VON DUPRIN 7847 Concealed Vertical Rod Exit Device Installation Guide
- September 14, 2024
- VON DUPRIN
Table of Contents
- 7847 Concealed Vertical Rod Exit Device
- Product Specifications:
- Installation Instructions:
- Tools Required:
- Hurricane Rated Device Requirements:
- Customer Service:
- Screw Chart:
- Door Preparation Chart:
- Device Cut-outs:
- Latch Cases:
- Q: What tools do I need for installation?
- Q: Where can I find hurricane rated device requirements?
- Q: How can I contact Customer Service for assistance?
- 10-24 x 1″
- 10-24 x 1-1/2″
- 10-24 x 1″
- 10-24 x 3/4″
- 10-24 x 1-1/8″
- 10-16 X 3/8″ Thread cutting
- 10-32 X 1/4″
- 10-24 X 1/2″
- 8-32 X 5/16″
- 10-24 X 1/2″
- 10-24 X 1-1/2″
- 8-18 x 3/8″ Thread cutting
- 25 Drill
- 10-24 tap 13/32″ Drill (trim side)
- 25 Drill #10-24 tap
- 25 drill #10-24 tap,
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 10-24 tap
7847 Concealed Vertical Rod Exit Device
“`html
Product Specifications:
-
Model: 7847/48 Concealed Vertical Rod Exit Device
-
Applications: Metal Doors
-
Devices Covered:
-
7847/48 Concealed Vertical Rod Exit Device
-
7847-F/48-F (Fire) Concealed Vertical Rod Exit Device
-
CD7847/48 (Cylinder Dogging) Concealed Vertical Rod Exit
Device -
QEL7847/48/-F (Electric Latch Retraction) Concealed Vertical
Rod Exit Device -
HH/HW7847/47-F (Hurricane) Concealed Vertical Rod Exit
Device
-
Installation Instructions:
Tools Required:
- 5/64 hex wrench
-
10-24 tap
- Drill bits: #25, 1/4, 13/32, 1/2
Hurricane Rated Device Requirements:
For hurricane rated device requirements, refer to page 4 of the
manual.
Customer Service:
For assistance, contact Customer Service at
1-877-671-7011 or
visit www.allegion.com/us
Screw Chart:
Details on screw sizes and applications are provided in the
manual.
Door Preparation Chart:
Refer to the instructions on the following pages for door
preparation details.
Device Cut-outs:
Instructions on marking and cutting out for metal and wood doors
are provided.
Latch Cases:
Detailed instructions on drilling for latch cases on different
door sizes are included.
Frequently Asked Questions (FAQ):
Q: What tools do I need for installation?
A: You will require a 5/64 hex wrench, #10-24 tap, and drill
bits: #25, 1/4, 13/32, 1/2.
Q: Where can I find hurricane rated device requirements?
A: The hurricane rated device requirements are detailed on page
4 of the manual.
Q: How can I contact Customer Service for assistance?
A: You can reach Customer Service at
1-877-671-7011 or visit
www.allegion.com/us.
“`
47986707
47986707
7847
Concealed Vertical Rod Exit Device Metal Door Applications
Installation Instructions
Devices covered by these instructions:
7847/48 Concealed Vertical Rod Exit Device 7847-F/48-F (Fire) Concealed
Vertical Rod Exit Device CD7847/48 (Cylinder Dogging) Concealed Vertical Rod
Exit Device QEL7847/48/-F (Electric Latch Retraction) Concealed Vertical Rod
Exit Device HH/HW7847/47-F (Hurricane) Concealed Vertical Rod Exit Device
Dogging Key (use with non-fire devices
to lock down pushbar)
Index: · Screw chart ……………………….. 2 · Door preparation chart ………… 3 · Device
installation ……………. 4-6 · Adjust rods ………………………… 7 · Frame preparation chart
………. 7 · Optional equipment ……………. 8 · Cut device ………………………… 8
Special tools needed: 5/64″ hex wrench #10-24 tap Drill bits: #25, 1/4″,
13/32″, 1/2″
For hurricane rated device requirements, see page 4.
