SCUDO KoGE 4 in 1 Chrome Swan Pull Out Spout Boiling Water Tap
Introduction
Please ensure this guide and instructions is fully read and understood prior
to installation or operation of the product.
It is assumed due to the installation requirements; and risk of injury should
the product be installed incorrectly. Installation is completed by a qualified
competent person.
Intended Use
The Koge boiling water system, comprising the tap, boiling unit, and filter,
is intended for indoor use only.
This system is designed to provide instant boiling water for various domestic
applications.
Important Notice
This product uses a submerged element to heat the water. The product must not
be plugged in until the tank is full of water. Operating dry will cause the
element to burn out instantly.
Make sure all electrical connections must with building regulations.
Make sure all water connections comply with building regulations.
Compatability & Warranty
To ensure safety and warranty coverage, it is imperative that all components
of this hot water system is provided by Koge from Scudo. Mixing products from
other suppliers pose a potential safety hazard and will void the warranty.
Environmental Conditions
The system boiling unit should be placed in an environment with low humidity
levels. All precautions should be taken to prevent exposure to freezing
temperatures. This will prevent damage to the components and effect
functionality.
Environmental temperatures above 35OC may cause the product to overheat.
Boiler Unit Positioning
The unit must be placed upright on a flat surface; the unit must not be
covered to allow adequate ventilation. Any deviation from this may result in
operational issues and could compromise safety.
The boiler unit is not serviceable, do not attempt to open the casing or
tamper with the power supply cable, in the event of a fault.
Filter Maintenance
To ensure the quality and safety of the dispensed water, the filter provided
with the system must always be used and replaced at least every 6 months.
Failure to do so may affect water quality and void the warranty. Only Koge
replacement filters supplied directly from Scudo will maintain the product
warranty (proof of purchase will be required).
Replacement Filters can be purchased here: www.scudo.co.uk/spares
Open Vent
This product uses an open vent pipe to elevate pressure during the boiling
process, it is important all means necessary to prevent the ventilation pipe
from being blocked, twisted or kinked.
Installation Requirements
Electrical Requirements
A standard 220/240v 50Hz earthed 13amp switched electrical socket is required.
This must be placed within reach of the boiler unit 13amp plug. Cable length
is 110cm. Extension cables should not be used.
Please ensure that the circuit has available capacity for the 1.5kw power requirement. We recommend contacting a qualified electrician prior to installation. Failure to check may result in circuit overload, tripping of the RCD, or other electrical hazards.
The boiling unit is supplied with a moulded plastic plug and lead, ensure that this is not cut or tampered with.
Under no circumstance should the boiler casing be removed contact the supplier.
Do not under any circumstance plug in the appliance unless the system is fully primed with water.
Water Supply Requirements
Incoming hot and cold-water feeds should be installed with local accessible
isolation close to the boiler unit. Warning do not include additional
isolation to boiling unit beyond the inlet connection, this risks
unintentional pressurization.
It is recommended to fully flush the plumbing system prior to installation of the boiling water system, debris left might affect product function.
Ventilation Requirements
To avoid overheating or damaging electronic components, a zone of 10-15cm
around the boiling unit is required around 3 sides of the unit. Humidity
should not be above 60%, above this risks condensation which may affect
electronic components.
Temperature Requirements
The product should only be used in an indoor environment. All preventative
action should be taken to sure the product is not subject to ambient
temperatures below 0OC or above 35OC. Should this be unavoidable the product
should be electrically isolated, and the tank emptied.
Altitude Adjustment
Please note the product should never be allowed to reach boiling point, i.e.
100OC at sea level. Installations at higher elevations should take potential
changes to the boiling point and adjust the maximum temperature to a minimum
of 2OC below.
Prolonged Inactivity
Should the product be subject to prolonged periods of no use it is recommended
to turn the boiler unit off, isolate the power supply and drain the tank.
Flow Rate| 1/2 Bar| 1 Bar| 1 1/2 Bar| 2 Bar| 3
Bar
---|---|---|---|---|---
Cold Water| 4.0L| 5.8L| 7.0L| 8.2L| 10.2L
Hot Water| 4.0L| 5.8L| 7.0L| 8.2L| 10.2L
Mixer Water| 5.4L| 7.7L| 9.2L| 10.8L| 13.1L
Boiling Water| 0.8L| 0.9L| 1.3L| 1.5L| 1.8L
Parts List
N° | Description | QTY |
---|---|---|
A | Tap | 1 |
B | O-Ring | 1 |
C | Rubber Washer | 1 |
D | Metal Washer | 1 |
E | Mounting Nut | 1 |
F | Flex Hose Adaptor (3/8 to 1/2 thread) | 1 |
1 | Cold Flexible Hose | 1 |
2 | Hot Flexible Hose | 1 |
3 | Hose from Filter Outlet to Tap | 1 |
4 | Hose from Tap to T Adaptor | 1 |
5 | Hose from Tap to T Adaptor | 1 |
6 | Hose from Tap to Boiler Unit | 1 |
7 | Hose from Boiler Unit to Main Hose | 1 |
8 | Hose from Cold Outlet to Filter Inlet | 1 |
10 | Outlet Connector 3/8 | 1 |
11 | Flex Hose Adapter (3/8 to 1/2 thread) | 2 |
12 | T Adapter | 1 |
Installation Diagram
Installation Instructions
-
Slide the Rubber gasket (C) first, Metal washer (D) second, then the mounting nut (E) over the hoses onto the stem.
-
Use a Phillips head screwdriver to thread the 2 screws.
-
Connect the Cold flexible hose (1) & T Adapter (11) onto the cold matching water valves and secure the connection with a spanner.
-
Connect the Hot flexible hose (2) onto the hot matching water valve, and secure the connection with a spanner.
