VON DUPRIN 78 Series Rim Device Installation Guide
- September 23, 2024
- VON DUPRIN
Table of Contents
- VON DUPRIN 78 Series Rim Device
- Product Specifications
- Product Usage Instructions
- Frequently Asked Questions
- Installation Instruction
- Special tools needed
- Customer Service
- SCREW CHART
- Installation Instruction
- 499F STRIKE INSTALLATION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 10-24, 1/4″-20 tap
VON DUPRIN 78 Series Rim Device
Product Specifications
- Model Number: 47961351
- Product Name: 47961351 Rim Exit Device
- Device Type: 78 Rim Exit Device
Product Usage Instructions
Installation Instructions:
- Draw horizontal device and strike center lines (CL).
- Align strike on CL and mark the two slotted holes.
- If necessary, prepare cutouts for cylinder or trim.
- Prepare center case mounting holes.
- Adjust tailpiece length if needed.
- Prepare center case support holes.
- If necessary, install cylinder.
- If necessary, cut device.
- Attach center case to door.
- Mark and prepare two holes.
- Install required support screws and center case cover.
- Remove protective film from pushbar.
- Adjust strike as needed.
- Install end cap bracket and end cap.
- Install strike support screw.
Frequently Asked Questions
- Q: What tools are needed for the installation of the 47961351 Rim Exit Device?- A: Special tools needed include #10-24, 1/4-20 tap Drill bits: #7, #25, 1/8, 1/4, 13/32, 1.
 
- Q: How can I lock down the pushbar on non-fire devices?- A: Use the Dogging Key provided with the device to lock down the pushbar.
 
- Q: Where can I find online information on the strikes shown in the instructions?- A: For online information on the strikes shown in the instructions, you can visit the web address provided: alle.co/99Rstrikes.
 
Installation Instruction
- 78 Rim Exit Device
- 78-F (Fire) Exit Device
- CD78 (Cylinder Dogging) Exit Device
- QEL78/-F (Electric Latch Retraction) Exit Deviceated
Special tools needed
- 
10-24, 1/4″-20 tap
- Drill bits: #7, #25, 1/8″, 1/4″, 13/32″, 1″
Customer Service
SCREW CHART
Installation Instruction
- 
Draw horizontal device and strike center lines 
- 
Align strike on and mark the two slotted holes. 
 For online information on the strikes shown below, enter the web address shown.alle.co/99Rstrikes
- 
Prepare 2 holes and install 2 screws 
 See “Screw Chart” on previous page for screw types and sizes
- 
Position template against strike and on and mark door. 
- 
If necessary, prepare cutouts for cylinder or trim. 
- 
Prepare 4 center case mounting holes. 
- 
Prepare 2 center case support holes 
- 
Adjust tailpiece length if needed 
 Make sure tailpiece is installed at correct length for 1-3/4″ thick or 2-1/4″ thick door. If necessary, remove pine tree clip, rotate tailpiece, and reinstall pine tree clip.
- 
If using a cylinder, remove cam and rotate 180º 
 Cam must be in position shown with key removed. If necessary, remove cam screws, place cam is correct position, and reinstall cam screws.
- 
If necessary, install cylinder 
- 
If necessary, cut device 
- 
Attach center case to door 
- 
Mark and prepare two (2) holes 
- 
Install end cap bracket and end cap 
- 
Install required support screws and center case cover 
- 
Adjust strike as needed 
- 
Install strike support screw. 
499F STRIKE INSTALLATION
CD (CYLINDER DOGGING) OPTION
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>