Customer Service
1-877-671-7011 www.allegion.com/us
© Allegion 2024 Printed in U.S.A. 47986707 Rev. 08/24-b
SCREW CHART
A
10-24 x 1″
Surface mount or
Sex bolts (1-3/4″ door)
10-24 x 1-1/2″
Sex bolts (2-1/4″ door)
– Packaged with trim #10-24 x 3/4″
10-24 x 1″
785 trims (1-3/4″ door) 785 trims (2-1/4″ door)
B
10-24 x 3/4″
Surface mount or Sex bolts (1-3/4″ door)
10-24 x 1-1/8″
Sex bolts (2-1/4″ door)
C
10-16 X 3/8″ Thread cutting
End cap
D
10-32 X 1/4″
Bracket to latch
E
10-24 X 1/2″
Bracket to door
F
Rod adjusting screw
Retaining clip
G
8-32 X 5/16″
Retaining clip
H
10-24 X 1/2″
338 strike
I
10-24 X 1-1/2″
Ratchet release
J
8-18 x 3/8″ Thread cutting
2
Center case cover
DOOR PREPARATION CHART
Go to instructions on next page before using preparation chart
Ratchet Release Hole
11/16″ 1/2″ Stop height 13/16″ 5/8″ Stop height 15/16″ 3/4″ Stop height
Reinforcing required
Center case – 4 holes
Surface mount *Sex bolts or trims
25 Drill
1/4″ Drill (device side)
10-24 tap 13/32″ Drill (trim side)
X
- Required on Hurricane (HH) devices
CL
CL
*End cap bracket – 2 holes
Surface mount
**Sex bolts
X
25 Drill #10-24 tap
1/4″ Drill (device side) 13/32″ Drill (trim side)
- Prepare holes after lock side of device is mounted and hinge side is equal distance to bottom of door
** Required on Hurricane (HH) devices
Drill 1/2″ dia. hole (inside face of door)
CL Latch
Door Cut-outs
Outside cylinder and trim applications: Mark with template and cut-out: Metal
door (cut device side) Wood door (cut thru)
For all 7847, 7847-F, and HH7847 devices:
Trace cut-outs from plastic template (cut device side only)
Latch Cases
(Drill top and bottom of door)
CL Latch case and device
1-5/8″ 1-5/8″ 1-9/32″ 1-9/32″
Inside face of door
1-3/4″
CL Latch case and device
1-5/8″
Inside face of door
1-9/32″
2-1/4″ 1-3/4″
HH / Fire Device
7/8″
7/8″
CL Latch
case
7/16″ Drill & tap #10-24
2-1/4″
Panic device
7/8″
7/8″ CL Latch
case
7/16″ Drill & tap #10-24
3
HURRICANE RATED DEVICE REQUIREMENTS
Hurricane rated exit device requirements (when used with approved Allegion door applications)
Sexbolts
When installing a Wind and Impact-rated hurricane device (HH), sex bolts must be used. Sex bolts are noted throughout the instructions where applicable. If through-bolting trims are used, these trims are equivalent in function and are used in place of sex bolts.
Application
Single door standard strike
Mullion
Double door standard strike
HH (Wind and
HH7847,
Top: 338
Impact rated)
7847
Bottom: 304L
Top: 338
or
HW (Wind Only)
7847-F
Bottom: 304L
1 Draw Horizontal Device Center Line ( )
3 Prepare Door per Preparation Chart on Page 3
RHR shown (LHR opposite)
LC
3t9o-5fi/n8i”sflhoeodr
See trim instructions for pull side door preparation. Line X-X in trim instructions is same as device CL
2 Determine Correct Backset, then Mark 4 Holes for
Device Center Case Using Template
Mark centerline using measuring tape. Place template on centerline mark.
7847 (non-fire rated device) single or double door
7847-F (fire rated device)
or HH7847 (hurricane rated device)
4 Adjust Tailpiece if Needed
Make sure tailpiece is installed at correct length for 1-3/4″ thick or 2-1/4″
thick door. If necessary, remove pine tree clip, rotate tailpiece, and
reinstall pine tree clip.
CL
2-3/16″ backset
CL
Mark 4 holes 4
CL
2-3/4″ backset
CL
Mark 4 holes
Pine tree clip Tailpiece
1-3/4″ door 2-1/4″ door
5 If Using a Cylinder, Remove Cam and Rotate 180°
Cam must be in position shown with key removed. If necessary, remove cam
screws, place cam is correct position, and reinstall cam screws.
Standard Orientation with key removed.
Rotate cam if necessary as shown here.
8 Assemble Rods and Latches and Adjust Length for
Proper Door Height
Follow red and blue instruction cards on rods to set initial rod length
Top length
Fine tune the overall length by threading latch in or out
of rod
For NL and E-trims, use this orientation.
6 If Necessary, Install Cylinder.
Bottom length
1-1/8 – 1-1/4″ (29-32 mm)
1-3/8 – 1-1/2″ (35-38 mm)
9 Install Rods and Latches as Shown
Note: Fire / HH devices use brackets on both sides of latches
Top rod
E
& latch
Bottom rod & latch
D
7 If Using a Cylinder with a Tailpiece, Prepare Device
and Cylinder
a. Install tailpiece guide.
Tailpiece guide Trim output tailpiece
Top rod
Bottom rod
F
Device aligns with mounting holes which were
prepared in step 3.