-
Connect hose (8) onto the other end of T Adaptor (11), and the other end of the hose fitted onto the filter inlet. Then secure the connection.
-
Before inserting the hose into filter inlet, remove the blue tab and replace once the hose is connected.
-
Remove blue tab. Connect hose (3) onto the filter outlet, then secure the connection. Reinsert the blue tab.
-
Before plugging in the boiling unit, ensure to fill the tank fully and run the water for an additional minute. Plug in the boiling unit and turn on the power.
How to Use your 4-1 Boiling Water Tap
- For filtered hot water, press the left handle button. Keep the button pressed and rotate the handle anti-clockwise for instant hot water.
- For filtered cold water, press the left handle button. Keep the button pressed and rotate the handle clockwise for filtered cold water.
- For mixed water, pull the large lever backwards for mains hot water and forwards for mains cold water dispensing.
Regulation Requirements
It is important to ensure that the water supply to your tap is connected in accordance with the water regulation requirements, plumbing code and good plumbing practice. It is good practice that the supply of hot and cold water to the tap are equal (balanced) pressure in order to provide a consistent flow. Water supply should be from a common source, either mains or tank fed. If the water supply is not equal pressure then a Non Return Valve (check valve) should be fitted on the hot inlet.
Water Supply Pressures
The tap has been designed to function under the following conditions:
- Minimum supply pressure for cold water is 1.5 bar.
- Maximum supply pressure 5 bar (although we only recommend a maximum supply pressure of 3 bar).
IMPORTANT
Care & Maintenance of the Tap
Only clean the tap with a soft cloth, warm water and a mild detergent solution. Rinse the tap clean thoroughly afterwards with water. Do not use any abrasive or harsh chemical products, otherwise this will invalidate your guarantee.
These instructions are only intended as a guide, if there is any doubt then contact a certified plumber or service agent and avoid using the Instant Hot Water System until has been checked.
Boiling Water Tank
To switch the instant hot water heater on or off
Hold the “On/Off” key (A) once to switch the water heater on. Hold the
“On/Off” key (A) once again at any time to switch the water heater off.
To set the water temperature
Touch the “Temperature” key (B) several times to scroll through the available
temperatures:
45OC / 55OC / 65OC / 75OC / 85OC / 90OC / 91OC / 92OC / 93OC / 94OC / 95OC /
96OC / 97OC / 98OC
Once you had decided the desired temperature, leave it and the indicator will
flash 3 times. The boiling unit is now set to the desired temperature.
Note
At all times, the “Actual Temperature” indicator (C) shows the actual
temperature of the water in the heater unit reservoir.
When the boiling unit drops 5OC below the desired temperature, the unit will begin heating up again.
A: On/Off Key
B: Temperature Key
C: Heating Display
Troubleshooting
Below is a list of some of the possible malfunctions.
If the problem cannot be resolved as described, contact your dedicated KoGE retailer.
Problem | Possible Cause | Remedy |
---|---|---|
“Set Temperature” indicator flashes “E3”. | Insufficient water in the tank. |
Prime the installation as described in the installation instructions.
Water and Steam is spitting from the instant hot water tap spout| Unit is
boiling| Turn the instant hot water tap handle on and release the water.
Adjust the water temperature on the display to a lower setting.
Water is not hot| The electronic instant hot water appliance is unplugged.
There has been a power cut. The electronic unit has not been powered up| Make
sure the instant hot water appliance is plugged in and connected to an earthed
electricity outlet. Make sure that the circuit breaker and
fuse are working correctly. Reset the temperature then press the confirm key. Turn on the power and then set the required temperature and confirm the boiler heats up.
Water is not hot| Water temperature setting on display panel is set too high.|
Set the temperature to the required level and confirm the boiler heats up.
Water drips from the instant hot water tap spout| The expansion chamber isn’t
draining the system correctly due to very small draw off of water. The spout
is blocked.| Draw off 0.5L of water to clear and prime the system. avoid
drawing off less that 150ml of water at a time. Remove and clean the aerator
on the tap.
Slow flow from the spout| The water filter may be clogged from impurities in
the inlet mains water.| The water filter must be changed every 6 months.
Failure to do this will void the guarantee.
Water does not flow immediately| The instant hot water tap is designed for
non-pressurized operation so there will be slight delay before the near
boiling water starts to flow.| This is not a fault. Note that after a large
volume of water has been drawn off there may be a slightly longer delay in the
water appearing from the instant hot water spout.
No water flows| Water valves have been turned off. Inlet pipes have become
twisted or blocked.| Turn on all the water valves. Ensure the pipes are not
twisted or kinked and restricting flow. Remove and clean the aerator.
“Set Temperature” indicator flashes “E4”.| Product Catastrophic Failure|
Contact KoGE retailer if under warranty period.
Specifications
Supply | 230V ~ 50Hz |
---|---|
Power | 1.5 kW |
IP Rating | X4 |
Tank Capacity | 2.4 Litres |
Immediate Draw Off | 1.7 Litres |
Minimum Supply Pressure | 0.15 MPa (1.5 Bar) |
Maximum Supply Pressure | 0.5 MPa* (5 Bar) |
Hot & Cold Connections | 1/2” BSP |
Approvals | UKCA CE |
- If the pressure is above 0.5 MPa (5 Bar) then a pressure reducing valve is required.
Guarantee
This product is covered by a standard parts of replacement warranty for a
period of 12 months from the date of purchase. If there is manufacturing
defect within the warranty period we will send spare parts, repair and return
the unit or, at our discretion, supply a replacement product. Incorrect
installation, frost damage, the consequences of limescale deposits or failure
to follow correct operating and miniatous instructions are excluded.