Compressor| Type| Twin rotary DC inverter
Outdoor fan| Motor type| Brushless DC motor
Number of fans| 1
Throttle type| Electronic expansion valve
Air side heat exchanger| Type| Finned tube
Refrigerant
| Type| R32
Factory charge| kg| 1.30| 1.30| 1.65| 1.65| 1.84| 1.84| 1.84| 1.84| 1.84| 1.84
Sound power level4| dB| 56| 59| 60| 61| 64| 66| 68| 64| 66| 68
Sound pressure level5| dB| 44| 46| 47| 50| 53| 54| 55| 53| 54| 55
Net dimensions (W×H×D)| mm| 845×700×375| 1010×860×494
Packed dimensions(W×H×D)| mm| 960×732×400| 1135×970×530
Net/Gross weight| kg| 45.5/48.0| 45.5/48.0| 62.0/75.0| 62.0/75.0| 78.0/90.5|
78.0/90.5| 78.0/90.5| 90.0/102.5| 90.0/102.5| 90.0/102.5
Piping connections
| Type| | Flare| Flare| Flare| Flare| Flare| Flare| Flare| Flare| Flare|
Flare
Liquid Dia.| mm| Φ6.35| Φ6.35| Φ9.52| Φ9.52| Φ9.52| Φ9.52| Φ9.52| Φ9.52|
Φ9.52| Φ9.52
Gas Dia.| mm| Φ15.9| Φ15.9| Φ15.9| Φ15.9| Φ15.9| Φ15.9| Φ15.9| Φ15.9| Φ15.9|
Φ15.9
Min. pipelength| m| 2| 2| 2| 2| 2| 2| 2| 2| 2| 2
Max. pipe length| m| 30| 30| 30| 30| 30| 30| 30| 30| 30| 30
Installation height
| Outdoor unit above| m| 20| 20| 20| 20| 20| 20| 20| 20| 20| 20
Outdoor unit below| m| 20| 20| 20| 20| 20| 20| 20| 20| 20| 20
Operating range
| Cooling| ⁰C| – 5 ~ 43
Heating| ⁰C| – 25 ~ 35
DHW| ⁰C| – 25 ~ 43
Notes
- Relevant EU standards and legislation: EN14511; EN14825; EN50564; EN12102; (EU) No 811:2013; (EU) No 813:2013; OJ 2014/C 207/02:2014.
- Seasonal space heating energy efficiency class tested in average climate conditions.
- Test standard: EN12102- 1.
- The sound pressure level is the maximum value tested under the two conditions of A7W35 and A35W18.
Model name
| SMKLd- 4(6)D/3HBp- A| SMKLd- 8(10)D/3HBp- B| SMKLd- 12(14,16)D/3HBp-A
---|---|---|---
Function| Heating and cooling
Water outlet
| Cooling| ℃| 5 to 20
Heating| ℃| 25 to 65
DHW| ℃| 20 to 60
Power supply| V/Ph/Hz| 220-240/1/50| 220-240/1/50| 220-240/1/50
Electric heater power input| kW| 3| 3| 3
Sound power level1| dB| 38| 42| 44
Sound pressure level(1m)2| dB| 28| 30| 32
Net dimensions (W×H×D)| mm| 420×790×270
Packed dimensions (W×H×D)| mm| 530×1035×355
Net/gross weight| kg| 44.0/50.0| 41.0/47.0| 42.0/48.0
Water circuit
| Piping connections| inch| R1″
Safety valve set pressure| Mpa| 0.3
Drainage pipe connection| mm| DN25
Expansion tank
| Volume| L| 8
Max. water pressure| MPa| 0.3
Pre-pressure| Mpa| 0.1
Heat exchanger| Type| Plate type
water pump head| m| 9
Refrigerant circuit
| Liquid Dia.| mm| Φ6.35| Φ9.52| Φ9.52
Gas Dia.| mm| Φ15.9| Φ15.9| Φ15.9
Excessive operating refrigerant pressure| MPa| 4.3| 4.3| 4.3
Operating temperature range| Ambient temperature| ⁰C| +5~ +35
Water pressure| MPa| 0.1 ~ 0.3
Notes
- Test standard: EN12102- 1.
- The sound pressure level is the maximum value tested under the two conditions of Note3 and Note4 for different combination between outdoor unit and hydronic box..
- Outdoor air temperature 7℃ DB, 85% R.H.; EWT 30℃, LWT 35℃.
- Outdoor air temperature 35℃ DB; EWT 23℃, LWT 18℃.
Versatility
Heating, cooling, and hot water with complete solutions, to the creative
life
Tri-thermal is an integrated system that provides space heating and cooling as
well as domestic hot water, offering a complete, all-year-round solution that
can remove the need for traditional gas or oil boilers, or work together with
them.
High Efficient and energy-saving
Well-known brand DC inverter compressor(GMCC)
High-reliability electrical design
- High-current resistant& high-temperature resistant
Large pressure ratio design
- Low suction pressure
- High exhaust pressure
- Heating at low ambient temperature
Low oil output design
- Optimized internal tank design
- Less lubricating oil required
- Effectively solves the problem of oil return
DC Inverter motor design
- High efficiency, the highest SCOP is 5.07
Low noise vibration design
- Vibration optimization of twin rotor
- Noise optimization of double-layer mufflers
High-reliability volume design
- Large oil storage space
- Suitable for use in partial load conditions and long-pipe
High-efficient L-type heat exchanger
- Adopting advanced 3-D dynamic analysis and cross-flow path design, air volume increased by 8%, and heat exchange was more efficient.
Internal thread heat transfer pipe
- Using hydrophilic anti-corrosive fins, heat transfer efficiency increased 6%.
Corrugated fin
- Applying inner thread tube with 10% higher heat exchange efficiency.
Stepless inverter fan motor
- Realize stepless speed regulation, and reduce power consumption by 20% compared with AC motors
- Original built-in drive, high motor efficiency, more reliable
- Stepless regulation of air volume, precise control
- Quiet operation
- Insulation grade E
Plate heat exchanger
- Withstand high temperature and high pressure
- Compact design, smaller volume, and less pressure drop
- High anti-corrosion performance
- High thermal efficiency and lower fouling factor
- Easy installation and maintenance
- Under the same pressure loss, the heat transfer coefficient of the plate heat exchanger is 3~5 times higher than that of the tubular heat exchanger, covering an area of 1 / 3 of the tubular heat exchanger.
Multiple certifications
Environmental friendly refrigerant
- The GWP of R32 is 675
- CO2 equivalent is decreased 68% compared with R410a
- Save clients energy and protect the environment
Safe and Comfort
Anti-bacteria mode
- Designed to guarantee our safety and health.
- It works by heating the water to about 70 degrees.
Provide DHW in time
Water pump
- Running smoothly
Electrical heater
- Heat DHW quickly
- As a back-up facility for inclement weather
Solar kit heater
- Energy saving
Low level of noise
- Multiple silent modes are optional Silent mode, night silent mode, and super silent mode.
- Optimized right & back side plates design Based on the 3-D simulation, which greatly decrease the vibration and running noise.
3-zone control
- Connect max 3 zones at the same time and achieve different temperature control in different zones.
Intelligent control
Wired controller
- Liquid crystal, two-way communication, backlight at night
- Access to wifi with internet control
- Multiple languages are available
- Can set the parameters and query for faults
- Daily schedule and weekly schedule accurately control time and operation mode to prevent forgetting
APP controller
- Modes adjustment
- Cascade control
- Power consumption record
- Sanitory hot water priority mode
- Unit status & fault information display
- Temp, Pump flow rate, timer setting etc.