VON DUPRIN 47981500 75 Series Rim Exit Device Instruction Manual
- September 22, 2024
- VON DUPRIN
Table of Contents
VON DUPRIN 47981500 75 Series Rim Exit Device
Specifications :
- Product Name: 47981500 Rim Exit Device
- Series: 75 Series
- Devices Covered: 75 Rim Exit Device, 75-F Rim Exit Device, CD75 Rim Exit Device, QEL75/-F Rim Exit Device
Product Usage Instructions
Installation Instructions:
Special tools needed: #10-24 and 1/4-20 tap Drill bits: #7, #25, 1/8, 1/4,
5/16, 13/32, 1/2
Device Subassembly:
Follow the screw chart provided for proper screw types and sizes during
assembly.
Installation Steps:
- Draw horizontal device and strike center lines.
- Install strike using two screws only at this time.
- Prepare frame for strike using paper templates.
- If using a 1439 strike, install wear strip. If not, proceed to preparing lock side of the door for device and trim.
- Measure to determine the length to cut the device.
- If necessary, cut the device following instructions for cutting and securing mounting bracket.
- If using a cylinder with a tailpiece, prepare the device and cylinder accordingly.
FAQ :
-
Q: What tools are required for installation?
A: #10-24 and 1/4-20 tap Drill bits: #7, #25, 1/8, 1/4, 5/16, 13/32, 1/2 -
Q: How do I prepare the frame for the strike?
A: Refer to the provided paper templates for strike templates and frame preparation dimensions. -
Q: How do I align the device for cutting?
A: Measure to determine the length to cut the device ensuring a minimum clearance of 1-3/16 inches with the end cap removed. Align the device with mounting holes and mark a vertical line for trim alignment.
75 Series
Devices covered by these instructions: 75 Rim Exit Device
75-F Rim Exit Device
CD75 Rim Exit Device
QEL75/-F Rim Exit Device
Rim Exit Device
Installation Instructions
Customer Service
1-877-671-7011 www.allegion.com/us
© Allegion 2024 Printed in U.S.A. 47981500 Rev. 04/24-a
SCREW CHART
-
Draw horizontal device and strike center lines (CL).
-
Prepare frame for strike using paper templates.
See pages 9 and 10 for strike templates and frame preparation dimensions. L See “Screw Chart” on previous page for screw types and sizes. -
Install strike using two screws only at this time.
Panic Device
Fire Rated Device -
If using a 1439 strike, install wear strip. If not, go to step 5.
- Center wear strip on strike as shown.
- Mark and drill 1/8” dia. holes (4 places).
- Install wear strip with flat head drive rivets (4 places) from 1439 strike package.
-
Tape template to door and mark door.
Note : Line X-X is a reference line on the paper template used for trim and exit device alignment. Line X-X shown here should correspond to line X-X in the trim installation instructions -
Prepare lock side of door for device and trim.
-
Measure to determine length to cut device.
Note
If 5/8” diameter wire access hole has been predrilled in door, cut device 5/16” from center of hole. -
If necessary, cut device.
-
If using a cylinder with a tailpiece, prepare device and cylinder.
-
Attach center case to door.
-
Install hinge stile mounting bracket.
-
Adjust strike as needed.
-
Install strike support screw.
-
Install 2 support screws and center case cover
-
Install 2 support screws and center case cover
499F STRIKE INSTALLATION
- Prepare and install screws through two strike slots.
- Install strike hook and additional strike screws.
- Template aligns as shown.
OPTIONAL EQUIPMENT
CD (Cylinder Dogging) Option
1439 Strike
Frame Preparation
299/299F/1606 Strike
Template
References
Read User Manual Online (PDF format)