VON DUPRIN 47981500 75 Series Rim Exit Device

Specifications :

  • Product Name: 47981500 Rim Exit Device
  • Series: 75 Series
  • Devices Covered: 75 Rim Exit Device, 75-F Rim Exit Device, CD75 Rim Exit Device, QEL75/-F Rim Exit Device

Product Usage Instructions

Installation Instructions:
Special tools needed: #10-24 and 1/4-20 tap Drill bits: #7, #25, 1/8, 1/4, 5/16, 13/32, 1/2

Device Subassembly:
Follow the screw chart provided for proper screw types and sizes during assembly.

Installation Steps:

  1. Draw horizontal device and strike center lines.
  2. Install strike using two screws only at this time.
  3. Prepare frame for strike using paper templates.
  4. If using a 1439 strike, install wear strip. If not, proceed to preparing lock side of the door for device and trim.
  5. Measure to determine the length to cut the device.
  6. If necessary, cut the device following instructions for cutting and securing mounting bracket.
  7. If using a cylinder with a tailpiece, prepare the device and cylinder accordingly.

FAQ :

  • Q: What tools are required for installation?
    A: #10-24 and 1/4-20 tap Drill bits: #7, #25, 1/8, 1/4, 5/16, 13/32, 1/2

  • Q: How do I prepare the frame for the strike?
    A: Refer to the provided paper templates for strike templates and frame preparation dimensions.

  • Q: How do I align the device for cutting?
    A: Measure to determine the length to cut the device ensuring a minimum clearance of 1-3/16 inches with the end cap removed. Align the device with mounting holes and mark a vertical line for trim alignment.

75 Series
Devices covered by these instructions: 75 Rim Exit Device
75-F Rim Exit Device
CD75 Rim Exit Device
QEL75/-F Rim Exit Device

Rim Exit Device

Installation Instructions

Customer Service

1-877-671-7011 www.allegion.com/us

© Allegion 2024 Printed in U.S.A. 47981500 Rev. 04/24-a

SCREW CHART

  1. Draw horizontal device and strike center lines (CL).

  2. Prepare frame for strike using paper templates.
    See pages 9 and 10 for strike templates and frame preparation dimensions. L See “Screw Chart” on previous page for screw types and sizes.

  3. Install strike using two screws only at this time.
    Panic Device
    Fire Rated Device

  4. If using a 1439 strike, install wear strip. If not, go to step 5.

    • Center wear strip on strike as shown.
    • Mark and drill 1/8” dia. holes (4 places).
    • Install wear strip with flat head drive rivets (4 places) from 1439 strike package.
  5. Tape template to door and mark door.
    Note : Line X-X is a reference line on the paper template used for trim and exit device alignment. Line X-X shown here should correspond to line X-X in the trim installation instructions

  6. Prepare lock side of door for device and trim.

  7. Measure to determine length to cut device.
    Note
    If 5/8” diameter wire access hole has been predrilled in door, cut device 5/16” from center of hole.

  8. If necessary, cut device.

  9. If using a cylinder with a tailpiece, prepare device and cylinder.

  10. Attach center case to door.

  11. Install hinge stile mounting bracket.

  12. Adjust strike as needed.

  13. Install strike support screw.

  14. Install 2 support screws and center case cover

  15.  Install 2 support screws and center case cover

499F STRIKE INSTALLATION

  1. Prepare and install screws through two strike slots.
  2. Install strike hook and additional strike screws.
  3. Template aligns as shown.