G
5
10 12 Secure Device to Door as Shown, then Hang Door
Install Bottom Strike or Prepare Threshold
on Frame
See “Screw Chart” on page 2 for screw
types and sizes
A
385-A bottom strike 1/4″ undercut for 7847
CL STRIKE
1″
2″ Minimum clearance (with end cap removed) If device is too long for door,
see “Cut Device”
on back cover
Center case
Trim (optional)
Threshold application
1-1/8″
3/8″ 9/16″
Latch case CL
1-1/8″
Stop
3/32″ R max.
2 3/4″
Flat threshold application
Remove material as necessary to accommodate 5/8″ latch bolt throw
Mark and prepare B
2 mounting holes and secure screws
(see page 3)
Mounting bracket flush
Device equal height to bottom of door on each end
C
11 Install Top Strike and Ratchet Release
338 Top strike
1/8″
5/8″
304L strike
Grout strike into floor
Hurricane applications use threshold with 304L bottom strike
Bottom latch
304L strike grouted into floor
Threshold
Roller side
Strike
H
See “Frame Preparation” on page 7 for cut-out and holes
338 Strike
13 Adjust Rods and Install Center Case Cover
See “Adjust Rods” on page 7 for adjustment procedure Remove protective film
from pushbar
Roller side Away from door stop
Ratchet release
Center case cover
Spacer (use when frame
Shim
has no door stop)
(if needed)
J
I
See “Frame Preparation” on page 7 for holes
6
ADJUST RODS
1. Open door and release top latch bolt as shown (Figure 1). Top latch bolt
2. Loosen bottom locking screw (Figure 2).
3. Disconnect bottom vertical rod by removing bottom adjusting screw.
4. Loosen top locking screw.
5. Rotate top adjusting screw clockwise until top latch bolt is fully
extended (Figure 1).
6. Check top latch bolt for deadlocking (latch bolt should not push in).
7. Turn top locking screw in. Do not over-tighten
Shown fully extended
Figure 1
Top adjusting
screw Top
locking screw
Figure 2
Bottom locking screw
Bottom adjusting
screw
8. Depress pushbar and release.
9. Make sure top latch bolt stays retracted as shown. Latch bolt retracted
(flush with latch case)
Figure 3
10. Install bottom adjusting screw through bottom rod (Figure 2).
11. With top latch bolt still retracted, adjust bottom rod so latch bolt
clears floor and bottom strike.
Bottom latch bolt (clears floor and strike)
Figure 4
12. Turn bottom locking screw in. Do not over-tighten. 13. Check device
operation by opening and closing door
several times from the outside.
Redo adjustment procedure if : – Top latchbolt is not held retracted – Bottom
latchbolt does not clear floor and bottom strike
FRAME PREPARATION
1″ min.
TOP STRIKE
6″ min.
RATCHET RELEASE
CL Latch case
7/16″
1/8″ Latch bolt CL RHR door
Edge of stop
CLDouble door application
CL Latch bolt LHR door 1-5/16″
21/32″15/16″
13/16″ 1-5/8″
13/32″ 1/4″ dia. 82° csk. x 3/8″ dia. in frame
Inside roller edge
1-7/8″
13/32″
Inside roller edge 15/16″
25 drill #10-24 tap,
2 places
9/16″
1-1/8″
DO NOT USE SLOTS FOR POSITIONING. DRILL HOLES AS INDICATED HERE.
Reinforcing required
Plunger must go thru hole in door.
Adjust so plunger releases latch bolt when
door is closed.
Plunger
7
OPTIONAL EQUIPMENT – CONTINUED
CD (CYLINDER DOGGING)
1. Remove mortise cylinder cam and reinstall in reverse (Figure 6).
2. Insert key and rotate cam to install the cylinder to the cover plate (Figure 7).
3. Remove key to slide cover plate in position in the mechanism case.
Offset toward pushbar
Std. mortise cylinder
Std. mortise cylinder
Dogging plate cover
Mortise cylinder
cam
Mortise cylinder
cam CD function conversion
Figure 6
Dogging procedure
Turn cylinder key clockwise approx. 1/8 turn for standard dogging
Depress pushbar
Cylinder locating washer
Figure 7
Std. mortise cylinder
Cylinder collar
Cylinder lock nut Mechanism
case
CUT DEVICE
1 Measure amount to cut off device.
Device aligned with mounting
holes
2 Tape and mark area being cut.
Remove anti-rattle clip Tape
2″ Minimum clearance (with endcap removed)
5/16″
Note
If 5/8″ diameter wire access hole has been predrilled in door, cut device
5/16″ from center of hole.
3 Cut device square.
Cut device square NOTE: Device must
and remove all be cut square for
burrs
proper end cap fit
Cover plate (flush to pushbar)
Pushbar
4 Slide anti-rattle clip into device.
2″
min.
Anti-rattle
clip inside
8
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>